5 July 2021 in IEEE Transactions on Nuclear Science
The dependence of temperature and back-gate bias on single-event upset (SEU) sensitivity is investigated based on a 0.2- $\mu \text{m}$ double silicon-on-insulator (DSOI) technology. At room temperature, an obvious decrease in SEU cross section with the negative back-gate bias is experimentally observed for a DSOI static random access memory (SRAM). The physical mechanism of single-event effect (SEE) is explained through technology computer-aided design (TCAD) simulations. TCAD simulations were also performed to explain the impact of back-gate bias on charge collection and full width at half maximum (FWHM) of the pulsewidth at various temperatures. Both charge collection and FWHM of the pulsewidth increase significantly with temperature rising from 240 to 400 K. It is demonstrated that the SEU threshold linear energy transfer (LET) for a DSOI 6T SRAM cell decreases with an increase in temperature. Compared with a fully depleted SOI (FDSOI) technology, the unique independent back-gate bias scheme for a DSOI SRAM cell exhibits higher tolerance to SEU. At 400 K, it is found that the SEU threshold LET (LET th ) for a DSOI 6T SRAM cell increases by 12.5% with back-gate bias of nMOS reduced from 0 to −15 V.
27 November 2024 in IEEE Transactions on Nuclear Science
The total ionizing dose (TID) response of double silicon-on-insulator (DSOI) devices are comprehensively compared with that of traditional silicon-on-insulator (SOI) devices. Through revisiting the threshold voltage degradation after TID irradiation, we experimentally demonstrate that the N-channel DSOI devices degrades more significantly than their SOI counterparts with the same fabrication technology. The constant voltage stress was first discussed, which almost shows no influence. With the assistance of low-frequency noise measurements, the differences in average trap densities within the front gate oxide can also be eliminated. Furthermore, the oxide charge densities were extracted for the first buried oxide (BOX1) in DSOI and the buried oxide in SOI, which are nearly identical. Both simulations and experiments demonstrate that the observed difference of threshold voltage degradation is directly attributed to radiation-induced defects generated in the second buried oxide layer (BOX2) of DSOI devices. These defects subsequently alter the distribution of defects in BOX1 following irradiation. This independent and dynamic adjustment of the back gate in DSOI transistors can facilitate the flexible design of TID-hardened circuits.
16 November 2023 in IEEE Transactions on Nuclear Science
This paper concerns the top silicon layer thickness (TSOI1) and back-gate bias dependence of single event upset (SEU) cross section in 0.18 μm DSOI Static Random Access Memory (SRAM) through high LET heavy ions experiments. The experimental results show that the SEU cross section increases as the LET rises. The thickness of the top silicon layer is a critical factor for SEU sensitivity in DSOI SRAM. The overall SEU cross section for the SRAM with T SOI1 = 65 nm was ~32X larger than that of the SRAM with T SOI1 = 45 nm due to the reduction in collected charge. It is experimentally demonstrated that back-gate bias applied during heavy ion exposure strongly impacts SEU sensitivity. The 6T SRAM circuit exhibits exceptionally high tolerance to SEU by adjusting the back-gate bias. A back-gate biasing strategy is proposed in DSOI SRAM circuits which significantly lowers SEU sensitivity and power without performance loss. The physical mechanism of the effect of back-gate bias on SEU is explained through technology computer-aided design (TCAD) simulations, where the charge collection in a single transistor and the static noise margin in a 6T SRAM cell are analyzed. 6T SRAM can mitigate SEU with LET value up to 118 MeV·cm 2 /mg. The proposed DSOI SRAM shows a highly reliable and low-power capability which is preferred in extreme radiation environment applications.
5 June 2025 in IEEE Transactions on Electron Devices
In this article, the impact of temperature on non-equilibrium body potential (NEBP) is studied in silicon-on-insulator Schottky-barrier field effect transistors (SOI SBFETs). Both experiments and simulations show that the rising rate and peak value of NEBP go down with temperature increase, which leads to an earlier falling edge. This phenomenon can be attributed to the increase of the Schottky diode current, resulting in the supplement of electrons in the top silicon layer and an earlier falling of NEBP is present. A modified analytical model of NEBP is adapted based on majority carrier redundancy, which is validated by technology computer aided design (TCAD) simulations.
27 February 2025 in IEEE Transactions on Instrumentation and Measurement
A new transient method has been adapted to detect the radiation dose of γ-ray based on pseudo-MOSFETs. In addition, the electrical stress annealing effect is studied after irradiation experiments without biasing. In order to reduce the impact of annealing effect on the dose detection results, the transient non-equilibrium body potential was measured to extract the threshold and flat-band voltages using a new mathematical method. Based on these two voltages, the charge separate method is employed to determine the midband voltage. A lookup table and functional relationship are obtained with respect to the shift of the midband voltage and the total dose. This mathematical method is verified through both simulations and experiments, which show similar dose detection range to commercial dosimeter. Compared with the conventional quasi-static method, the transient data processing method using non-equilibrium body potential exhibits well accuracy and weak electrical stress annealing effect, which brings great benefits for radiation dose metrology.
2 March 2026 in IEEE Transactions on Nuclear Science
The synergistic effects of the total ionizing dose (TID) and single-event upset (SEU) are investigated in a 0.18-μm double silicon-on-insulator (DSOI) static random access memory (SRAM), and the impacts of top silicon-layer thickness (TSOI1) and back-gate bias are discussed. Experimental results show that the TID irradiation significantly enhances the SEU cross-section; specifically, at LET = 86.1 MeV·cm²/mg, a TID of 1000 krad(Si) increases the SEU cross-section by a factor of 2.7. Thanks to reduced charge collection, a 60.7% decrease in SEU cross-section is observed under 181Ta35+ irradiation when TSOI1 is reduced from 65 nm to 45 nm. Moreover, a negative back-gate bias enhances the radiation hardness of the SRAM, achieving a 71% reduction in the SEU cross-section under 181Ta35+ ion exposure following a TID of 1000 krad(Si). Consequently, an optimized biasing scheme is proposed to balance the trade-offs between radiation hardness and key circuit performance metrics, including access time, area, and power consumption. The underlying physical mechanisms are further elucidated through TCAD and HSPICE simulations.