10 April 2024 in IEEE Transactions on Microwave Theory and Techniques
A back-to-back reentrant cavity resonator (BTB RECR) in substrate integrated waveguide (SIW) configuration is integrated with a negative resistance oscillation (NRO) circuit to implement an SIW BTB RECR NRO-based active sensor for self-sustained sensing application. The dependence of sensitivity on the polarization between the dielectric sample and the induced E -field of the passive SIW BTB RECR is investigated to obtain sensitivity as high as possible. A multitask LabVIEW-based real-time test system, which can avoid disassembly and ensure the reliability of the measured results, is built up to selectively measure for transmission coefficient S $_{{21}}$ and frequency spectrum through a microwave switch. During the process of real-time replacement of deionized (DI) water reference solution with NaCl solution in dielectric sensing channel, the in-between real-time recorded oscillation frequency is cleverly used as the frequency-modulated (FM) input signal to the delay-line-based frequency demodulator and is transferred to in-phase V $_{{\text{I}}}$ and quadrature V $_{{\text{Q}}}$ dc voltages. Then, the modulated V $_{{\text{I}}}$ and V $_{{\text{Q}}}$ dc voltages are postprocessed into phase angle by using arctangent algorithm, and the phase angle in stable convergence state is finally used as response parameter for self-sustaining measurement for the concentration of NaCl solution. The NRO-based active sensor demonstrates a phase angle self-shift noise of 7.8 $^{\circ}$ and a high-resolution detection to NaCl solution at low concentration level from 2.5 to 80 mM/L and high concentration level from 100 to 800 mM/L. The measured minimum detectable lower limit concentration is 2.5 mM/L, and maximum sensitivity is 40 kHz/mM $\cdot$ L $^{{-1}}$ (0.31 $^{\circ}$ /mM $\cdot$ L $^{{-1}}$ ).
19 September 2023 in IEEE Sensors Journal
In this paper, a back-to-back (BTB) substrate integrated waveguide (SIW) re-entrant cavity resonator (RECR) is proposed to perform volatile organic compound (VOC) gas detection at room temperature. First, the structural parameters are optimized by FDTD simulation to obtain high Q-factor and sensitivity. The strongly induced E-field can be further highly concentrated between two BTB capacitive posts, which can effectively improve the filling factor and enhance the interaction of the induced E-field with the material under test (MUT). Secondly, polydimethylsiloxane (PDMS) as a VOC gas sensitive material is deposited in the gap sensing area, where strongly induced E-field is highly concentrated, to achieve high sensitivity to VOC gas when VOC gas penetrates into the pores distributed in the PDMS, resulting in the change of the permittivity of the PDMS due to the swelling of the PDMS. Finally, by injecting VOC gases such as isopropyl alcohol (IPA), ethanol and acetone gas into the sensing bottle, it is experimentally verified that the proposed sensor demonstrates good stability, reliability and repeatability during the VOC gas absorption and recovery process. The sensitivities demonstrated by the sensor for IPA, ethanol and acetone gases are 7.82 kHz/ppm, 4.58 kHz/ppm and 9.78 kHz/ppm, respectively, and the limit of detection (LOD) for IPA, ethanol and acetone gases are 292 ppm, 498 ppm and 233 ppm, respectively. The measured results indicate that the sensor demonstrates a great potential for highly sensitive detection to VOC gas concentration in air at room temperature and variable relative humidity (RH).
1 January 2026 in IEEE Transactions on Instrumentation and Measurement