Lang Yang

Lang Yang

Auto-generated profile, based on publicly available information

Lang Yang

Southwest University

Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 August 2025 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
JHJie Huang
Jie Huang
QZQian Zhao
Qian Zhao
YWYongfeng Wu
Yongfeng Wu
SHShiheng Hu
Shiheng Hu
LYLang Yang
Lang Yang
HYHongtao Yue
Hongtao Yue
A novel shorted coaxial-line resonator (SCR) in substrate integrated waveguide (SIW) configuration is integrated with a negative resistance circuit (NRC) to implement an ultrahigh Q-factor injection-locked-oscillation (ILO)-based active sensor for high-resolution detection to an ultralow magnetic nanoparticles (MNPs) content in water-based ferrofluid (WFF). Two microfluidic chips, one of which is etched for a dielectric sensing channel and the other for a magnetic sensing channel, are embedded into the highly concentrated time harmonic E-field and H-field distributions region of the SIW SCR ILO-based active sensor, respectively. Then, WFF with different MNPs content is injected into the dielectric and magnetic sensing channels, and its dielectric and magnetic properties are used to detect the MNPs content, respectively. During the solution replacement, the corresponding ILO frequency shifts are recorded in real time by the LabVIEW-based ILO frequency monitoring system, and then the ILO frequency shifts in a stable convergence state are used to characterize the MNPs content in these two sensing channels. The minimum MNPs content in WFF detected by utilizing both electrical and magnetic properties is 0.25%. Besides, a radially magnetized cylindrical magnet is cleverly embedded in the hollow inner conductor of the SCR to capture MNPs flowing through the magnetic sensing channel. Then, the MNPs will be gradually concentrated in the whole magnetic sensing channel due to the enrichment effects, and the corresponding ILO frequency shift rate is used as the response parameter to further improve the minimum detectable MNPs content to 0.125%.

1 January 2026 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
LYLang Yang
Lang Yang
ASAo Shen
Ao Shen
QZQian Zhao
Qian Zhao
HYHongtao Yue
Hongtao Yue
PCPufeng Chen
Pufeng Chen
JHJie Huang
Jie Huang