Yungi Yeom

Yungi Yeom

Auto-generated profile, based on publicly available information

Yungi Yeom

Department of Radiation Oncology, College of Medicine, Inje University, 75, Bokji-ro, Busan

Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 June 2026 in Journal of Instrumentation
Verified
Journal Article
Closed access
YSYohan Shin
Yohan Shin
YYYungi Yeom
Yungi Yeom
MHMoojae Han
Moojae Han
JKJinyoung Kim
Jinyoung Kim
HCHeunglae Cho
Heunglae Cho
SPSungkwang Park
Sungkwang Park
High-energy photon beams are widely used in radiotherapy owing to their effectiveness in treating deep-seated tumors and their skin-sparing effects. However, treatment planning systems — the most common method for estimating skin dose — have been reported to deviate by as much as 34% from measurements, potentially leading to various side effects. To address this issue, numerous studies have explored skin dosimeters for direct skin dose measurement. However, many of these are limited in clinical applicability because they rely on highly toxic materials such as lead and mercury. In this study, a skin dosimeter based on BaTiO 3 — a nearly non-toxic material — was fabricated, and its fundamental response to high-energy photon beams was evaluated to assess its feasibility for practical applications. The dosimeter was tested for linearity, repeatability, dose-rate dependence, and percent-depth-dose (PDD) conformity. The results demonstrated excellent linearity and repeatability, along with consistent performance across varying dose rates. However, although the dosimeter exhibited excellent D max conformity, the PDD 20/10 values exhibited errors greater than 3.4%, which are likely attributed to several factors, including the atomic number and energy dependence of the sensor. These findings suggest that BaTiO 3 possesses favorable electrical characteristics for use as a skin dosimeter and that a clinically viable device may be achievable through further studies.

1 April 2026 in Journal of Instrumentation
Verified
Journal Article
Closed access
YSYohan Shin
Yohan Shin
MHMoojae Han
Moojae Han
YYYungi Yeom
Yungi Yeom
JCJinbeom Chung
Jinbeom Chung
SPSungkwang Park
Sungkwang Park
Quality assurance (QA) in radiotherapy is essential to ensure precise dose delivery; however, conventional ionization chambers, including parallel plate chambers (PPCs), exhibit inherent structural limitations, particularly under small-field conditions. In this study, a CsPbIBr 2 -based unit-cell radiation sensor utilizing a halide perovskite material was fabricated, leveraging its capability for compact thin-film construction. The response characteristics of the sensor to high-energy electron beams (6, 9, and 12 MeV) generated by a clinical linear accelerator were systematically evaluated to assess its suitability as a clinical QA dosimeter. The fabricated sensor demonstrated stable linearity and repeatability across various irradiation conditions, maintaining consistent performance regardless of dose-rate variations. Furthermore, electron beam-quality indices derived from depth-dose curve analyses closely matched the reference values obtained with a PPC, satisfying established tolerance criteria for clinical electron beam-quality QA. These findings indicate that the CsPbIBr 2 -based sensor offers reliable and stable dosimetric performance in clinical electron beam QA settings. However, increasing deviation was observed in the low-energy region under certain conditions, which was potentially attributable to low-energy photon influence. Addressing this limitation through further investigation is necessary. With continued development, the proposed sensor holds promise as a practical dosimeter for clinical QA applications.

1 November 2026 in Journal of Instrumentation
Verified
Journal Article
Closed access
PDF file
YSYohan Shin
Yohan Shin
YYYungi Yeom
Yungi Yeom
MHMoojae Han
Moojae Han
JKJinyoung Kim
Jinyoung Kim
JCJinbeom Chung
Jinbeom Chung
SPSungkwang Park
Sungkwang Park
In the field of radiation therapy, inorganic perovskites, which exhibit excellent radiation responsiveness, are attracting attention as solid-state sensor materials for precise quality assurance (QA). However, conventional nano-scale perovskite thin-films have limitations due to insufficient active volume in measuring high-energy (high-E) radiation characterized by high penetrating power. To overcome these limitations, we fabricated a micro-scale CsPbI 2 Br thick-film sensor and irradiated it with high-E electron beams of 6, 9, and 12 MeV using a clinical linear accelerator under experimental conditions closely simulating a clinical QA environment. The experimental results demonstrated that the fabricated sensor exhibited excellent linearity ( R 2 > 0.999) and repeatability (CV< 1.6%) within the dose range of 10 to 1000 MU. Furthermore, it showed a dose-rate independent response against dose-rate variations from 100 to 600 MU/min. In a comparative evaluation of the percent-depth dose (PDD) against an ionization chamber, the difference in R 50 was less than 1 mm, satisfying the clinical QA tolerance criterion. However, at deeper depths, overestimations were observed due to the photoelectric effect induced by scattered low-energy photons, which was attributed to the high atomic number of the sensor material. Additionally, this study has a limitation in evaluating long-term reliability due to the lack of proper encapsulation. In conclusion, the thick-film sensor fabricated in this study demonstrated outstanding dosimetric response characteristics. With further studies, such as the development of robust packaging techniques and compensation layers, it is highly anticipated to be widely utilized as a next-generation dosimeter for clinical radiotherapy QA.

1 November 2025 in Journal of Instrumentation
Verified
Journal Article
Closed access
YSYohan Shin
Yohan Shin
YYYungi Yeom
Yungi Yeom
SYSeungwoo Yang
Seungwoo Yang
MHMoojae Han
Moojae Han
JKJinyoung Kim
Jinyoung Kim
SPSungkwang Park
Sungkwang Park
CsPb-based perovskites are promising materials for solar cells because of their low unit production cost and high efficiency. Among them, halide materials have also attracted research attention in the field of radiation therapy. In this study, we analyzed the characteristics of CsPbI 2 Cl — a CsPb-based halide perovskite — under high-energy radiation at levels equivalent to those used in clinical therapy to evaluate its feasibility for quality assurance (QA) in radiation therapy. We fabricated a CsPbI 2 Cl-based sensor after synthesizing CsPbI 2 Cl from its precursors, i.e., CsCl and PbI 2 , and evaluated the linearity, repeatability, dose-rate dependence, and percent depth dose (PDD) under irradiation with energy of 6 and 15 MV. All the evaluated parameters except for the PDD met the criteria ( R 2 > 0.99900 and CV< 1.5%). However, PDD 20/10 , which is one of the criteria for PDD, exhibited errors of 6.34% and 3.74% for 6 and 15 MV, respectively, compared with the ionization chamber, which provides the reference value for actual QA. This may be due to the unique response characteristics of semiconductor-based dosimeters and the high atomic number of the components of CsPbI 2 Cl. According to the results, the CsPbI 2 Cl-based sensor developed in this study was evaluated for its reliability and stability against high-energy radiation, but it still needs to be improved for depth-dose measurement. With follow-up studies for improving the sensor structure and considering additional variables, we expect that this sensor can be employed as a dosimeter for clinical QA.