Valerio Ianniciello

Valerio Ianniciello

Auto-generated profile, based on publicly available information

Valerio Ianniciello

The BioRobotics Institute Scuola Superiore Sant’Anna, Pisa 56127, Italy

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 September 2024 in Science Robotics
Verified
Journal Article
Closed access
Marta GherardiniMarta Gherardini
Marta Gherardini
VIValerio Ianniciello
Valerio Ianniciello
FMFederico Masiero
Federico Masiero
FPFlavia Paggetti
Flavia Paggetti
DDDaniele D’aCcolti
Daniele D’aCcolti
CCChristian Cipriani
Christian Cipriani
The loss of a hand disrupts the sophisticated neural pathways between the brain and the hand, severely affecting the level of independence of the patient and the ability to carry out daily work and social activities. Recent years have witnessed a rapid evolution of surgical techniques and technologies aimed at restoring dexterous motor functions akin to those of the human hand through bionic solutions, mainly relying on probing of electrical signals from the residual nerves and muscles. Here, we report the clinical implementation of an interface aimed at achieving this goal by exploiting muscle deformation, sensed through passive magnetic implants: the myokinetic interface. One participant with a transradial amputation received an implantation of six permanent magnets in three muscles of the residual limb. A truly self-contained myokinetic prosthetic arm embedding all hardware components and the battery within the prosthetic socket was developed. By retrieving muscle deformation caused by voluntary contraction through magnet localization, we were able to control in real time a dexterous robotic hand following both a direct control strategy and a pattern recognition approach. In just 6 weeks, the participant successfully completed a series of functional tests, achieving scores similar to those achieved when using myoelectric controllers, a standard-of-care solution, with comparable physical and mental workloads. This experience raised conceptual and technical limits of the interface, which nevertheless pave the way for further investigations in a partially unexplored field. This study also demonstrates a viable possibility for intuitively interfacing humans with robotic technologies.

19 October 2023 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Open access
VIValerio Ianniciello
Valerio Ianniciello
Marta GherardiniMarta Gherardini
Marta Gherardini
CCChristian Cipriani
Christian Cipriani
Objective : The search for a physiologically appropriate interface for the control of dexterous hand prostheses is an ongoing challenge in bioengineering. In this context, we proposed an interface, named myokinetic control interface , based on the localization of magnets implanted in the residual limb muscles, to monitor their contractions and send appropriate commands to the artificial hand. As part of such concept, this interface requires a transcutaneous magnet localizer that can be integrated in a self-contained limb prosthesis, a feature yet to be realized within the current state of the art. Methods: In an attempt to cover this gap, here we present a modular embedded system consisting of a computation unit able to acquire synchronized samples captured by up to eight acquisition units, so to localize multiple magnets. Results: The system exhibits short computation times (<60ms) and power consumption (0.6-1.2W) which are suitable for use in a clinically viable prosthetic arm. The system proved able to localize magnets while moving at speeds in the range of physiological movements (<0.24m/s), with high accuracy (<1mm) and precision (<0.5mm). Conclusion: We demonstrated a system suitable for the implementation of a self-contained myokinetic prosthetic hand. Significance: These results pave the way towards the clinical implementation of the myokinetic interface, with amputees controlling an artificial arm by means of implanted magnets.

17 July 2019 in Sensors
Verified
Journal Article
Open access
PDF file
FCFrancesco CLEMENTE
Francesco CLEMENTE
VIValerio Ianniciello
Valerio Ianniciello
Marta GherardiniMarta Gherardini
Marta Gherardini
CCChristian Cipriani
Christian Cipriani
The quest for an intuitive and physiologically appropriate human machine interface for the control of dexterous prostheses is far from being completed. In the last decade, much effort has been dedicated to explore innovative control strategies based on the electrical signals generated by the muscles during contraction. In contrast, a novel approach, dubbed myokinetic interface, derives the control signals from the localization of multiple magnetic markers (MMs) directly implanted into the residual muscles of the amputee. Building on this idea, here we present an embedded system based on 32 magnetic field sensors and a real time computation platform. We demonstrate that the platform can simultaneously localize in real-time up to five MMs in an anatomically relevant workspace. The system proved highly linear (R2 = 0.99) and precise (1% repeatability), yet exhibiting short computation times (4 ms) and limited cross talk errors (10% the mean stroke of the magnets). Compared to a previous PC implementation, the system exhibited similar precision and accuracy, while being ~75% faster. These results proved for the first time the viability of using an embedded system for magnet localization. They also suggest that, by using an adequate number of sensors, it is possible to increase the number of simultaneously tracked MMs while introducing delays that are not perceivable by the human operator. This could allow to control more degrees of freedom than those controllable with current technologies.

21 November 2024 in IEEE Transactions on Medical Robotics and Bionics
Verified
Journal Article
Open access
FMFederico Masiero
Federico Masiero
VIValerio Ianniciello
Valerio Ianniciello
RRRoberto Raeli
Roberto Raeli
Edoardo SinibaldiEdoardo Sinibaldi
Edoardo Sinibaldi
Lorenzo MasiaLorenzo Masia
Lorenzo Masia
CCChristian Cipriani
Christian Cipriani
Tracking permanent magnets represents a low-footprint and passive approach to monitoring objects or human motion by attaching or embedding magnets therein. Recent tracking techniques achieved high-bandwidth detection considering a simplified model for the magnetic sources, i.e. the dipole model. Nonetheless, such a model can lead to inaccurate results any time a non-spherical magnet approaches the sensor array. Here, we present a novel tracking algorithm based on an analytical model for permanent magnet cylinders with uniform arbitrary magnetization. By means of a physical system mounting 20 magnetometers, we compared the tracking accuracy obtained with our algorithm vs. results obtained by using the dipole model and with respect to a ground-truth reference. With a single magnetic target, our algorithm can significantly lower position (up to 0.68 mm) and orientation errors (up to 2.5∘) while enabling online tracking (computation time below 19 ms). We also accurately tracked two magnets, by obtaining a reduction in position error (up to 0.92 mm) vs. the dipole-based algorithm. These findings broaden the applicability of accurate magnetic tracking to real-time applications, facilitating the tracking of multiple magnetic targets in proximity of the magnetic sensors. This advancement opens avenues for applications in wearable devices, advancing the field of motion detection beyond traditional inertial measurement units.

30 January 2025 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Open access
FPFlavia Paggetti
Flavia Paggetti
Marta GherardiniMarta Gherardini
Marta Gherardini
VIValerio Ianniciello
Valerio Ianniciello
SCSimone Cirelli
Simone Cirelli
CCChristian Cipriani
Christian Cipriani
Objective: The myokinetic control interface for limb protheses involves implanting small permanent magnets in the residual muscles of the stump, retrieving their displacement induced by muscle contraction using external magnetic sensors, and mapping such displacements to motor commands. We have previously shown the feasibility of tracking several magnets implanted in an anatomically relevant workspace. However, to clinically translate the interface, strategies to address different kinds of external disturbances compromising its functioning are mandatory. Among these, physical disturbances, viz. relative displacement between the sensors and the magnets not due to voluntary contraction, could significantly hinder the interface usability. Methods: Here we propose three rejection methods sought to mitigate this problem: one aims to realign the sensors and the magnets when a disturbance is detected, through numerical approximation methods; the others exploit differential measurements. We applied these concepts to upper limb prostheses, by mimicking the presence of physical disturbances in simulations and through a physical setup, reproducing four target muscles of a human forearm to be potentially implanted. Finally, we evaluated the rejection ability of one of those methods during the first-in-human implementation of the myokinetic interface. Results: All methods proved capable of rejecting the disturbances, showing median localization errors below 10% the displacement undergone during contraction. Conclusion: Results suggest that the optimal rejection method is application-specific, and provide hints for assessing different factors influencing the best choice. Significance: Other than being crucial for the myokinetic interface development, these outcomes also provide interesting insights for many biomedical applications exploiting remote magnetic tracking.

8 March 2024 in Advanced Intelligent Systems
Verified
Journal Article
Open access
FMFederico Masiero
Federico Masiero
EFEliana La Frazia
Eliana La Frazia
VIValerio Ianniciello
Valerio Ianniciello
CCChristian Cipriani
Christian Cipriani
Extensive efforts in providing upper limb amputees with sensory feedback have primarily focused on the restoration of tactile capabilities, while challenges in evoking proprioceptive sensations have been poorly addressed. Previously, an human–machine interface (HMI) was proposed based on permanent magnets implanted in residual muscles of an amputee, namely the myokinetic interface, to control robotic limb prostheses. Besides control, implanted magnets offer an unprecedent opportunity to trigger musculotendon proprioceptors via untethered selective vibrations. Herein, the challenge of tracking multiple moving magnets is addressed (e.g., following muscle contractions) while being vibrated by controlled magnetic fields produced by external coils. Results demonstrate the viability of a real‐time (RT) system capable of simultaneously tracking and vibrating multiple moving magnets within a three‐dimensional workspace. Highly selective torsional vibrations in the frequency span eliciting movement illusions (70, 80, and 90 Hz) are achieved on two moving magnets, with efficiencies above 0.82 (over 80% of spectral power at the desired frequency). Tracking accuracy and precision remain robust to the coil magnetic field, with position median errors below 1.2 mm and median displacement errors below 0.95 mm. This study represents a crucial step towards the development of a bench system to study proprioception in humans.