Saeed Samaei

Saeed Samaei

Auto-generated profile, based on publicly available information

Saeed Samaei

Western University, Department of Medical Biophysics, London, Ontario, Canada

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 June 2022 in Journal of Biomedical Optics
Verified
Journal Article
Open access
PDF file
PLPranav Lanka
Pranav Lanka
LYLin Yang
Lin Yang
DODavid Orive-Miguel
David Orive-Miguel
JVJoshua D. Veesa
Joshua D. Veesa
STSusanna Tagliabue
Susanna Tagliabue
APAntonio Pifferi
Antonio Pifferi
Diffuse optics (DO) encompasses a range of photonics tools based on the study of random photon migration in highly scattering media—biological tissues in particular. Due to its unique features, DO is emerging as a powerful means for clinical or homecare diagnostics.1 The basic physics of DO is related to the detection of temporal or spatial alteration in photon distribution re-emitted on the tissue surface.2 Due to the low power (typically few mW) of injected near-infrared light (600- to 1100-nm range), DO is inherently noninvasive. The photon temporal (or spatial) distribution carries information on the absorption—ultimately related to tissue chemical composition, such as water, lipid, collagen content, oxy- and deoxy-hemoglobin concentration, cytochrome c-oxidase3—and scattering properties—linked to tissue microstructure. Further, DO is one of the few noninvasive modalities capable of providing functional information, e.g., brain or muscle activation.4 It can be operated noncontact through remote light illumination and collection.5 It explores the tissue well below the skin at depths of up to 2 to 4 cm. It can provide quantitative operator-independent assessment of the tissue status, such as hemoglobin oxygenation level in the brain. Finally, it is highly scalable, sharing the same technology from large clinical tomographic systems down to wearable devices or homecare appliances.6 For all these aspects, DO is attracting more and more interest in many fields, such as monitoring vital signs like brain oxygenation in critical care or during interventions,7 tumor diagnostics as for breast cancer,8 investigating the impact of lifestyle and nutrition on our body,9 or other fields such as neuroscience and psychology,10 sports, and leisure.11 Even further, the operator independence, the depth sensitivity, and the scalability in addition to noninvasiveness make this option attractive for telemedicine and homecare of patients remotely.

12 October 2022 in Biomedical Optics Express
Verified
Journal Article
Closed access
SSSaeed Samaei
Saeed Samaei
KNKlaudia Nowacka
Klaudia Nowacka
AGAnna Gerega
Anna Gerega
ŻPŻanna Pastuszak
Żanna Pastuszak
Dawid BoryckiDawid Borycki
Dawid Borycki
Interferometric near-infrared spectroscopy (iNIRS) is an optical method that noninvasively measures the optical and dynamic properties of the human brain in vivo. However, the original iNIRS technique uses single-mode fibers for light collection, which reduces the detected light throughput. The reduced light throughput is compensated by the relatively long measurement or integration times (∼1 sec), which preclude monitoring of rapid blood flow changes that could be linked to neural activation. Here, we propose parallel interferometric near-infrared spectroscopy (πNIRS) to overcome this limitation. In πNIRS we use multi-mode fibers for light collection and a high-speed, two-dimensional camera for light detection. Each camera pixel acts effectively as a single iNIRS channel. So, the processed signals from each pixel are spatially averaged to reduce the overall integration time. Moreover, interferometric detection provides us with the unique capability of accessing complex information (amplitude and phase) about the light remitted from the sample, which with more than 8000 parallel channels, enabled us to sense the cerebral blood flow with only a 10 msec integration time (∼100x faster than conventional iNIRS). In this report, we have described the theoretical foundations and possible ways to implement πNIRS. Then, we developed a prototype continuous wave (CW) πNIRS system and validated it in liquid phantoms. We used our CW πNIRS to monitor the pulsatile blood flow in a human forearm in vivo. Finally, we demonstrated that CW πNIRS could monitor activation of the prefrontal cortex by recording the change in blood flow in the forehead of the subject while he was reading an unknown text.

2 August 2021 in Biomedical Optics Express
Verified
Journal Article
Open access
PDF file
SSSaeed Samaei
Saeed Samaei
LCLorenzo Colombo
Lorenzo Colombo
Dawid BoryckiDawid Borycki
Dawid Borycki
MPMarco Pagliazzi
Marco Pagliazzi
TDTurgut Durduran
Turgut Durduran
ALAdam Liebert
Adam Liebert
Time-domain diffuse correlation spectroscopy (TD-DCS) is an emerging optical technique that enables noninvasive measurement of microvascular blood flow with photon path-length resolution. In TD-DCS, a picosecond pulsed laser with a long coherence length, adequate illumination power, and narrow instrument response function (IRF) is required, and satisfying all these features is challenging. To this purpose, in this study we characterized the performance of three different laser sources for TD-DCS. First, the sources were evaluated based on their emission spectrum and IRF. Then, we compared the signal-to-noise ratio and the sensitivity to velocity changes of scattering particles in a series of phantom measurements. We also compared the results for in vivo measurements, performing an arterial occlusion protocol on the forearm of three adult subjects. Overall, each laser has the potential to be successfully used both for laboratory and clinical applications. However, we found that the effects caused by the IRF are more significant than the effect of a limited temporal coherence.

25 August 2025 in Biomedical Optics Express
Verified
Journal Article
Closed access
RERasa Eskandari
Rasa Eskandari
NLNatalie Li
Natalie Li
SSSaeed Samaei
Saeed Samaei
Daniel MilejDaniel Milej
Daniel Milej
KLKeith St. Lawrence
Keith St. Lawrence
MDMamadou Diop
Mamadou Diop
Quantification of cytochrome-c-oxidase (CCO) can directly inform about cerebral metabolic capacity and function, but limited options currently exist for its in vivo assessment. Near-infrared spectroscopy (NIRS) has the potential to quantify CCO and its redox states, but hyperspectral absorption measurements are required due to their broad absorption profiles and low concentrations relative to hemoglobin. While this may be achieved with continuous-wave broadband NIRS (bNIRS), separating the signal contributions of absorption and scattering remains a challenge. Alternatively, time-resolved NIRS (trNIRS) can directly disentangle absorption and scattering but is typically constrained to a few wavelengths. This work aimed to develop an approach for quantifying absolute CCO concentration using discrete-wavelength trNIRS to calibrate bNIRS, yielding calibrated bNIRS (cbNIRS). Monte-Carlo simulations were conducted to validate the algorithm. Subsequently, a hybrid cbNIRS system was assembled, and tissue-mimicking phantoms were prepared with blood, Intralipid, and either yeast or sodium dithionite for validation. The simulations demonstrated that the algorithm can accurately measure absorption across the spectral range (error = 0.8 ± 0.4%). Further, the concentrations of CCO and its different redox states were estimated with an error of 7.9% or less. In the phantom experiments, the measured HbT concentration increased with the addition of blood, but not yeast nor sodium dithionite, and the value agreed with the expected concentration estimated from the packed cell volume of blood. A large increase in total CCO was measured only after the addition of yeast (1.8 ± 0.4 µM). Transitions in the oxygenation state of hemoglobin and redox state of CCO followed the expected trends as the phantom was deoxygenated and reoxygenated. Additionally, the sodium dithionite experiments confirmed that the COO signal measured with cbNIRS is not a result of crosstalk with the hemoglobin signal. This work demonstrates that absolute concentrations of both redox states of CCO can be quantified with high accuracy using cbNIRS. Future work will assess the feasibility of in vivo CCO measurements.

1 July 2020 in APL Photonics
Verified
Journal Article
Open access
PDF file
LCLorenzo Colombo
Lorenzo Colombo
SSSaeed Samaei
Saeed Samaei
PLPranav Lanka
Pranav Lanka
DADaniele Ancora
Daniele Ancora
MPMarco Pagliazzi
Marco Pagliazzi
APAntonio Pifferi
Antonio Pifferi
Near infrared light pulses, multiply scattered by random media, carry useful information regarding the sample key constituents and their microstructures. Usually, the photon diffusion equation is used to interpret the data, which neglects any interference effect in the detected light fields. However, in several experimental techniques, such as diffuse correlation spectroscopy or laser speckle flowmetry, the effect of light coherence is exploited to retrieve the information on the sample dynamical properties. Here, using an actively mode-locked Ti:Sapphire laser, we report the observation of temporal fluctuations in the diffused light pulse, which cannot be described by the diffusion theory. We demonstrate the sensitivity of these fluctuations on the sample dynamical properties and on the number of detected coherence areas (i.e., speckles). In addition, after interpreting the effect as a time-resolved speckle pattern, we propose a simple statistical method for its quantification. The proposed approach may enable the simultaneous monitoring of the static (absorption and scattering coefficients) and dynamical (Brownian diffusion coefficient) properties of the sample, and also provide physical insight on the propagation of optical waves in random media.

1 October 2024 in Neurophotonics
Verified
Journal Article
Open access
PDF file
LSLeena N. Shoemaker
Leena N. Shoemaker
SSSaeed Samaei
Saeed Samaei
GDGraham Deller
Graham Deller
DWDanny J. J. Wang
Danny J. J. Wang
Daniel MilejDaniel Milej
Daniel Milej
KLKeith St. Lawrence
Keith St. Lawrence
Worldwide, acquired brain injuries—ischemic stroke, severe traumatic brain injury, and subarachnoid hemorrhage—are major killers and extremely resource-demanding in terms of direct healthcare costs and long-term disability.1 Intensive care of patients with life-threatening acquired brain injuries not only saves lives but improves neurological outcomes. A primary focus is preventing delayed cerebral ischemia by treating complications that can impede oxygen delivery to the brain, such as systemic hypotension and elevated intracranial pressure.2 Clinical features related to neurological deficits (e.g., paresis) are used to detect worsening neurological status, but these often manifest after ischemic injury has occurred and are not reliable indicators in patients requiring sedation. Studies using invasive probes capable of quantifying cerebral blood flow (CBF), such as thermal diffusion flowmetry, suggested that CBF monitoring improves outcomes by alerting the intensivist team when CBF falls below ischemic thresholds.3 The invasiveness of such probes has hindered greater adoption and speaks to the need to develop non-invasive alternatives.