To enhance humidity sensitivity, a parallel Fabry–Perot interferometer (FPI)-based Vernier scheme is theoretically and experimentally developed via the parallel and separated micro-cavities of polyvinyl alcohol (PVA) and hollow core fiber (HCF). Through Au-film assistance and fine attenuation adjustment, the matched light energy of micro-cavities is obtained and high-contrast envelope with ~11-fold improvement is demonstrated within the 200-nm range. Centering the $\sim 77~\mu \text{m}$ length Au-PVA micro-cavity, the comprehensive tests in terms of humidity are conducted. The experimental results show that, owing to the magnification of Vernier effect, ultra-sensitive humidity response of −9.14 nm/%RH is gained. And the crosstalk of temperature is constrained within −0.0843%RH/°C. In addition, 0.505 s dynamic time-response is verified through field tests of breathing. With the merits of stability, compact size, and ease of operation, our scheme is very practical and has potential in the applications of humidity-related biochemical sensing and medical health monitoring.
An ultra-simple microchannel-free fiber-optic gas-pressure sensor based on a section of quartz capillary is proposed. The resonance peaks and interference fringes can be both shown in the reflection spectrum and they are both sensitive to the variation of the gas refractive index and temperature. The gas-pressure can be demodulated by using sensing matrix. As the quartz capillary is open completely at its end, the pressure response time is reduced to 0.02s for the pressure variation of 0.1MPa. The proposed sensor can have actual applications in 24-hour gas-pressure monitoring and early warning in harsh environment, because of its ultra-simple and all-silica structure, ultra-fast response, good repeatability, and ultra-low fabrication cost.
In this paper, we propose a curvature and temperature sensor based on two symmetrical grooves and a hollow core fiber (HCF) filled with polydimethylsiloxane (PDMS). The two grooves are produced by splicing both ends of the polished HCF with two multimode fibers (MMFs). The proposed groove structure is sensitive to curvature, and the PDMS, with a high thermo-optical coefficient, makes the sensor highly sensitive to temperature. The experimental results show that the sensor exhibits a high sensitivity of −6.833 nm/m −1 in the curvature range of 0 m −1 to 45.97m −1 , and a high sensitivity of 4.278 nm/°C in the temperature range of 25°C to 95°C. The proposed sensor can monitor curvature and temperature simultaneously in real-time, and has potential application prospects in industrial production, biomedicine, structural health monitoring, and other fields.
Monitoring the properties of fluids in microfluidic chips often requires complex open-space optics technology and expensive equipment. In this work, we introduce dual-parameter optical sensors with fiber tips into the microfluidic chip. Multiple sensors were distributed in each channel of the chip, which enabled the real-time monitoring of the concentration and temperature of the microfluidics. The temperature sensitivity and glucose concentration sensitivity could reach 314 pm/°C and −0.678 dB/(g/L), respectively. The hemispherical probe hardly affected the microfluidic flow field. The integrated technology combined the optical fiber sensor with the microfluidic chip and was low cost with high performance. Therefore, we believe that the proposed microfluidic chip integrated with the optical sensor is beneficial for drug discovery, pathological research and material science investigation. The integrated technology has great application potential for micro total analysis systems (μ-TAS).
6 December 2023 in Journal of Lightwave Technology
A novel torsion sensor based on modal interference and the Lyot filter by utilizing the exciting mode in the single eccentric hole-assisted dual-core fiber (SEHADCF). Based on the interaction between the polarization functional modes and the mode of the suspended core, the phenomena of the interference resonance enhancement and the enhanced Vernier are realized by only adjusting the polarization of the incident light. The sensitivity of the proposed sensor reaches 171.97 dB/rad and 58.87 nm/rad, respectively. Furthermore, the vector property of the polarization state makes it possible to identify both the direction and the degree of the twist applied on the structure. Due to the selective amplification only applied on the parameter of the vector, the crosstalk from other mechanical parameters, including curvature and strain, is decreased significantly. The crosstalk of the strain is low to 7.474 ×10 -7 rad/με. The proposed scheme of the sensor provides a new perspective of regulating both the polarization state and the fiber mode in the sensing field.
18 December 2024 in Journal of Lightwave Technology
The widespread utilization of microfluidics has increased the demand for flow rate precisely sensing in channel. In this paper, we propose a fiber-tip laminar flow rate sensor with temperature compensated based on three-beam interferometer, which is composed by a piece of polydimethylsiloxane (PDMS) and air in a section of hollow core fiber (HCF) sealed by graphene oxide (GO) film. Fluid with different flow rate will cause different impacts on the GO film, causing changes of the length of the air cavity. PDMS in the bottom of the cavity serves as a temperature-compensated portion because of the high thermo-optical coefficient (TOC) for testing the flow rate of microfluidics with different temperatures. The change of the length of the air cavity and the refractive index (RI) of the PDMS both will cause the shifting of the interference dips in the spectrum of the flow rate sensor. The ultra-thin GO film indicates that the sensor has a high-rate sensitivity, which can be used for the laminar flow rate measuring. The flow rate sensitivity can reach −44.679 nm/(mL/min) in the range of 0.01 to 0.1 mL/min. The actual flow field rate in the channel is obtained because the influence of the probe sensor embedding on the flow rate field is compensated during the calibration process. In addition, the sensor demonstrates a high-temperature compensated sensitivity of 30.963 nm/°C. This work provides a compact all-optical solution for laminar flow rate monitoring, which can also be applied to flow rate measuring in drug delivery, blood osmometry and bioanalysis.