29 December 2016 in IEEE Electron Device Letters
This letter reports on a tin oxide (SnO) thin-film transistor (TFT) with p-type conduction that uses aluminum (Al) doping in the SnO active channel layer. Performance enhancements were further achieved by applying fluorine plasma treatment on the p-type Al-doped SnO channel layer. The effects of the fluorine plasma treatment were also investigated.By tuning the power of the fluorine plasma treatment on the p-type Al-doped SnO channel layer, the optimal TFT device showed a very high on/off current ratio of 2.58×106 and a low threshold swing of 174 mV/decade, which could be attributed to the passivation effect of the plasma fluorination on the dominant donor-like traps at the SnO/HfO2 interface, as reflected by the suppression of the hysteresis phenomenon, the low density of interface traps, and the small subthreshold swing. The results indicate that the p-type Al-doped SnO TFT device with fluorine plasma treatment has considerable potential for application in future high-performance displays.
18 March 2021 in ACS Nano
27 January 2023 in IEEE Transactions on Electron Devices
The quality, resolution, and quantity of information transmitted in RF front end modules favor compact tunable filters with varactor elements that can handle high power and that are highly linear. Gallium nitride (GaN) varactors can theoretically reach the highest quality factor figure of merit (QFOM), owing to the GaN outstanding breakdown electric field and good electron mobility. Popularly pursued GaN Schottky diode varactors suffer from leakage currents at high reverse voltage biases at their junctions and because of GaN inherent threading dislocations in thin GaN layers on foreign substrates. We devised a novel device architecture to overcome these limitations. First, we employ an interdigitated anti-series multi-Fin camel diode structure composed of a thin $\text{p}^{+}$ GaN top layer situated between the Schottky metal and an n-type GaN drift layer. The anti-series symmetric Fin structure leads to excellent linearity and minimizes device parasitics to achieve measured record high ${Q}$ factors. The p-GaN layer raises the barrier height to suppress reverse leakage current to maintain a high ${Q}$ factor at higher reverse biases than Schottky diodes. Second, we utilize GaN on Qromis Substrate Technology (QST) wafers that permit the growth of thick GaN layers with lower dislocation densities and lower leakage currents than GaN-on-Si and that are comparable to GaN-on-GaN. We report in this work the fabrication and dc, RF ${S}$ -parameters of these diodes, and assess their potential with empirical models. Breakdown voltage of 146 V and extrapolated ${Q}$ factor of 84, 33, and 9 at 2, 5, and 18 GHz, respectively, are obtained in multi-Fin back-to-back varactor device configuration.
24 April 2024 in Science Translational Medicine
Functional mapping during brain surgery is applied to define brain areas that control critical functions and cannot be removed. Currently, these procedures rely on verbal interactions between the neurosurgeon and electrophysiologist, which can be time-consuming. In addition, the electrode grids that are used to measure brain activity and to identify the boundaries of pathological versus functional brain regions have low resolution and limited conformity to the brain surface. Here, we present the development of an intracranial electroencephalogram (iEEG)–microdisplay that consists of freestanding arrays of 2048 GaN light-emitting diodes laminated on the back of micro-electrocorticography electrode grids. With a series of proof-of-concept experiments in rats and pigs, we demonstrate that these iEEG-microdisplays allowed us to perform real-time iEEG recordings and display cortical activities by spatially corresponding light patterns on the surface of the brain in the surgical field. Furthermore, iEEG-microdisplays allowed us to identify and display cortical landmarks and pathological activities from rat and pig models. Using a dual-color iEEG-microdisplay, we demonstrated coregistration of the functional cortical boundaries with one color and displayed the evolution of electrical potentials associated with epileptiform activity with another color. The iEEG-microdisplay holds promise to facilitate monitoring of pathological brain activity in clinical settings.