Minrui Gu

Minrui Gu

Auto-generated profile, based on publicly available information

Minrui Gu

School of Electrical Engineering, Southeast University, Nanjing, China

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 March 2020 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
XWXueqing Wang
Xueqing Wang
ZWZheng Wang
Zheng Wang
MGMinrui Gu
Minrui Gu
DXDianxun Xiao
Dianxun Xiao
JiangBiao HeJiangBiao He
JiangBiao He
AEAli Emadi
Ali Emadi
Aiming at tolerating common electric faults of multiphase motor drives comprehensively and minimizing the adverse impacts from the remedial scheme itself, a diagnosis-free self-healing scheme is put forward for the open-circuit faults of dual three-phase permanent-magnet synchronous motor (PMSM) drives. Firstly, the self-healing mechanisms of dual three-phase PMSM drives are analyzed in detail. On the basis of theoretical analysis, the repressed self-healing capability of the dual three-phase PMSM drives is fully released by optimizing the current references on harmonic subspace. Since the diagnosis process is not required in the proposed self-healing scheme, the misdiagnosis problem and the prolonged damage caused by the additional time cost of diagnosis can be fundamentally avoided. The proposed self-healing scheme can be generally applied to open-switch faults, single open-phase faults and multiple open-phase faults in the multiphase motor drives. No change is required for the machine model, modulation strategy or control framework under different open-circuit faults. Thus, the complex transition strategies among different fault-tolerant control methods for different faults can be avoided, and the adverse impacts from the remedial scheme itself can be minimized. Experimental verification is presented to prove the validity of the proposed self-healing scheme.

26 March 2021 in IEEE Transactions on Power Electronics
Verified
Journal Article
Open access
MGMinrui Gu
Minrui Gu
ZWZheng Wang
Zheng Wang
KYKailiang Yu
Kailiang Yu
XWXueqing Wang
Xueqing Wang
Ming ChengMing Cheng
Ming Cheng
In this article, the control strategy is studied for the neutral-point-clamped three-level inverter-fed dual three-phase permanent-magnet synchronous motor (PMSM) drive with low switching frequencies. An interleaved finite-control-set model predictive control (MPC) scheme is proposed, where a two-layer MPC is designed to solve the multiobjective optimization problem. The two sets of windings in PMSM are sampled and controlled in an interleaved way so that the control delay and the prediction horizon of the drive system are reduced by half. Moreover, the proposed interleaved control scheme increases the equivalent sampling and control frequency from the perspective of the whole drive system, and thus provides better steady-state performance and dynamic performance. With the switching states of one inverter remaining unchanged, the cross traversal of vector candidate sets between two sets of windings is avoided, and the computational burden can be reduced effectively. Experimental results are given to verify the validity and effectiveness of the proposed interleaved control scheme.

21 November 2022 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
ZWZheng Wang
Zheng Wang
KYKailiang Yu
Kailiang Yu
YLYuqing Li
Yuqing Li
MGMinrui Gu
Minrui Gu
Dual three-phase interior permanent-magnet synchronous motor (IPMSM) drives have received more attention by the merits of better fault-tolerant capability and lower torque ripples. To improve the reliability of the system against failures in position sensor, it is necessary to investigate the position estimation method for dual three-phase IPMSM drives. The high-frequency (HF) signals injection is utilized for position estimation in three-phase IPMSM drives during low-speed operation region. However, the torque ripples are inevitable owing to the mixing of fundamental and HF components in the same control space for three-phase IPMSM drives. In this article, the position sensorless control method has been proposed by injecting HF square-wave voltage in the harmonic subspace for the dual three-phase IPMSM drives. Since the harmonic subspace is decoupled from the torque subspace, the torque disturbance can be mitigated well with the proposed HF signal injection-based position sensorless method. Moreover, the digital filters in signal extraction and current feedback can be avoided and the signal separation process becomes easy with the proposed method. The experiments have been conducted to validate the performance of the proposed method.

25 September 2020 in IEEE Transactions on Industry Applications
Verified
Journal Article
Closed access
XWXueqing Wang
Xueqing Wang
ZWZheng Wang
Zheng Wang
MGMinrui Gu
Minrui Gu
ZXZhixian Xu
Zhixian Xu
Zhixiang ZouZhixiang Zou
Zhixiang Zou
Ming ChengMing Cheng
Ming Cheng
In this paper, a deadbeat predictive current control based fault-tolerant control scheme is proposed for common electrical faults in T-type three-level inverter fed dual three-phase PMSM drives, which aims at providing a solution for the application of high power rating, low switching frequency, low complexity and high reliability. Firstly, deadbeat control is combined with current prediction to obtain precise voltage reference for the current control. Each three-phase three-level inverter generates a single optimal inverter voltage vector based on a new division method of space vector diagram. In this way, both low switch frequency and high control precision can be guaranteed in a high-power motor system. Secondly, fault-tolerant control schemes are designed for five types of common electric faults in T-type three-level inverter fed dual three-phase PMSM without changing the mathematical model and control framework. Thus, the complexity of the proposed fault-tolerant control schemes can be avoided and smooth transition can be guaranteed. The validity of the proposed schemes is verified by experimental results.

6 November 2020 in IEEE Transactions on Energy Conversion
Verified
Journal Article
Closed access
XWXueqing Wang
Xueqing Wang
ZWZheng Wang
Zheng Wang
MGMinrui Gu
Minrui Gu
Bo WangBo Wang
Bo Wang
Wei WangWei Wang
Wei Wang
Ming ChengMing Cheng
Ming Cheng
A standard three-phase motor drive means a typical two-level voltage source inverter fed three-phase motor drive without any auxiliary circuits. Without fault-tolerant control, common open-circuit faults will cause the breakdown of the standard three-phase motor drives. Although the torque pulsation is theoretically inevitable under the open-circuit faults of standard three-phase motor drives, it's still meaningful to improve the fault-tolerant capability of standard three-phase drives to prolong the reliable operation. In this paper, a current optimization based fault-tolerant control is proposed to minimize the proportion of torque loss for standard three-phase permanent-magnet synchronous motor (PMSM) drives under open-phase fault and open-switch fault conditions. Firstly, a two-mode current control is designed to minimize the proportion of torque loss without changing the mathematical model of the faulty motor. Secondly, a three-mode current control is proposed and combined with adjustment of pulse width to tolerate the open-switch faults. Instead of removing the faulty inverter leg directly, the remaining healthy switch in the faulty inverter leg is still utilized. In this way, the damage from torque pulsation can be relieved in the aspect of both frequency and intensity. Finally, the validity of the proposed fault-tolerant control is verified by experiments.

17 April 2023 in IEEE Transactions on Transportation Electrification
Verified
Journal Article
Closed access
MGMinrui Gu
Minrui Gu
ZWZheng Wang
Zheng Wang
Pengcheng LiuPengcheng Liu
Pengcheng Liu
JiangBiao HeJiangBiao He
JiangBiao He
In this paper, multiple advanced low-switching-frequency modulation and control schemes are investigated for dual three-phase permanent-magnet synchronous motor (PMSM) drives. The modulation schemes under investigation include multisampling space vector modulation (MS-SVM), selective harmonic elimination pulse width modulation (SHEPWM) and synchronous optimal pulse width modulation (SOPWM) while the control schemes include complex vector control, model predictive control (MPC) and flux trajectory control-based model predictive pulse pattern control (MP 3 C). The difference between three-phase and dual three-phase PMSM drives at low switching frequencies is analyzed. Moreover, an optimal pulse width modulation (PWM)-based MP 3 C scheme is proposed for the dual three-phase PMSM, where the optimal PWM modulation and MP 3 C control are combined such that the optimal steady-state and dynamic control performance is achieved among the modulation and control schemes investigated. Experimental results are given to compare and validate the proposed control scheme.