25 September 2024 in Science Robotics
The loss of a hand disrupts the sophisticated neural pathways between the brain and the hand, severely affecting the level of independence of the patient and the ability to carry out daily work and social activities. Recent years have witnessed a rapid evolution of surgical techniques and technologies aimed at restoring dexterous motor functions akin to those of the human hand through bionic solutions, mainly relying on probing of electrical signals from the residual nerves and muscles. Here, we report the clinical implementation of an interface aimed at achieving this goal by exploiting muscle deformation, sensed through passive magnetic implants: the myokinetic interface. One participant with a transradial amputation received an implantation of six permanent magnets in three muscles of the residual limb. A truly self-contained myokinetic prosthetic arm embedding all hardware components and the battery within the prosthetic socket was developed. By retrieving muscle deformation caused by voluntary contraction through magnet localization, we were able to control in real time a dexterous robotic hand following both a direct control strategy and a pattern recognition approach. In just 6 weeks, the participant successfully completed a series of functional tests, achieving scores similar to those achieved when using myoelectric controllers, a standard-of-care solution, with comparable physical and mental workloads. This experience raised conceptual and technical limits of the interface, which nevertheless pave the way for further investigations in a partially unexplored field. This study also demonstrates a viable possibility for intuitively interfacing humans with robotic technologies.
3 September 2021 in IEEE Sensors Journal
Magnetic tracking systems have been widely investigated in biomedical engineering due to the transparency of the human body to static magnetic fields. We recently proposed a novel human-machine interface for prosthetic application, namely the myokinetic interface. This controls multi-articulated prostheses by tracking magnets implanted in the residual muscles of individuals with amputation. Previous studies in this area focused solely on the choice and tuning of the localization algorithm. Here, we addressed the role of the intrinsic properties of the sensors, by analysing their effects on the tracking accuracy and on the computation time of the localization algorithm, through experimentally-verified computer simulations. We observed that the tracking accuracy is primarily affected by the localization rate, which is directly related to the sampling frequency of the sensors, and less significantly affected by the sensor resolution. The computation time, instead, proved positively correlated to the number of MMs, and negatively correlated with the localization rate. Our results may contribute to the development of novel human-machine interfaces for prosthetic limbs and could be extended to a broad range of applications involving magnetic tracking.
17 July 2023 in Advanced Science
Magnetic systems based on permanent magnets are receiving growing attention, in particular for micro/millirobotics and biomedical applications. Their design landscape is expanded by the possibility to program magnetization, yet enabling analytical results, crucial for containing computational costs, are lacking. The dipole approximation is systematically used (and often strained), because exact and computationally robust solutions are to be unveiled even for common geometries such as cylindrical magnets, which are ubiquitously used in fundamental research and applications. In this study, exact solutions are disclosed for magnetic field and gradient of a cylindrical magnet with generic uniform magnetization, which can be robustly computed everywhere within and outside the magnet, and directly extend to magnets systems of arbitrary complexity. Based on them, exact and computationally robust solutions are unveiled for force and torque between coaxial magnets. The obtained analytical solutions overstep the dipole approximation, thus filling a long‐standing gap, and offer strong computational gains versus numerical simulations (up to 106, for the considered test‐cases). Moreover, they bridge to a variety of applications, as illustrated through a compact magnets array that could be used to advance state‐of‐the‐art biomedical tools, by creating, based on programmable magnetization patterns, circumferential and helical force traps for magnetoresponsive diagnostic/therapeutic agents.
21 September 2020 in IEEE Transactions on Neural Systems and Rehabilitation Engineering
We recently introduced the concept of a new human-machine interface (the myokinetic control interface) to control hand prostheses. The interface tracks muscle contractions via permanent magnets implanted in the muscles and magnetic field sensors hosted in the prosthetic socket. Previously we showed the feasibility of localizing several magnets in non-realistic workspaces. Here, aided by a 3D CAD model of the forearm, we computed the localization accuracy simulated for three different below-elbow amputation levels, following general guidelines identified in early work. To this aim we first identified the number of magnets that could fit and be tracked in a proximal (T1), middle (T2) and distal (T3) representative amputation, starting from 18, 20 and 23 eligible muscles, respectively. Then we ran a localization algorithm to estimate the poses of the magnets based on the sensor readings. A sensor selection strategy (from an initial grid of 840 sensors) was also implemented to optimize the computational cost of the localization process. Results showed that the localizer was able to accurately track up to 11 (T1), 13 (T2) and 19 (T3) magnetic markers (MMs) with an array of 154, 205 and 260 sensors, respectively. Localization errors lower than 7% the trajectory travelled by the magnets during muscle contraction were always achieved. This work not only answers the question: “how many magnets could be implanted in a forearm and successfully tracked with a the myokinetic control approach?”, but also provides interesting insights for a wide range of bioengineering applications exploiting magnetic tracking.
9 February 2023 in IEEE Transactions on Neural Systems and Rehabilitation Engineering
Recent studies on human upper limb motion highlighted the benefit of dimensionality reduction techniques to extrapolate informative joint patterns. These techniques can simplify the description of upper limb kinematics in physiological conditions, serving as a baseline for the objective assessment of movement alterations, or to be implemented in a robotic joint. However, the successful description of kinematic data requires a proper alignment of the acquisitions to correctly estimate kinematic patterns and their motion variability. Here, we propose a structured methodology to process and analyze upper limb kinematic data, considering time warping and task segmentation to register task execution on a common normalized completion time axis. Functional principal component analysis (fPCA) was used to extract patterns of motion of the wrist joint from the data collected by healthy participants performing activities of daily living. Our results suggest that wrist trajectories can be described as a linear combination of few functional principal components (fPCs). In fact, three fPCs explained more than 85% of the variance of any task. Wrist trajectories in the reaching phase of movement were highly correlated among participants and significantly more than trajectories in the manipulation phase (p<0.01). These findings may be useful in simplifying the control and design of robotic wrists, and could aid the development of therapies for the early detection of pathological conditions.
21 November 2024 in IEEE Transactions on Medical Robotics and Bionics
Tracking permanent magnets represents a low-footprint and passive approach to monitoring objects or human motion by attaching or embedding magnets therein. Recent tracking techniques achieved high-bandwidth detection considering a simplified model for the magnetic sources, i.e. the dipole model. Nonetheless, such a model can lead to inaccurate results any time a non-spherical magnet approaches the sensor array. Here, we present a novel tracking algorithm based on an analytical model for permanent magnet cylinders with uniform arbitrary magnetization. By means of a physical system mounting 20 magnetometers, we compared the tracking accuracy obtained with our algorithm vs. results obtained by using the dipole model and with respect to a ground-truth reference. With a single magnetic target, our algorithm can significantly lower position (up to 0.68 mm) and orientation errors (up to 2.5∘) while enabling online tracking (computation time below 19 ms). We also accurately tracked two magnets, by obtaining a reduction in position error (up to 0.92 mm) vs. the dipole-based algorithm. These findings broaden the applicability of accurate magnetic tracking to real-time applications, facilitating the tracking of multiple magnetic targets in proximity of the magnetic sensors. This advancement opens avenues for applications in wearable devices, advancing the field of motion detection beyond traditional inertial measurement units.