Semih Doğu

Dr. Semih Doğu

Electronics and Communication Engineering, Istanbul Technical University, Istanbul, İstanbul, Turkey (Türkiye)
orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 January 2020 in IET Microwaves, Antennas & Propagation
Verified
Journal Article
Open access
PDF file
Semih DoğuSemih Doğu
Semih Doğu
MAMehmet Nuri Akıncı
Mehmet Nuri Akıncı
MÇMehmet Çayören
Mehmet Çayören
IAİbRahim Akduman
İbRahim Akduman
We considered differential through‐the‐wall microwave imaging with different formulations of truncated singular value decomposition (TSVD) method with a non‐anechoic experiment. Previous studies employ TSVD with single transmitting/measuring antenna, while we show how to apply the TSVD in case of a moving linear transmitting/measuring antenna array. Particularly, an averaging scheme is employed for repeated measurements. Three TSVD approaches are tested: (i) TSVD on Contrast Source, (ii) TSVD on Contrast, (iii) multi frequency TSVD on Contrast. For (i), the dimension of inverted matrix is relatively low. After solving equations, a normalisation is proposed for eliminating noise. For (ii), the reconstructions get better compared to (i) since measured data for all excitations are inverted simultaneously. Nevertheless, (ii) requires more time than (i), since the inverted matrix gets larger. Finally, for (iii), to avoid additional calibration, we employ the solutions of (ii). Then, the contrasts are estimated for all frequencies and excitations simultaneously. Thus, the inverted matrix is largest for (iii), accuracy is best, computational time is longest. For testing proposed techniques, a metallic scatterer is deployed behind a wall. Results show trade‐off between accuracy and computational time for choosing the suitable inversion method. Moreover, norm type selection is assessed for each method.

17 June 2025 in International Journal of Aeronautical and Space Sciences
Verified
Journal Article
Open access
PDF file
Yusuf Salih GurbetYusuf Salih Gurbet
Yusuf Salih Gurbet
Semih DoğuSemih Doğu
Semih Doğu
Cube satellites (CubeSats) have become increasingly popular in recent years due to their cost-effectiveness and the rapid production capabilities enabled by commercial off-the-shelf components. This research comprehensively reviews 45 antenna designs for CubeSats operating in high-frequency bands, specifically the Ku, K, and Ka bands. Among the antennas reviewed are fourteen patch and patch array antennas, one slot antenna, two leaky wave antennas, three array antennas, seven reflector antennas, eight reflectarray antennas, three metasurface antennas, four cavity-backed antennas, one helical antenna, one lens antenna, and one horn antenna. These antennas are evaluated based on performance parameters such as gain, bandwidth, reflection coefficient, CubeSat size, and deployability to determine which designs suit the limited space available on CubeSats. Particular attention is given to the challenges in designing CubeSat antennas, including achieving high gain, broad bandwidth, multi-band capability, low profile, and circular polarization. This research aims to enhance our understanding by identifying high-frequency antenna designs that may benefit future CubeSat missions.

9 March 2020 in IEEE Geoscience and Remote Sensing Letters
Verified
Journal Article
Closed access
Semih DoğuSemih Doğu
Semih Doğu
MAMehmet Nuri Akinci
Mehmet Nuri Akinci
EGErsin Gose
Ersin Gose
In this letter, imaging of moving targets with qualitative microwave imaging methods (Q-MWMs) is addressed. The problematic side of Q-MWM is the requirement of background measurement. To eliminate this necessity, the total electric field measured at different time instants (say Etotn and Etotl are the total electric fields measured at the nth and lth time instants, respectively) is applied to Q-MWM. For these input data, the output of Q-MWM can be assumed to be the summation of the indicators at these time instants (i.e., Etotn-Etotl produces the differential indicator Inl=In+Il, where In and Il are the indicators at the nth and lth time instants, respectively). Using this information for all possible time pairs, an equation system is set for indicator values at different time instants. Solving this equation system, the indicator of Q-MWM for each measurement time is obtained, without taking any background measurement. The performance of the proposed algorithm is verified for the linear sampling method (LSM), which is an example of Q-MWM, with the 3-D and 2-D [both transverse magnetic (TM) and transverse electric (TE)] experimental measurements performed in a nonanechoic environment.

18 January 2023 in IEEE Access
Verified
Journal Article
Open access
Semih DoğuSemih Doğu
Semih Doğu
HOHulusi Onal
Hulusi Onal
Tuba Yilmaz YilmazTuba Yilmaz Yilmaz
Tuba Yilmaz Yilmaz
Ibrahim AkdumanIbrahim Akduman
Ibrahim Akduman
MAMehmet Nuri Akinci
Mehmet Nuri Akinci
Qualitative microwave imaging methods provide a fast and accurate reconstruction of the shapes of the targets from scattered electric field measurements. In this paper, a qualitative imaging method, the singular sources method (SSM), is analyzed for two-dimensional transverse magnetic electromagnetic (2D-TM EM) inverse scattering scenarios. The contribution of the paper can be briefly summarized as: (i) The SSM was previously proposed for the far-field scenario, here we extend the SSM in the near field - inhomogeneous background setup. While making the extension each step (which includes an integral equation) is explained by exploiting the linearity and reciprocity principles to give physical insights. (ii) The relation between the electrical parameters of the scatterers and the indicator of SSM is derived. (iii) To analyze the performance of SSM in real-world problems, the proposed method is tested for monitoring hyperthermia treatment problems with a realistic breast model. Obtained results show that the SSM can handle realistic breast phantoms for monitoring hyperthermia problems.

1 January 2016
Verified
Conference Paper
Closed access
IDİsmail Dilman
İsmail Dilman
UYUgur Yildirim
Ugur Yildirim
SCSema Cosgun
Sema Cosgun
Semih DoğuSemih Doğu
Semih Doğu
MCMehmet Cayoren
Mehmet Cayoren
Ibrahim AkdumanIbrahim Akduman
Ibrahim Akduman
This paper investigates feasibility of detection of blooded area in a realistic head phantom with microwave imaging. Realistic phantom is illuminated by 36 line sources and the scattering field data is calculated numerically with method of moments. Additive white Gaussian noise with 20 dB is added for more realistic scenario. Contrast Source Inversion method is used to reconstruct the blooded area. Simulations are done at different operating frequencies of 500 MHz, 800 MHz and 1000 MHz. Moreover, results either with electrically different background mediums or free space are discussed in this study. The numerical results show that it is possible to determine the square shape blooded area with size about 2.6cm × 2.6cm between the 800-1000Mhz frequency range in the dielectric matching medium.

4 February 2025 in Journal of Nondestructive Evaluation
Verified
Journal Article
Open access
PDF file
MPMuhammed Ismail Pence
Muhammed Ismail Pence
CACemanur Aydinalp
Cemanur Aydinalp
Semih DoğuSemih Doğu
Semih Doğu
MAMehmet Nuri Akinci
Mehmet Nuri Akinci
High and low salinity levels play a crucial role in the vitality of organisms and affect natural ecosystems, agricultural yields and human health. To mitigate the risks associated with high blood pressure and cardiovascular diseases, the World Health Organization (WHO) advocates reducing salt consumption among adults, suggesting an intake of no more than 5 g daily. In this study, a non-invasive microwave (MW) sensing approach, that is augmented by deep neural network (DNN) models is proposed to predict salinity levels. The MW detection measurement system, including a Horn antenna, has been developed to evaluate the salt content in bottled spring waters (BSWs). The system with DNN model provides a novel solution for real-time water quality monitoring. The input and output dataset for DNN model were generated using four different BSWs, each with a salt content ranging from 0 to 32 g and increased by 1 g. The developed DNN model, designed with six fully connected layers, uses reflection coefficients (RCs) as input dataset to predict salt content in grams accurately. The accuracy performance of the DNN model in various bandwidths was evaluated by dividing the 1–13 GHz range into 78 different bands and the lowest error rate was found to be in the 1–8 GHz bandwidth (2.18%). Furthermore, each BSW was measured five times, and the performance of the model was evaluated according to the number of measurements. In three or more measurements, the model demonstrated notable improvement(15.3%) in predicting salt content.