Jean-Eric Ducret

Jean-Eric Ducret

Auto-generated profile, based on publicly available information

Jean-Eric Ducret

Caen Normandy Grand Accelerateur National d'Ions Lourds

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 August 2015 in Review of Scientific Instruments
Verified
Journal Article
Closed access
CBC. Baccou
C. Baccou
VYV. Yahia
V. Yahia
SDS. Depierreux
S. Depierreux
CNC. Neuville
C. Neuville
CGC. Goyon
C. Goyon
CLC. Labaune
C. Labaune
Laser-accelerated ion beams can be used in many applications and, especially, to initiate nuclear reactions out of thermal equilibrium. We have experimentally studied aneutronic fusion reactions induced by protons accelerated by the Target Normal Sheath Acceleration mechanism, colliding with a boron target. Such experiments require a rigorous method to identify the reaction products (alpha particles) collected in detectors among a few other ion species such as protons or carbon ions, for example. CR-39 track detectors are widely used because they are mostly sensitive to ions and their efficiency is near 100%. We present a complete calibration of CR-39 track detector for protons, alpha particles, and carbon ions. We give measurements of their track diameters for energy ranging from hundreds of keV to a few MeV and for etching times between 1 and 8 h. We used these results to identify alpha particles in our experiments on proton-boron fusion reactions initiated by laser-accelerated protons. We show that their number clearly increases when the boron fuel is preformed in a plasma state.

27 January 2022 in Universe
Verified
Journal Article
Open access
PDF file
DMDavid Mascali
David Mascali
DSDomenico Santonocito
Domenico Santonocito
SAS. Amaducci
S. Amaducci
LALucio Andò
Lucio Andò
VAVincenzo Antonuccio-Delogu
Vincenzo Antonuccio-Delogu
Luca VincettiLuca Vincetti
Luca Vincetti
Theoretical predictions as well as experiments performed at storage rings have shown that the lifetimes of β-radionuclides can change significantly as a function of the ionization state. In this paper we describe an innovative approach, based on the use of a compact plasma trap to emulate selected stellar-like conditions. It has been proposed within the PANDORA project (Plasmas for Astrophysics, Nuclear Decay Observation and Radiation for Archaeometry) with the aim to measure, for the first time in plasma, nuclear β-decay rates of radionuclides involved in nuclear-astrophysics processes. To achieve this task, a compact magnetic plasma trap has been designed to reach the needed plasma densities, temperatures, and charge-states distributions. A multi-diagnostic setup will monitor, on-line, the plasma parameters, which will be correlated with the decay rate of the radionuclides. The latter will be measured through the detection of the γ-rays emitted by the excited daughter nuclei following the β-decay. An array of 14 HPGe detectors placed around the trap will be used to detect the emitted γ-rays. For the first experimental campaign three isotopes, 176Lu, 134Cs, and 94Nb, were selected as possible physics cases. The newly designed plasma trap will also represent a tool of choice to measure the plasma opacities in a broad spectrum of plasma conditions, experimentally poorly known but that have a great impact on the energy transport and spectroscopic observations of many astrophysical objects. Status and perspectives of the project will be highlighted in the paper.

1 November 2017 in Review of Scientific Instruments
Verified
Journal Article
Closed access
PDF file
NRN. Rabhi
N. Rabhi
DBDimitri Dino Batani
Dimitri Dino Batani
GBG. Boutoux
G. Boutoux
JDJ.-E. Ducret
J.-E. Ducret
KJK. Jakubowska
K. Jakubowska
BVB. Vauzour
B. Vauzour
Responses of Fuji Imaging Plates (IPs) to proton have been measured in the range 1-200 MeV. Mono-energetic protons were produced with the 15 MV ALTO-Tandem accelerator of the Institute of Nuclear Physics (Orsay, France) and, at higher energies, with the 200-MeV isochronous cyclotron of the Institut Curie—Centre de Protonthérapie d’Orsay (Orsay, France). The experimental setups are described and the measured photo-stimulated luminescence responses for MS, SR, and TR IPs are presented and compared to existing data. For the interpretation of the results, a sensitivity model based on the Monte Carlo GEANT4 code has been developed. It enables the calculation of the response functions in a large energy range, from 0.1 to 200 MeV. Finally, we show that our model reproduces accurately the response of more complex detectors, i.e., stack of high-Z filters and IPs, which could be of great interest for diagnostics of Petawatt laser accelerated particles.

1 May 2018 in Physics of Plasmas
Verified
Journal Article
Closed access
PDF file
DBDimitri Dino Batani
Dimitri Dino Batani
GBG. Boutoux
G. Boutoux
FBF. Burgy
F. Burgy
KJK. Jakubowska
K. Jakubowska
JDJ. E. Ducret
J. E. Ducret
We present experimental results obtained at the CELIA laboratory using the laser ECLIPSE to study proton acceleration from ultra-intense laser pulses. Several types of targets were irradiated with different laser conditions (focusing and prepulse level). Proton emission was characterized using time-of-flight detectors (SiC and diamond) and a Thomson parabola spectrometer. In all cases, the maximum energy of observed protons was of the order of 260 keV with a large energy spectrum. Such characteristics are typical of protons emitted following the target normal sheath acceleration mechanism for low-energy short-pulse lasers like ECLIPSE.

1 April 2016 in Physics of Plasmas
Verified
Journal Article
Closed access
LTLorenzo Torrisi
Lorenzo Torrisi
MCM. Cutroneo
M. Cutroneo
GCGiovanni Ceccio
Giovanni Ceccio
ACA. Cannavò
A. Cannavò
DBDimitri Dino Batani
Dimitri Dino Batani
JDJ. E. Ducret
J. E. Ducret
A 200 mJ laser pulse energy, 39 fs-pulse duration, 10 μm focal spot, p-polarized radiation has been employed to irradiate thin Au foils to produce proton acceleration in the forward direction. Gold foils were employed to produce high density relativistic electrons emission in the forward direction to generate a high electric field driving the ion acceleration. Measurements were performed by changing the focal position in respect of the target surface. Proton acceleration was monitored using fast SiC detectors in time-of-flight configuration. A high proton energy, up to about 20 Me V, with a narrow energy distribution, was obtained in particular conditions depending on the laser parameters, the irradiation conditions, and a target optimization.

1 October 2016 in Review of Scientific Instruments
Verified
Journal Article
Closed access
GCG. Claps
G. Claps
DPD. Pacella
D. Pacella
FMF. Murtas
F. Murtas
KJK. Jakubowska
K. Jakubowska
GBG. Boutoux
G. Boutoux
DBDimitri Dino Batani
Dimitri Dino Batani
Laser produced plasmas lend to several interesting applications. The study of X-ray emission from this kind of plasmas is important not only to characterize plasmas itself but also to study the application of these particular plasmas as intense X-ray sources. In particular several emission configurations can be obtained using different kinds of targets and tuning the characteristics of the laser pulse delivered to the target. Typically, laser pulse duration ranges between a few tens of femtoseconds and tens of nanoseconds, with energies from few mJ to tens of kJ. X-ray photon emissions last for times comparable to the laser pulses and during this time a great number of photons can be emitted. The following paper presents a measure of the soft-X-ray emission on the ECLIPSE laser facility realized with a new triple-GEM gas detector (GEMpix). It is a hybrid gas detector with a C-MOS front-end electronics based on Medipix chips. In the present work, different targets have been used in order to test X-rays of different energies. In this paper, in particular, we present results obtained for copper and iron targets. GEMpix is able to realize a 2D imaging of the X-ray emission from plasma with a signal proportional to the energy released in the gas of the detector active volume. Then through a preliminary single photon equalization realized at the NIXT lab (ENEA), also the number of photons reaching the area of the detector has been estimated.