Pipe height in cylindrical neutron moderator is an important factor to flow pattern, temperature distribution and even the neutron characters. In this paper, the steady-state thermal analysis of cold neutron moderator is carrying out with different heights, conjugated heat transfer method and one-way coupled with a neutron transfer software. The different pipe heights, which is the jet-to-surface distances (H/D = 0.5~6), were compared using a 2D moderator model. The results show that vortex size and velocity gradient from container wall to vortex center vary with H/D, the center of recirculation zone nearly remain constant, and heat transfer effect is weakened on the target bottom surface. With H/D increasing, the velocity at bottom target surface is progressively decreased, and cooling effect is poor, leading to the rise in temperature. The optimal range cooling performance is (H/D) = 0.5~1 at Re = 1.7 × 105, and the enhancement of beam power further strengthens the thermal deposition difference between container and liquid hydrogen. The results can be applied to moderator component design and optimization in the future spallation neutron source.
The flow field distribution and thermal properties of supercritical hydrogen are crucial factors affecting the quality of neutrons output from spallation neutron source, which may contribute to the optimization design of the moderator. Several sensitivity studies on affecting heat transfer characteristics of liquid hydrogen inside a moderator were executed, and a choice was made to use a computational fluid dynamics method for numerical simulation. The sensitivity degree of factors affecting the heat transfer characteristics of liquid hydrogen are in sequence of inlet mass flow, beam power and operating pressure. Especially when the beam power is 500 kW (the temperature range of liquid hydrogen is about 20~30 K); where the effect of mass flow rate is remarkable, the cooling effect is best in the range of 60~90 g/s × 394 mm2. Meanwhile, the maximum temperature of liquid hydrogen is close to the bottom recirculation zone due to the influence of the flow field and the heat deposition distribution of the poisoned plate. The effect of variable pressure on the temperature of liquid hydrogen is not significant, whereas the sudden rise of wall temperature is observed near the large specific heat region of 15 bar.
In recent years, an increasing number of national major projects have focused on the physicochemical properties of materials and the structural integrity of components in cryogenic environments. In situ neutron non-destructive testing offers a distinct advantage for scientific research conducted under cryogenic conditions. With the progressive advancement of neutron sources and neutron diffraction techniques, neutron probes have become indispensable for the in situ observation of lattice strain, phase transformation behavior, and residual stresses in materials at cryogenic temperatures. Based on the energy-resolved neutron imaging instrument (ERNI) at Beamline 13 of the China Spallation Neutron Source (CSNS), we have developed a cryogenic loading frame for in situ neutron diffraction tensile tests. This paper presents a detailed description of the mechanical structural design, cooling and control system, strength and thermal analyses, and experimental validation of the device. The apparatus enables in situ neutron diffraction experiments over a wide temperature range of 6–473 K, with an axial loading capacity of 50 kN. Furthermore, the device was employed to conduct in situ neutron diffraction measurements on austenitic 304 stainless steel at both room and cryogenic temperatures. The experimental results confirm that this equipment exhibits stable loading capability and precise temperature control, ensuring the reliability of the experimental data.