Qingan Ma

Qingan Ma

Auto-generated profile, based on publicly available information

Qingan Ma

School of Electrical Engineering, Southwest Jiaotong University, Chengdu, China

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2024 in IEEE Transactions on Transportation Electrification
Verified
Journal Article
Closed access
JZJian Zhang
Jian Zhang
Wei LiuWei Liu
Wei Liu
ZTZhongbei Tian
Zhongbei Tian
QXQian Jiaotong Xu
Qian Jiaotong Xu
QMQingan Ma
Qingan Ma
ZPZiqiang Pan
Ziqiang Pan
The onboard braking resistance (OBR) is widely installed on urban rail trains. The general trend is to cancel OBR in urban rail, due to the low efficiency of using regenerative braking energy. The design of Energy feedback systems (EFSs) after canceling OBR is important because EFSs need to balance energy-saving effects and network voltage safety. Besides, the pneumatic braking may increase, so the brake shoe life needs to be further studied. In this paper, the electro-pneumatic braking and braking shoe wear models are first built. Then the power supply calculation algorithm considering OBR is proposed, including the train dynamic model, train brake power distribution rule, and power supply calculation algorithm. Next, the EFS optimal design after canceling OBR is discussed. The comprehensive cost includes the cost of changing braking shoes. A case study denotes that up to 20.5 MWh or 18.5% of the traction energy can be saved per day after canceling OBR and setting EFSs at each traction substation. The brake shoe life will be 92~159 days. In CLC/TR 50646, after canceling OBR, EFS should be installed at each TS. The optimal result does not follow the rule but can save at least 7.6% of the total cost compared with the actual project.

27 January 2025 in IEEE Transactions on Transportation Electrification
Verified
Journal Article
Closed access
ABAshfaque Ahmed Bhatti
Ashfaque Ahmed Bhatti
Wei LiuWei Liu
Wei Liu
MLMingze Li
Mingze Li
QMQingan Ma
Qingan Ma
QXQian Jiaotong Xu
Qian Jiaotong Xu
XZXiaodong Zhang
Xiaodong Zhang
In dual-traction power supply system (DTPSS), an improper value of onboard grounding resistance could result in a larger current distribution, axle end potential, and surge over-voltage (SOV) of the vehicle body (VB) because of the interaction between the AC and DC traction power supply system and the train crossing the neutral sections. Therefore, it is important to carefully select the appropriate value of the resistance and position of the grounding points. This research article proposed the steady-state model of DTPSS to evaluate the current distribution and axle-end potential, and the transient state model of DTPSS to calculate the SOV of the VB of vehicle grounding systems (VGS). To obtain the best optimal solution, the particle swarm optimization (PSO) and the technique for order of preference by similarity to ideal solution (TOPSIS) multi-objective optimization techniques have been implemented. The accuracy and efficiency of the VB current distribution are verified by observing the experimental and simulation results. The proposed VGS optimization technique demonstrates that the VB current distribution has achieved a significant improvement of 24.8% of the total current in the DC section and 21.1% of the total current in the AC section. By observing experimental, simulation, and optimal solutions of transient models in DTPSS, the SOV value was reduce to 33.4% of the total voltage.

4 July 2018 in Journal of Modern Transportation
Verified
Journal Article
Open access
PDF file
QMQing-An Ma
Qing-An Ma
WLWei Liu
Wei Liu
To improve the accuracy of fault location system, several short-circuit tests need to be conducted before being brought into service in autotransformer (AT) feeding systems for high-speed railways in China. However, no systematic algorithm yet exists to evaluate the consistency of the current distribution of short-circuit tests. A methodology is proposed in this paper to address this problem. Based on Kirchhoff’s current law and the generalized method of symmetrical components, the current deviations of the AT feeding systems are analysed and then normalized with the short-circuit current as they vary greatly with systems and short-circuit sites. It is also found that the short-circuit current varies with the calculation methods, and its unbiased standard deviation also reflects the consistency of the short-circuit test. The mean and maximum of the current deviations, as well as the unbiased standard deviation of the short-circuit current, show the consistency of the short-circuit test from different aspects, although the last two items are highly relevant. Therefore, a unified evaluation index is defined as the sum of the three items, and then applied in two case studies to test its performance. The results show that, the proposed index can clearly distinguish the consistency of the short-circuit tests and may be used to sort the short-circuit tests for fault location systems. Besides, some short-circuit tests may have very poor consistency indices, and thus are not applicable to the tuning of fault location systems. In the authors’ opinion, the determination of the threshold of the proposed index needs further investigation.