6 January 2023 in IEEE Sensors Journal
In this paper, an ultra-sensitive temperature sensor based on enhanced vernier effect is presented. It consists of a double-groove cavity (DGC) and an open cavity (OC) filled with polydimethylsiloxane (PDMS). The length of DGC is limited by two single-mode fibers (SMF), and the length of OC is not limited. The two sensing cavities are affected by the thermal optic effect (TOE) and thermal expansion effect (TEE). Their interference dip of the spectra shifts to the opposite directions respectively, which realizes the enhanced vernier effect. The sensitivity of the sensor can be further improved, and the interference caused by the reference cavity can be also eliminated. The experimental results show that the sensor exhibits a high temperature sensitivity of 11.93 nm/°C. Compared to the traditional sensors based on vernier effect using TOE (3.33 nm/°C) or TEE (8.62 nm/°C) alone, the sensitivity increased by 264.8 % and 38.4 % respectively. As such, we believe that the proposed sensor has great application potential in biochemical detection, aeronautical engineering and environmental monitoring.
12 April 2022 in IEEE Sensors Journal
In this paper, we propose a curvature and temperature sensor based on two symmetrical grooves and a hollow core fiber (HCF) filled with polydimethylsiloxane (PDMS). The two grooves are produced by splicing both ends of the polished HCF with two multimode fibers (MMFs). The proposed groove structure is sensitive to curvature, and the PDMS, with a high thermo-optical coefficient, makes the sensor highly sensitive to temperature. The experimental results show that the sensor exhibits a high sensitivity of −6.833 nm/m −1 in the curvature range of 0 m −1 to 45.97m −1 , and a high sensitivity of 4.278 nm/°C in the temperature range of 25°C to 95°C. The proposed sensor can monitor curvature and temperature simultaneously in real-time, and has potential application prospects in industrial production, biomedicine, structural health monitoring, and other fields.
19 November 2020 in Journal of Lightwave Technology
Orbital angular momentum (OAM) of light provides a new dimension to increase the communication capacity. The compact and miniaturized devices are preferred because of the advantages in reliability and easy integration. In this work, a quarter-ring-shaped phase-gradient metasurface (QR-PGM) is proposed to sort various propagating waves into fully separated waveguide channels according to their OAM states. The principle is based on focal spot shifting arising from the constructive interference of surface plasmon polaritons with azimuthal phase modulated by the vortex beam. A thorough analysis of the SPP focusing properties was also carried out, which suggests the superiority of quarter-circular arc in OAM sorting (compared with half-circular arc). Focusing efficiency of the QR-PGM reaches to 25%, owing to dense sampling of incident light and unidirectional excitation of SPPs. By coupling spots to waveguides, the wide band on-chip sorting was demonstrated. In the broad wavelength band from 1.3 to 1.6 μm, the extinction ratio of each waveguide port keeps above 3 dB. The proposed structure is compact, efficient, wavelength-division-multiplexing-compatible, and easy to integrate with other on-chip devices. It will be a promising element for high capacity optical communication systems.
18 December 2024 in Journal of Lightwave Technology
The widespread utilization of microfluidics has increased the demand for flow rate precisely sensing in channel. In this paper, we propose a fiber-tip laminar flow rate sensor with temperature compensated based on three-beam interferometer, which is composed by a piece of polydimethylsiloxane (PDMS) and air in a section of hollow core fiber (HCF) sealed by graphene oxide (GO) film. Fluid with different flow rate will cause different impacts on the GO film, causing changes of the length of the air cavity. PDMS in the bottom of the cavity serves as a temperature-compensated portion because of the high thermo-optical coefficient (TOC) for testing the flow rate of microfluidics with different temperatures. The change of the length of the air cavity and the refractive index (RI) of the PDMS both will cause the shifting of the interference dips in the spectrum of the flow rate sensor. The ultra-thin GO film indicates that the sensor has a high-rate sensitivity, which can be used for the laminar flow rate measuring. The flow rate sensitivity can reach −44.679 nm/(mL/min) in the range of 0.01 to 0.1 mL/min. The actual flow field rate in the channel is obtained because the influence of the probe sensor embedding on the flow rate field is compensated during the calibration process. In addition, the sensor demonstrates a high-temperature compensated sensitivity of 30.963 nm/°C. This work provides a compact all-optical solution for laminar flow rate monitoring, which can also be applied to flow rate measuring in drug delivery, blood osmometry and bioanalysis.