Elisabet A. Rank

Elisabet A. Rank

Auto-generated profile, based on publicly available information

Elisabet A. Rank

Medizinische Univ. Wien (Austria)

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
5 January 2021 in Light: Science & Applications
Verified
Journal Article
Open access
PDF file
ERElisabet A. Rank
Elisabet A. Rank
RSRyan Sentosa
Ryan Sentosa
DHDanielle Harper
Danielle Harper
MSMatthias Salas
Matthias Salas
AGAnna Gaugutz
Anna Gaugutz
WDWolfgang Drexler
Wolfgang Drexler
In this work, we present a significant step toward in vivo ophthalmic optical coherence tomography and angiography on a photonic integrated chip. The diffraction gratings used in spectral-domain optical coherence tomography can be replaced by photonic integrated circuits comprising an arrayed waveguide grating. Two arrayed waveguide grating designs with 256 channels were tested, which enabled the first chip-based optical coherence tomography and angiography in vivo three-dimensional human retinal measurements. Design 1 supports a bandwidth of 22 nm, with which a sensitivity of up to 91 dB (830 µW) and an axial resolution of 10.7 µm was measured. Design 2 supports a bandwidth of 48 nm, with which a sensitivity of 90 dB (480 µW) and an axial resolution of 6.5 µm was measured. The silicon nitride-based integrated optical waveguides were fabricated with a fully CMOS-compatible process, which allows their monolithic co-integration on top of an optoelectronic silicon chip. As a benchmark for chip-based optical coherence tomography, tomograms generated by a commercially available clinical spectral-domain optical coherence tomography system were compared to those acquired with on-chip gratings. The similarities in the tomograms demonstrate the significant clinical potential for further integration of optical coherence tomography on a chip system.

20 October 2021 in Journal of Biomedical Optics
Verified
Journal Article
Open access
PDF file
Rainer LeitgebRainer Leitgeb
Rainer Leitgeb
FPFabian Placzek
Fabian Placzek
ERElisabet A. Rank
Elisabet A. Rank
LKLisa Krainz
Lisa Krainz
Richard HaindlRichard Haindl
Richard Haindl
WDWolfgang Drexler
Wolfgang Drexler
Optical coherence tomography (OCT) is one of the most innovative and successfully translated imaging techniques with substantial clinical and economic impacts and acceptance.1,2 OCT is a non-invasive optical analog to ultrasound (US) with significantly higher resolution (<1  μm) enabling three- and four-dimensional high-speed (>millions of A-scans/s) imaging with tissue penetration of up to 2 mm, closely matching that of conventional histopathology. The year 2021 marks not only the 30th birthday of OCT (assuming its initiation with the Science paper by Huang et al.3 in 1991) but also the 35th birthday of low-coherence interferometry and optical ranging in biological systems.4,5 In the last three decades, more than 75,000 OCT related papers have been published (about two thirds in ophthalmology) with continuous yearly increases of published articles.6 Breaking through the 1000 publications/year barrier was initiated in 2005/2006 with the introduction of spectral domain OCT (SD OCT). In 2020, the OCT-related scientific output was more than 7800 papers, resulting in nearly one paper every single hour on every single day of the year. Extrapolating this publishing performance, a saturation of yearly publication output at about 9500 can be expected around 2030. After 30 years, it is interesting and important to benchmark this performance with other medical imaging techniques:6 multiphoton microscopy (MPM) [including second harmonic generation (SHG) and third harmonic generation (THG)], developed about three decades before OCT,7,8 has about 50,000 publications so far; photoacoustic imaging (PAI), established in the 1970s,9,10 has about 15,000 papers; and confocal microscopy, developed in the 1940s,11,12 has about 145,000. Developed in the 1940s,13 US imaging has contributed to about 160,000 papers; positron emission tomography (PET), initiated in the 1970s,14,15 has about 175,000; computed tomography (CT), developed in the 1930s,16 has about 750,000; and magnetic resonance imaging (MRI), developed in the late 1940s,17 has close to 1,000,000 publications. This dominance in publications of radiology and nuclear medicine imaging technologies is also one of the reasons why medical imaging is, in general, associated with MRI, CT, PET, or US. It is important to note, though, that from a medical imaging market perspective, optical imaging technologies dominate with 66% versus 34% for radiology and nuclear medicine imaging technologies. In addition, in the United States alone, about 450,000 physicians use primarily optical imaging techniques; 60,000 use primarily radiologic imaging; and about 130,000 use both.18

23 November 2018 in Applied Sciences
Verified
Journal Article
Open access
PDF file
DBDaniela Bovenkamp
Daniela Bovenkamp
RSRyan Sentosa
Ryan Sentosa
ERElisabet Rank
Elisabet Rank
MEMikael Erkkilä
Mikael Erkkilä
FPFabian Placzek
Fabian Placzek
Angelika UnterhuberAngelika Unterhuber
Angelika Unterhuber
We present a combination of optical coherence tomography (OCT) and Raman spectroscopy (RS) for improved diagnosis and discrimination of different stages and grades of bladder cancer ex vivo by linking the complementary information provided by these two techniques. Bladder samples were obtained from biopsies dissected via transurethral resection of the bladder tumor (TURBT). As OCT provides structural information rapidly, it was used as a red-flag technology to scan the bladder wall for suspicious lesions with the ability to discriminate malignant tissue from healthy urothelium. Upon identification of degenerated tissue via OCT, RS was implemented to determine the molecular characteristics via point measurements at suspicious sites. Combining the complementary information of both modalities allows not only for staging, but also for differentiation of low-grade and high-grade cancer based on a multivariate statistical analysis. OCT was able to clearly differentiate between healthy and malignant tissue by tomogram inspection and achieved an accuracy of 71% in the staging of the tumor, from pTa to pT2, through texture analysis followed by k-nearest neighbor classification. RS yielded an accuracy of 93% in discriminating low-grade from high-grade lesions via principal component analysis followed by k-nearest neighbor classification. In this study, we show the potential of a multi-modal approach with OCT for fast pre-screening and staging of cancerous lesions followed by RS for enhanced discrimination of low-grade and high-grade bladder cancer in a non-destructive, label-free and non-invasive way.

18 October 2017 in Optics Letters
Verified
Journal Article
Closed access
PDF file
Richard HaindlRichard Haindl
Richard Haindl
SPStefan Preisser
Stefan Preisser
Marco AndreanaMarco Andreana
Marco Andreana
WRWolfgang Rohringer
Wolfgang Rohringer
CSCaterina Sturtzel
Caterina Sturtzel
MLMengyang Liu
Mengyang Liu
This Letter presents a novel dual modality reflection mode optical coherence and photoacoustic microscopy (OC-PAM) system. The optical coherence microscopy modality features a broadband source to accomplish 5 μm axial resolution. The photoacoustic microscopy modality uses a rigid akinetic Fabry–Perot etalon encapsulated in an optically transparent medium, which forms a 2  mm×11  mm translucent imaging window, permitting reflection mode dual modality imaging. After characterization, the OC-PAM system was applied to image zebrafish larvae in vivo, demonstrating its capability in biomedical imaging with complementary optical scattering and absorption contrasts by revealing morphology in the fish larvae.

20 December 2021 in Translational Biophotonics
Verified
Journal Article
Open access
PDF file
ERElisabet A. Rank
Elisabet A. Rank
AAAnja Agneter
Anja Agneter
TSTilman Schmoll
Tilman Schmoll
Rainer LeitgebRainer Leitgeb
Rainer Leitgeb
WDWolfgang Drexler
Wolfgang Drexler
Optical coherence tomography (OCT) has revolutionized ophthalmic diagnosis as a non‐invasive, cross‐sectional imaging technique in the last 30 years and hence is one of the fastest adopted advanced imaging technologies in the history of medicine. A miniaturization of OCT devices would not only reduce size but ideally also reduce costs and therefore create potential new markets. OCT systems based on photonic integrated circuits (PIC) could enable a significant miniaturization of complex systems with high degree of integration as well as low costs of goods. These therefore have a potential to enable portable, cost‐effective, high performing, real handheld OCT devices. This review identifies three main categories towards miniaturized OCT devices: Handheld imaging probes interfaced to a (mobile) base station, compact home/self‐ OCT and PIC‐based OCT. Imaging performance parameters and technical readiness levels of the identified miniaturized OCT systems for (non‐) ophthalmic applications are presented. Special attention is paid to PIC‐based OCT applications and their progress.Picture: First in vivo human retinal tomogram using a PIC‐based subcomponent (arrayed waveguide grating, AWG) of a spectral domain OCT system. Adapted with permission from E. A. Rank et al.,Light Sci Appl.2021,10, 1, CC By 4.0. Copyright © 2021, The Author(s).

22 September 2016 in Journal of Biomedical Optics
Verified
Journal Article
Open access
PDF file
BZBehrooz Zabihian
Behrooz Zabihian
ZCZhe Chen
Zhe Chen
ERElisabet Rank
Elisabet Rank
CSChristoph Sinz
Christoph Sinz
MBMarco Bonesi
Marco Bonesi
MLMengyang Liu
Mengyang Liu
Studies have proven the relationship between cutaneous vasculature abnormalities and dermatological disorders, but to image vasculature noninvasively in vivo, advanced optical imaging techniques are required. In this study, we imaged a palm of a healthy volunteer and three subjects with cutaneous abnormalities with photoacoustic tomography (PAT) and optical coherence tomography with angiography extension (OCTA). Capillaries in the papillary dermis that are too small to be discerned with PAT are visualized with OCTA. From our results, we speculate that the PA signal from the palm is mostly from hemoglobin in capillaries rather than melanin, knowing that melanin concentration in volar skin is significantly smaller than that in other areas of the skin. We present for the first time OCTA images of capillaries along with the PAT images of the deeper vessels, demonstrating the complementary effective imaging depth range and the visualization capabilities of PAT and OCTA for imaging human skin in vivo. The proposed imaging system in this study could significantly improve treatment monitoring of dermatological diseases associated with cutaneous vasculature abnormalities.