24 November 2021 in Journal of Orthopaedic Surgery and Research
Background: Split fractures of the humeral greater tuberosity (HGT) are common injuries. Although there are numerous surgical treatments for these fractures, no classification system combining clinical and biomechanical characteristics has been presented to guide the choice of fixation method. Methods: We created a standardised fracture of the HGT in 24 formalin-fixed cadavers. Six were left as single-fragment fractures (Group A), six were further prepared to create single-fragment with medium size full-thickness rotator cuff tear (FT-RCT) fractures (Group B), six were cut to create multi-fragment fractures (Group C), and six were cut to create multi-fragment with FT-RCT fractures (Group D). Each specimen was fixed with a shortened proximal humeral internal locking system (PHILOS) plate. The fixed fractures were subjected to load and load-to-failure tests and the differences between groups analysed. Results: The mean load-to-failure values were significantly different between groups (Group A, 446.83 ± 38.98 N; Group B, 384.17 ± 36.15 N; Group C, 317.17 ± 23.32 N and Group D, 266.83 ± 37.65 N, P < 0.05). The load-to-failure values for fractures with a greater tuberosity displacement of 10 mm were significantly different between each group (Group A, 194.00 ± 29.23 N; Group B, 157.00 ± 29.97 N; Group C, 109.00 ± 17.64 N and Group D, 79.67.83 ± 15.50 N; P < 0.05). These findings indicate that fractures with a displacement of 10 mm have different characteristics and should be considered separately from other HGT fractures when deciding surgical treatment. Conclusions: Biomechanical classification of split fractures of the HGT is a reliable method of categorising these fractures in order to decide surgical treatment. Our findings and proposed system will be a useful to guide the choice of surgical technique for the treatment of fractures of the HGT.
1 January 2026 in IEEE Transactions on Instrumentation and Measurement
21 August 2025 in IEEE Transactions on Instrumentation and Measurement
A novel shorted coaxial-line resonator (SCR) in substrate integrated waveguide (SIW) configuration is integrated with a negative resistance circuit (NRC) to implement an ultrahigh Q-factor injection-locked-oscillation (ILO)-based active sensor for high-resolution detection to an ultralow magnetic nanoparticles (MNPs) content in water-based ferrofluid (WFF). Two microfluidic chips, one of which is etched for a dielectric sensing channel and the other for a magnetic sensing channel, are embedded into the highly concentrated time harmonic E-field and H-field distributions region of the SIW SCR ILO-based active sensor, respectively. Then, WFF with different MNPs content is injected into the dielectric and magnetic sensing channels, and its dielectric and magnetic properties are used to detect the MNPs content, respectively. During the solution replacement, the corresponding ILO frequency shifts are recorded in real time by the LabVIEW-based ILO frequency monitoring system, and then the ILO frequency shifts in a stable convergence state are used to characterize the MNPs content in these two sensing channels. The minimum MNPs content in WFF detected by utilizing both electrical and magnetic properties is 0.25%. Besides, a radially magnetized cylindrical magnet is cleverly embedded in the hollow inner conductor of the SCR to capture MNPs flowing through the magnetic sensing channel. Then, the MNPs will be gradually concentrated in the whole magnetic sensing channel due to the enrichment effects, and the corresponding ILO frequency shift rate is used as the response parameter to further improve the minimum detectable MNPs content to 0.125%.