LLC -DC transformers ( LLC -DCXs) operate under fixed-frequency and open-loop conditions to achieve high efficiency and are promising converters that can be used in the auxiliary power units (APUs) of electric locomotives. An optimal design method of LLC -DCXs is proposed in this paper. First, the time-domain expressions of the symmetric half-bridge LLC resonant converter with split resonant capacitors are derived. A current increment method is proposed to determine the expressions. Second, the discontinuous conduction mode (DCM) and voltage gain limiting conditions are used to obtain the magnetizing inductance ranges. The converter losses and zero-voltage-switching (ZVS) ranges are considered to determine the final magnetizing inductance. A 10 kW prototype is used as an example, and a detailed parameter design process is implemented. Compared with conventional design methods for the magnetizing inductance, the proposed method can effectively determine the maximum magnetizing inductance for the DCM operation of the converter. The effectiveness of the proposed method is proven by the simulations and experimental results obtained for the 10 kW LLC -DCX prototype. The maximum efficiency of the designed converter is 98.12% under the full load.
9 April 2020 in IEEE Transactions on Industrial Electronics
In the maglev train electric drive system, the linear electric machine is a welcome solution. However, for long railways, the mover position measurement is an issue, especially when the train speed is very high, e.g. 600 km/h. The position measurement method of the mover must be simple and precise at high speeds while maintaining a low cost for industrial applications. The principle of the stator permanent magnet (stator-PM) machine provides evidence that the magnets and windings can be mounted on the mover of the linear resolver, leaving a simple secondary side structure on the railway. With this idea, this paper presents a PM linear resolver that generates orthogonal back-EMFs as the SIN/COS signals. The train position can then be measured by decoding the PM back-EMF. On the other hand, the high-frequency injection is imposed to solve the mover position measurement at zero- and low-speed. This PM linear resolver is prototyped with PCB windings instead of regular coil windings. The dedicated decoding firmware is developed to evaluate the measurement performance up to 60 km/h in the lab setup.
17 May 2024 in IEEE Transactions on Power Electronics
The $R_{\text{on}}/R_{\text{off}}$ model provides high accuracy in the real-time simulation of high-switching-frequency power electronic converters. However, the iterative operations limit the application of the $R_{\text{on}}/R_{\text{off}}$ model in high-switching-frequency domains. This article presents a novel noniterative method for determining the switch statuses of half-bridge arms. By predicting the state variables and correcting the switch status combinations in the natural commutation process with the status switching principle, the accurate switch status can be obtained. Besides, this method adopts the backward Euler method to ensure the system stability and realizes the decoupling among the half-bridge arms, which greatly reduces the modeling complexity and calculation amount when judging the switch status. Finally, an ac–dc–ac topology with 100-kHz switching frequency and an $LLC$ resonant converter with 250-kHz switching frequency are implemented on a field-programmable gate array (FPGA). The parallel solving architecture enables simulation time step as low as 25 ns. The results derived from the real-time simulation and hardware experiment corroborate low FPGA resource consumption and high precision of the proposed method.
The hardware‐in‐the‐loop (HIL) real‐time simulation for high‐speed train electrical traction system aims to reduce the design cost and speed up control verification process of algorithms in the developmental stage of the traction control unit. In this study, based on the dSPACE real‐time simulator, the multiple‐simulator, multiple‐simulation step of HIL real‐time simulation system is first built. Second, for the associated discrete circuit modelling method, an optimisation method is proposed to minimise the switching loss and improve the simulation accuracy by selecting the optimal discrete‐time switch admittance parameter, GS . To decrease the computational burden for field‐programmable gate array (FPGA), a decoupling method without simulation latency is presented to reduce the matrix dimension of the system model. Finally, the real‐time simulation models of electrical traction system are realised by CPU + FPGA‐based simulator, in which the power electronics converter models are computed in FPGA with a fixed 100 ns time‐step. The validity and reliability of the real‐time simulation system is verified by the HIL simulation and experimental results, which indicate that the real‐time HIL simulation at the nanosecond level improves the accuracy essentially.
This letter presents a real-time simulation method for bridge-based power electronic converters based on the Ron/Roff model. By constructing the equivalent system state equation, all multiplications can be performed by shift addition operations in field programmable gate array (FPGA) implementation and avoids using limited multipliers. Then, a 50-kHz dual active bridge converter and a 100-kHz ac-dc–ac converter are simulated on FPGA with 20 ns simulation time step. Accuracy, timing, and resource consumption results verify the effectiveness of this method.