1 June 2026 in Journal of Instrumentation
High-energy photon beams are widely used in radiotherapy owing to their effectiveness in treating deep-seated tumors and their skin-sparing effects. However, treatment planning systems — the most common method for estimating skin dose — have been reported to deviate by as much as 34% from measurements, potentially leading to various side effects. To address this issue, numerous studies have explored skin dosimeters for direct skin dose measurement. However, many of these are limited in clinical applicability because they rely on highly toxic materials such as lead and mercury. In this study, a skin dosimeter based on BaTiO 3 — a nearly non-toxic material — was fabricated, and its fundamental response to high-energy photon beams was evaluated to assess its feasibility for practical applications. The dosimeter was tested for linearity, repeatability, dose-rate dependence, and percent-depth-dose (PDD) conformity. The results demonstrated excellent linearity and repeatability, along with consistent performance across varying dose rates. However, although the dosimeter exhibited excellent D max conformity, the PDD 20/10 values exhibited errors greater than 3.4%, which are likely attributed to several factors, including the atomic number and energy dependence of the sensor. These findings suggest that BaTiO 3 possesses favorable electrical characteristics for use as a skin dosimeter and that a clinically viable device may be achievable through further studies.
25 June 2026 in Physica Status Solidi (a)
High‐dose‐rate brachytherapy (HDR‐BT) delivers radiation using a radioactive source positioned close to the tumor, enabling highly localized dose distributions. However, patient‐specific quality assurance (PSQA) methods for HDR‐BT remain limited due to the radial nature of source irradiation and the lack of suitable dosimetric tools. In this study, a semi‐circular multipixel dosimeter is developed as a feasibility‐level PSQA detector for HDR‐BT. The curved geometry allows consistent control of the source‐to‐dosimeter distance and enables the measurement of radial dose variations around a 192 Ir source. The dosimeter performance is evaluated in terms of repeatability, dose linearity, and distance dependence. The experimental results demonstrate stable repeatability with a coefficient of variation of 0.4399%, excellent linearity over a dose range of 5–1000 cGy (R 2 = 0.9989), and a clear distance‐dependent response consistent with geometric dose fall‐off. Monte Carlo simulations performed under identical conditions show similar trends and support the physical validity of the measured results. The observed discrepancies between measurement and simulation are attributed to environmental effects and detector‐specific nonidealities. These findings indicate that the proposed semi‐circular dosimeter has strong potential for measuring radial dose distributions and provides a foundation for developing practical PSQA systems for HDR‐BT.
1 September 2025 in Journal of Instrumentation
CsPbI3, a perovskite material, has garnered significant attention in solar cell research owing to its unique crystal structure and optimal band-gap energy. Recently, CsPbI3 has also been explored for use in dosimeters in the radiotherapeutic field. This study analyzes the reaction characteristics of CsPbI3 to the 192Ir radioisotope, focusing on how the material thickness influences performance. The aim of this study is to identify the optimal thickness and measurement conditions of CsPbI3. Before fabricating the sensor for evaluation, CsPbI3 is synthesized using CsI and PbI2 precursors. Operational voltage factors are determined by analyzing the dark current and photocurrent from four unit-cell sensors with CsPbI3 thicknesses ranging from 100 to 250 μm. These voltage factors are then applied to evaluate the linearity and repeatability in each sensor. The results of the operational voltage factor tests indicate that +2 V/μm provides optimal electrical stability and measurement efficiency. All sensors demonstrate a high linearity (R 2 > 0.9990) and satisfy the repeatability criterion (CV < 1.5%), although thicker sensors exhibit higher CV values. Notably, the 250 μm sensor has a margin of error of < 0.1% for repeatability, indicating potential challenges in maintaining performance under varying environmental conditions. Further analysis reveals a positive correlation between sensor thickness and sensitivity. Based on these findings, a +400 V operational voltage is recommended for application to a 200 μm thick sensor as the optimal condition for stable and efficient measurements with CsPbI3-based sensors. Future studies involving various radiotherapy equipment and diverse types and energies of radiation are necessary to establish comprehensive optimized conditions for radiotherapeutic quality assurance.
1 November 2025 in Journal of Instrumentation
CsPb-based perovskites are promising materials for solar cells because of their low unit production cost and high efficiency. Among them, halide materials have also attracted research attention in the field of radiation therapy. In this study, we analyzed the characteristics of CsPbI 2 Cl — a CsPb-based halide perovskite — under high-energy radiation at levels equivalent to those used in clinical therapy to evaluate its feasibility for quality assurance (QA) in radiation therapy. We fabricated a CsPbI 2 Cl-based sensor after synthesizing CsPbI 2 Cl from its precursors, i.e., CsCl and PbI 2 , and evaluated the linearity, repeatability, dose-rate dependence, and percent depth dose (PDD) under irradiation with energy of 6 and 15 MV. All the evaluated parameters except for the PDD met the criteria ( R 2 > 0.99900 and CV< 1.5%). However, PDD 20/10 , which is one of the criteria for PDD, exhibited errors of 6.34% and 3.74% for 6 and 15 MV, respectively, compared with the ionization chamber, which provides the reference value for actual QA. This may be due to the unique response characteristics of semiconductor-based dosimeters and the high atomic number of the components of CsPbI 2 Cl. According to the results, the CsPbI 2 Cl-based sensor developed in this study was evaluated for its reliability and stability against high-energy radiation, but it still needs to be improved for depth-dose measurement. With follow-up studies for improving the sensor structure and considering additional variables, we expect that this sensor can be employed as a dosimeter for clinical QA.
1 April 2026 in Journal of Instrumentation
Quality assurance (QA) in radiotherapy is essential to ensure precise dose delivery; however, conventional ionization chambers, including parallel plate chambers (PPCs), exhibit inherent structural limitations, particularly under small-field conditions. In this study, a CsPbIBr 2 -based unit-cell radiation sensor utilizing a halide perovskite material was fabricated, leveraging its capability for compact thin-film construction. The response characteristics of the sensor to high-energy electron beams (6, 9, and 12 MeV) generated by a clinical linear accelerator were systematically evaluated to assess its suitability as a clinical QA dosimeter. The fabricated sensor demonstrated stable linearity and repeatability across various irradiation conditions, maintaining consistent performance regardless of dose-rate variations. Furthermore, electron beam-quality indices derived from depth-dose curve analyses closely matched the reference values obtained with a PPC, satisfying established tolerance criteria for clinical electron beam-quality QA. These findings indicate that the CsPbIBr 2 -based sensor offers reliable and stable dosimetric performance in clinical electron beam QA settings. However, increasing deviation was observed in the low-energy region under certain conditions, which was potentially attributable to low-energy photon influence. Addressing this limitation through further investigation is necessary. With continued development, the proposed sensor holds promise as a practical dosimeter for clinical QA applications.
30 July 2026 in Physica Status Solidi (a)
In this study, we developed a flexible digital bolus dosimeter based on a polycrystalline HgI 2 photoconductor embedded in a tissue‐equivalent polydimethylsiloxane (PDMS) matrix, incorporating a 70 μm protective layer for skin‐dose evaluation. The dosimeter exhibited excellent linearity ( R 2 = 0.9996) within 2–400 MU and superior repeatability (standard deviation of 1.59%). Although the signal gradually decreased by approximately 8.3% (range from 5.6% to −2.7%) as the dose rate increased from 100 to 600 MU/min due to charge trapping and polarization, a stable response was maintained using a dose‐rate‐dependent correction factor or integrating advanced signal processing techniques. Mechanical stability tests up to 1000 bending cycles suggested the need for baseline correction on curved surfaces due to increased drift‐charge and photo‐charge. Subsequently, a 24‐pixel linear array dosimeter was fabricated on a flexible printed circuit board (fPCB) to evaluate continuous spatial dose distribution. When applied to a curved RSD chest phantom, the array reproduced consistent spatial dose distribution trends compared to radiochromic film at various gantry angles, with absolute dose differences of 3.51–7.05 cGy (7%–12%). These results demonstrate that the proposed platform is practical and suitable for evaluating skin‐dose distributions in complex geometries during radiotherapy.