Shanshan Shan

Shanshan Shan

Auto-generated profile, based on publicly available information

Shanshan Shan

State Key Laboratory of Radiation Medicine and Protection, School of Radiation Medicine and Protection, Collaborative Innovation Center of Radiological Medicine of Jiangsu Higher Education Institutions, Soochow University, Suzhou, China

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 May 2023 in Magnetic Resonance in Medicine
Verified
Journal Article
Open access
SSShanshan Shan
Shanshan Shan
Yang GaoYang Gao
Yang Gao
PLPaul Z. Y. Liu
Paul Z. Y. Liu
BWBrendan Whelan
Brendan Whelan
Hongfu SunHongfu Sun
Hongfu Sun
DWDavid E. J. Waddington
David E. J. Waddington
Purpose: MRI is increasingly utilized for image‐guided radiotherapy due to its outstanding soft‐tissue contrast and lack of ionizing radiation. However, geometric distortions caused by gradient nonlinearities (GNLs) limit anatomical accuracy, potentially compromising the quality of tumor treatments. In addition, slow MR acquisition and reconstruction limit the potential for effective image guidance. Here, we demonstrate a deep learning‐based method that rapidly reconstructs distortion‐corrected images from raw k‐space data for MR‐guided radiotherapy applications.Methods: We leverage recent advances in interpretable unrolling networks to develop a Distortion‐Corrected Reconstruction Network (DCReconNet) that applies convolutional neural networks (CNNs) to learn effective regularizations and nonuniform fast Fourier transforms for GNL‐encoding. DCReconNet was trained on a public MR brain dataset from 11 healthy volunteers for fully sampled and accelerated techniques, including parallel imaging (PI) and compressed sensing (CS). The performance of DCReconNet was tested on phantom, brain, pelvis, and lung images acquired on a 1.0T MRI‐Linac. The DCReconNet, CS‐, PI‐and UNet‐based reconstructed image quality was measured by structural similarity (SSIM) and RMS error (RMSE) for numerical comparisons. The computation time and residual distortion for each method were also reported.Results: Imaging results demonstrated that DCReconNet better preserves image structures compared to CS‐ and PI‐based reconstruction methods. DCReconNet resulted in the highest SSIM (0.95 median value) and lowest RMSE (<0.04) on simulated brain images with four times acceleration. DCReconNet is over 10‐times faster than iterative, regularized reconstruction methods.Conclusions: DCReconNet provides fast and geometrically accurate image reconstruction and has the potential for MRI‐guided radiotherapy applications.

24 January 2019 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Closed access
SSShanshan Shan
Shanshan Shan
MLMingyan Li
Mingyan Li
FTFangfang Tang
Fangfang Tang
HMHuan Ma
Huan Ma
FLFeng Liu
Feng Liu
SCStuart Crozier
Stuart Crozier
In magnetic resonance imaging (MRI), system imperfections and eddy currents can cause gradient field deviation (GFD), leading to various image distortions such as increased noise, ghosting artefacts and geometric deformation. These distortions can degrade the clinical value of MR images. Generally, non-Cartesian image sequences, such as radial sampling, produce larger gradient deviations than Cartesian sampling, as a result of stronger eddy current-induced gradient delays and phase errors. In this work, we developed a GFD encoding method to reduce image noise and artefacts for radial MRI. In the proposed method, a hybrid norm (combination of L2-L1 norms) optimisation problem was formed, that incorporated a wavelet sub-band adaptive regularisation mechanism. The new approach seeks a regularised solution not only offering corrected images with reduced artefacts and geometric deformation, but also good preservation of anatomical structural details. The new method was evaluated with simulation and experiment at 9.4T MRI. The results demonstrated that the proposed method can provide over 50% noise reduction and 15% artefact reduction compared with the traditional regridding method, suggesting substantially reduced GFD-induced distortions and improved image quality.

21 January 2023 in Physics and Imaging in Radiation Oncology
Verified
Journal Article
Open access
PLPaul Z. Y Liu
Paul Z. Y Liu
SSShanshan Shan
Shanshan Shan
DWDavid Waddington
David Waddington
BWBrendan Whelan
Brendan Whelan
BDBin Dong
Bin Dong
PKPaul Keall
Paul Keall
Magnetic resonance imaging (MRI)-Linac systems combine simultaneous MRI with radiation delivery, allowing treatments to be guided by anatomically detailed, real-time images. However, MRI can be degraded by geometric distortions that cause uncertainty between imaged and actual anatomy. In this work, we develop and integrate a real-time distortion correction method that enables accurate real-time adaptive radiotherapy. The method was based on the pre-treatment calculation of distortion and the rapid correction of intrafraction images. A motion phantom was set up in an MRI-Linac at isocentre (P0 ), the edge (P 1) and just outside (P 2) the imaging volume. The target was irradiated and tracked during real-time adaptive radiotherapy with and without the distortion correction. The geometric tracking error and latency were derived from the measurements of the beam and target positions in the EPID images. Without distortion correction, the mean geometric tracking error was 1.3 mm at P 1 and 3.1 mm at P 2. When distortion correction was applied, the error was reduced to 1.0 mm at P 1 and 1.1 mm at P 2. The corrected error was similar to an error of 0.9 mm at P0 where the target was unaffected by distortion indicating that this method has accurately accounted for distortion during tracking. The latency was 319 ± 12 ms without distortion correction and 335 ± 34 ms with distortion correction. We have demonstrated a real-time distortion correction method that maintains accurate radiation delivery to the target, even at treatment locations with large distortion.

31 July 2019 in Circuits, Systems, and Signal Processing
Verified
Journal Article
Closed access
PDF file
HGHongping Gan
Hongping Gan
SXSong Xiao
Song Xiao
ZZZhimin Zhang
Zhimin Zhang
SSShanshan Shan
Shanshan Shan
Yang GaoYang Gao
Yang Gao

16 October 2024 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
SSShanshan Shan
Shanshan Shan
Yang GaoYang Gao
Yang Gao
DWDavid Waddington
David Waddington
HCHongli Chen
Hongli Chen
BWBrendan Whelan
Brendan Whelan
FLFeng Liu
Feng Liu
MRI-Linac systems require fast image reconstruction with high geometric fidelity to localize and track tumours for radiotherapy treatments. However, B 0 field inhomogeneity distortions and slow MR acquisition potentially limit the quality of the image guidance and tumour treatments. In this study, we develop an interpretable unrolled network, referred to as RebinNet, to reconstruct distortion-free images from B0 inhomogeneity-corrupted k-space for fast MRI-guided radiotherapy applications. RebinNet includes convolutional neural network (CNN) blocks to perform image regularizations and nonuniform fast Fourier Transform (NUFFT) modules to incorporate B0 inhomogeneity information. The RebinNet was trained on a publicly available MR dataset (3300 images) from eleven healthy volunteers for both fully sampled and subsampled acquisitions. 768 grid phantom and 12 human brain images acquired from an open-bore 1T MRI-Linac scanner were used to evaluate the performance of the proposed network. The RebinNet was compared with the conventional regularization algorithm and our recently developed UnUNet method in terms of root mean squared error (RMSE), structural similarity (SSIM), residual distortions, and computation time. Imaging results demonstrated that the RebinNet reconstructed images with lowest RMSE (0.92) at four-time acceleration for simulated brain images. The RebinNet preserved more image details and substantially increased the computational efficiency (3s, ten-fold faster) compared to the conventional regularization methods (30s), and had better generalization ability than the UnUNet method. The proposed RebinNet can achieve rapid image reconstruction and overcome the B 0 inhomogeneity distortions simultaneously, which would facilitate accurate and fast image guidance in radiotherapy treatments.

16 January 2026 in IEEE Transactions on Medical Imaging
Verified
Journal Article
Closed access
JLJin Liu
Jin Liu
QLQing Lin
Qing Lin
ZXZhuang Xiong
Zhuang Xiong
SSShanshan Shan
Shanshan Shan
CLChunyi Liu
Chunyi Liu
Yang GaoYang Gao
Yang Gao
Incoherent k-space undersampling and deep learning-based reconstruction methods have shown great success in accelerating MRI. However, the performance of most previous methods will degrade dramatically under high acceleration factors, e.g., 8× or higher. Recently, denoising diffusion models (DM) have demonstrated promising results in solving this issue; however, one major drawback of the DM methods is the long inference time due to a dramatic number of iterative reverse posterior sampling steps. In this work, a Single Step Diffusion Model-based reconstruction framework, namely SSDM-MRI, is proposed for restoring MRI images from highly undersampled k-space. The proposed method achieves one-step reconstruction by first training a conditional DM and then iteratively distilling this model four times using an iterative selective distillation algorithm, which works synergistically with a shortcut reverse sampling strategy for model inference. Comprehensive experiments were carried out on both publicly available fastMRI brain and knee images, as well as an in-house multi-echo GRE (QSM) subject. Overall, the results showed that SSDM-MRI outperformed other methods in terms of numerical metrics (e.g., PSNR and SSIM), error maps, image fine details, and latent susceptibility information hidden in MRI phase images. In addition, the reconstruction time for a 320×320 brain slice of SSDM-MRI is only 0.45 second, which is only comparable to that of a simple U-net, making it a highly effective solution for MRI reconstruction tasks.