Marco Piola

Marco Piola

Auto-generated profile, based on publicly available information

Marco Piola

Dipartimento di Elettronica, Informazione e Bioingegneria, Politecnico di Milano, P.zza Leonardo da Vinci 32, 20133, Milan, Italy.

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 February 2015 in PLOS ONE
Verified
Journal Article
Open access
PDF file
FPFrancesca Prandi
Francesca Prandi
MPMarco Piola
Marco Piola
Monica SonciniMonica Soncini
Monica Soncini
CCClaudia. Colussi
Claudia. Colussi
YDYuri D'Alessandra
Yuri D'Alessandra
Maurizio PesceMaurizio Pesce
Maurizio Pesce
Saphenous vein graft disease is a timely problem in coronary artery bypass grafting. Indeed, after exposure of the vein to arterial blood flow, a progressive modification in the wall begins, due to proliferation of smooth muscle cells in the intima. As a consequence, the graft progressively occludes and this leads to recurrent ischemia. In the present study we employed a novel ex vivo culture system to assess the biological effects of arterial-like pressure on the human saphenous vein structure and physiology, and to compare the results to those achieved in the presence of a constant low pressure and flow mimicking the physiologic vein perfusion. While under both conditions we found an activation of Matrix Metallo-Proteases 2/9 and of microRNAs-21/146a/221, a specific effect of the arterial-like pressure was observed. This consisted in a marked geometrical remodeling, in the suppression of Tissue Inhibitor of Metallo-Protease-1, in the enhanced expression of TGF-β1 and BMP-2 mRNAs and, finally, in the upregulation of microRNAs-138/200b/200c. In addition, the veins exposed to arterial-like pressure showed an increase in the density of the adventitial vasa vasorum and of cells co-expressing NG2, CD44 and SM22α markers in the adventitia. Cells with nuclear expression of Sox-10, a transcription factor characterizing multipotent vascular stem cells, were finally found in adventitial vessels. Our findings suggest, for the first time, a role of arterial-like wall strain in the activation of pro-pathologic pathways resulting in adventitial vessels growth, activation of vasa vasorum cells, and upregulation of specific gene products associated to vascular remodeling and inflammation.

17 October 2016 in Annals of Biomedical Engineering
Verified
Journal Article
Closed access
PDF file
MPMarco Piola
Marco Piola
MRMatthijs Ruiter
Matthijs Ruiter
RVRiccardo Vismara
Riccardo Vismara
VMValeria Mastrullo
Valeria Mastrullo
MAMarco Agrifoglio
Marco Agrifoglio
GFGianfranco Beniamino Fiore
Gianfranco Beniamino Fiore

30 July 2013 in Journal of Tissue Engineering and Regenerative Medicine
Verified
Journal Article
Closed access
PDF file
MPMarco Piola
Marco Piola
FPFrancesca Prandi
Francesca Prandi
NINA BONONINA BONO
NINA BONO
Monica SonciniMonica Soncini
Monica Soncini
EPEleonora Penza
Eleonora Penza
GFGianfranco Beniamino Fiore
Gianfranco Beniamino Fiore
Saphenous vein (SV) graft disease represents an unresolved problem in coronary artery bypass grafting (CABG). After CABG, a progressive remodelling of the SV wall occurs, possibly leading to occlusion of the lumen, a process termed 'intima hyperplasia' (IH). The investigation of cellular and molecular aspects of IH progression is a primary end-point toward the generation of occlusion-free vessels that may be used as ‘life-long’ grafts. While animal transplantation models have clarified some of the remodelling factors, the pathology of human SV is far from being understood. This is also due to the lack of devices able to reproduce the altered mechanical load encountered by the SV after CABG. This article describes the design of a novel ex vivo vein culture system (EVCS) capable of replicating the altered pressure pattern experienced by SV after CABG, and reports the results of a preliminary biomechanical conditioning experimental campaign on SV segments. The EVCS applied a CAGB-like pressure (80–120 mmHg) or a venous-like perfusion (3 ml/min, 5 mmHg) conditioning to the SVs, keeping the segments viable in a sterile environment during 7 day culture experiments. After CABG-like pressure conditioning, SVs exhibited a decay of the wall thickness, an enlargement of the luminal perimeter, a rearrangement of the muscle fibres and partial denudation of the endothelium. Considering these preliminary results, the EVCS is a suitable system to study the mechanical attributes of SV graft disease, and its use, combined with a well-designed biological protocol, may be of help in elucidating the cellular and molecular mechanisms involved in SV graft disease. Copyright © 2013 John Wiley & Sons, Ltd.

19 February 2016 in Medical Engineering & Physics
Verified
Journal Article
Closed access
RVRiccardo Vismara
Riccardo Vismara
ALAlberto M. Leopaldi
Alberto M. Leopaldi
MPMarco Piola
Marco Piola
CAChiara Asselta
Chiara Asselta
MLMassimo Lemma
Massimo Lemma
GFGianfranco B. Fiore
Gianfranco B. Fiore
Recent approaches to the in vitro experimental study of cardiac fluid mechanics involve the use of whole biological structures to investigate in the lab novel therapeutic approaches for the treatment of heart pathologies. To enhance reliability and repeatability, the influence of the actuation strategy of the experimental apparatuses on the biomechanics of biological structures needs to be assessed. Using echography and intracardiac high-speed imaging, we compared the mitral valve (MV) anatomo-functional features (coaptation areas/lengths, papillary muscles-valvular plane distances) in two passive-beating-heart mock loops with internal (IPML) or external (EPML) pressurization of the ventricular chamber. Both apparatuses showed fluid dynamic conditions that closely resembled the physiology. The MVs analyzed in the EPML presented coaptation areas and lengths that were systematically higher, and exhibited greater variability from early-to peak-systole, as compared to those in the IPML. Moreover, in the EPML, the MV leaflets exhibited a convexity with high curvature toward the atrium. With the IPML, MV coaptation lengths ranged similar to available clinical data and the papillary muscles-valve plane distances were more stable throughout systole. In conclusion, both the apparatuses allow for reproducing in vitro the left heart hemodynamics, in terms of flow rates and pressures, with proper mitral valve continence. Results suggest that the IPML is more suitable for replicating the physiological MV functioning, while the EPML may have more potential as a model for the study of MV pathologies.

1 January 2013 in The Scientific World Journal
Verified
Journal Article
Open access
PDF file
MPMarco Piola
Marco Piola
Monica SonciniMonica Soncini
Monica Soncini
MCMarco Cantini
Marco Cantini
NSNasser Sadr
Nasser Sadr
GFGiulio Ferrario
Giulio Ferrario
GFGianfranco B Fiore
Gianfranco B Fiore
Perfusion culture systems are widely used in tissue engineering applications for enhancing cell culture viability in the core of three‐dimensional scaffolds. In this work, we present a multichamber confined‐flow perfusion system, designed to provide a straightforward platform for three‐dimensional dynamic cell cultures. The device comprises 6 culture chambers allowing independent and simultaneous experiments in controlled conditions. Each chamber consists of three parts: a housing, a deformable scaffold‐holder cartridge, and a 7 mL reservoir, which couples water‐tightly with the housing compressing the cartridge. Short‐term dynamic cell seeding experiments were carried out with MC3T3‐E1 cells seeded into polycaprolactone porous scaffolds. Preliminary results revealed that the application of flow perfusion through the scaffold favored the penetration of the cells to its interior, producing a more homogeneous distribution of cells with respect to dropwise or injection seeding methods. The culture chamber layout was conceived with the aim of simplifying the user operations under laminar flow hood and minimizing the risks for contamination during handling and operation. Furthermore, a compact size, a small number of components, and the use of bayonet couplings ensured a simple, fast, and sterility‐promoting assembling. Finally, preliminary in vitro tests proved the efficacy of the system in enhancing cell seeding efficiency, opening the way for further studies addressing long‐term scaffold colonization.

23 March 2015 in Journal of Biomedical Materials Research Part B: Applied Biomaterials
Verified
Journal Article
Closed access
PDF file
Rosaria SantoroRosaria Santoro
Rosaria Santoro
FCFilippo Consolo
Filippo Consolo
MSMarco Spiccia
Marco Spiccia
MPMarco Piola
Marco Piola
SKSamer Kassem
Samer Kassem
Maurizio PesceMaurizio Pesce
Maurizio Pesce