Hulusi Onal

Hulusi Onal

Auto-generated profile, based on publicly available information

Hulusi Onal

Department of Electronics and Communication Engineering, Istanbul Technical University, Istanbul, Turkey

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 March 2023 in IEEE Access
Verified
Journal Article
Open access
HOHulusi Onal
Hulusi Onal
TYTuba Yilmaz
Tuba Yilmaz
MAMehmet Nuri Akinci
Mehmet Nuri Akinci
Microwave hyperthermia (MH) treatment for breast cancer is a research interest due to its capability to initiate cell necrosis in malignant tumor or to enhance the effect of other treatment modalities such as chemotherapy. The goal of MH treatment is to increase temperature of malignant tumor up to 45°C based on the treatment plan; however, microwave energy focusing is a challenging problem and may cause unwanted hotspots on healthy tissues; therefore, there is a need to monitor the temperature. In this paper, an iterative differential microwave imaging algorithm for temperature monitoring is presented. The algorithm is based on Born iterative method (BIM) and Tikhonov regularization. Feasibility of the algorithm is shown by a large computational study using realistic digital breast phantoms via TM z polarized 2-D scattered fields. Also, some results are given for calibrated scattering parameters, which are obtained from both a 3-D electromagnetic simulation program and a simple measurement setup. An approach for selection of matching medium in hyperthermia monitoring applications is also presented. The reconstructions are performed with scattered field data collected at 11 discrete frequency points uniformly taken from the 0.5-1.5 GHz range. For a specific heating scenario in 2-D problem, reconstruction error is lower than 0.3% with ±10% noise on reference dielectric property distribution and 40 dB signal to noise ratio (SNR). The results show that the proposed approach provides up to 3°C and 0.1°C resolution in temperature estimation with ±10% noise on reference dielectric property distribution for 30 dB and 60 dB SNR values, respectively.

18 January 2023 in IEEE Access
Verified
Journal Article
Open access
Semih DoğuSemih Doğu
Semih Doğu
HOHulusi Onal
Hulusi Onal
Tuba Yilmaz YilmazTuba Yilmaz Yilmaz
Tuba Yilmaz Yilmaz
Ibrahim AkdumanIbrahim Akduman
Ibrahim Akduman
MAMehmet Nuri Akinci
Mehmet Nuri Akinci
Qualitative microwave imaging methods provide a fast and accurate reconstruction of the shapes of the targets from scattered electric field measurements. In this paper, a qualitative imaging method, the singular sources method (SSM), is analyzed for two-dimensional transverse magnetic electromagnetic (2D-TM EM) inverse scattering scenarios. The contribution of the paper can be briefly summarized as: (i) The SSM was previously proposed for the far-field scenario, here we extend the SSM in the near field - inhomogeneous background setup. While making the extension each step (which includes an integral equation) is explained by exploiting the linearity and reciprocity principles to give physical insights. (ii) The relation between the electrical parameters of the scatterers and the indicator of SSM is derived. (iii) To analyze the performance of SSM in real-world problems, the proposed method is tested for monitoring hyperthermia treatment problems with a realistic breast model. Obtained results show that the SSM can handle realistic breast phantoms for monitoring hyperthermia problems.

11 March 2025 in Medical & Biological Engineering & Computing
Verified
Journal Article
Open access
PDF file
HOHulusi Onal
Hulusi Onal
EGEnes Girgin
Enes Girgin
Semih DoğuSemih Doğu
Semih Doğu
Tuba Yilmaz YilmazTuba Yilmaz Yilmaz
Tuba Yilmaz Yilmaz
MAMehmet Nuri Akinci
Mehmet Nuri Akinci
This paper presents a computational study for detecting whether the temperature values of the breast tissues are exceeding a threshold using deep learning (DL) during microwave hyperthermia (MH) treatments. The proposed model has a deep convolutional encoder-decoder architecture, which gets differential scattered field data as input and gives an image showing the cells exceeding the threshold. The data are generated by an in-house data generator, which mimics temperature distribution in the MH problem. The model is also tested with real temperature distribution obtained from electromagnetic-thermal simulations performed in commercial software. The results show that the model reaches an average accuracy score of 0.959 and 0.939 under 40 dB and 30 dB signal-to-noise ratio (SNR), respectively. The results are also compared with the Born iterative method (BIM), which is combined with some different conventional regularization methods. The results show that the proposed DL model outperforms the conventional methods and reveals the strong regularization capabilities of the data-driven methods for temperature monitoring applications. Graphical

19 July 2022 in TechRxiv
Verified
Preprint
Open access
PDF file
HOHulusi Onal
Hulusi Onal
MAMehmet Nuri Akinci
Mehmet Nuri Akinci
Tuba Yilmaz YilmazTuba Yilmaz Yilmaz
Tuba Yilmaz Yilmaz
Microwave hyperthermia (MH) treatment for breast cancer is a research interest due to its capability to initiate cell necrosis in malignant tumor or to enhance the effect of other treatment modalities such as chemotherapy. The goal of MH treatment is to increase temperature of malignant tumor up to 45°C based on the treatment plan; however, microwave energy focusing is a challenging problem and may cause unwanted hotspots on healthy tissues. Therefore, there is a need to monitor the temperature to ensure that tumor and healthy tissues are at desired temperatures. In this paper, an iterative differential microwave imaging algorithm for temperature monitoring is presented. The algorithm is based on Born iterative method (BIM) and Tikhonov regularization. Feasibility of the algorithm is shown computationally using realistic digital breast phantoms via (i) TMz polarized 2-D scattered fields; and (ii) scattered fields calibrated from scattering parameters, which are obtained by a 3-D electromagnetic simulation program. An approach for selection of matching medium in hyperthermia monitoring applications is also presented. The reconstructions are performed with scattered field data collected at 11 discrete frequency points uniformly taken from the 0.5-1.5 GHz range. For a specific heating scenario, reconstruction error is lower than 0.3% with ±10% noise on reference dielectric property distribution and 35 dB signal to noise ratio (SNR). The results show that the proposed approach provides up to 3°C and 0.1°C resolution in temperature estimation with ±10\% noise on reference dielectric property distribution for 25 dB and 55 dB SNR values, respectively.