This article presents the development of a general MHz synchronous rectifier (SR) designed for resonant converters. It examines the potential losses in a nonideal SR, encompassing driving losses, conduction losses, switching losses, and body-diode losses. When employing the drain–source voltage for synchronization, it investigates the signal delay and mismatch introduced by detector, driver, and transistor parasitic to elucidate the challenges faced by a digital controller. To address these issues, this article proposes a fast synchronous phase control coupled with a slow adaptive dead-time control to dynamically modulate the driving signal. Experimentally, it implemented and tested a 60-W, 6.78-MHz rectifier in a wireless charger. The SR achieved a peak efficiency of 97.7%, ensuring at least a 5.0% efficiency improvement compared to a passive rectifier.
11 February 2025 in IEEE Transactions on Circuits and Systems I: Regular Papers
As an energy storage technology, supercapacitors feature a high power density. In particular, supercapacitors can be charged or discharged by a relatively large pulse current for a limited period of time. This paper takes advantage of this characteristic and develops a dual-mode fast charger for supercapacitors that employs both continuous and fine-tuned pulse currents. Based on the conventional forward converter, the proposed charger introduces an energy storage capacitor and a branch resistor to tune the rising and falling edges of the pulse current, respectively. Consequently, the transitions between the continuous and pulse current modes are significantly accelerated, which ultimately shortens the supercapacitor charging time. A prototype is built and tested using a 3 V/6 F supercapacitor. To charge the supercapacitor from 2 to 2.5 V, the proposed charger takes 0.87 and 1 s when it is configured to operate in the dual-mode and the continuous current mode only, respectively, which leads to a 13% reduction in the charging time. Moreover, compared to the forward converter, the pulse characteristics of the proposed charger are significantly improved in that the pulse rising and falling times are dramatically reduced: 2.1 versus 147 μs and 7.2 versus 103 μs, respectively.
27 June 2024 in IEEE Transactions on Industrial Electronics
This article focuses on stability analysis and control in a two-stage inductive power transfer (IPT) system. It aims to derive an accurate output impedance model for the unregulated IPT stage, investigating its impact on the downstream buck converter. Practical considerations for bus capacitance and controller type are discussed to balance stability, filter size, and bandwidth, emphasizing the practical importance of impedance analysis for stable multistage IPT setups. A practical 200-kHz system is constructed to verify the stability analysis. The use of an analytical model, grounded in clear physical interpretations, assists in guiding the linear control of the buck converter at a high crossover frequency 28 kHz. Alternatively, it aids in selecting a conservative control approach to reduce the bus capacitance.