Yue Xu

Yue Xu

Auto-generated profile, based on publicly available information

Yue Xu

Center for Electromechanics, University of Texas at Austin, Austin, TX 78758, USA

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 May 2020 in IEEE Journal of Emerging and Selected Topics in Power Electronics
Verified
Journal Article
Closed access
SMSlavko Mocevic
Slavko Mocevic
JYJianghui Yu
Jianghui Yu
YXYue Xu
Yue Xu
JSJoshua Stewart
Joshua Stewart
JWJun Wang
Jun Wang
DBDushan Boroyevich
Dushan Boroyevich
While 10kV silicon-carbide (SiC) MOSFETs are gradually penetrating into medium-voltage (MV) applications, intertwined challenges concerning high-voltage insulation, high dv=dt, protections, and thermal management are simultaneously imposed to MV converters. For the modular multilevel converter, a systematical power-cell design and assessment methodology (DAM) to tackle the unprecedented challenge synergy is essential, and yet, absent. Thereby, this paper aims to develop DAM based on a high-current 10kV SiC MOSFET half-bridge module. An overall introduction of the power cell and a hierarchical DAM workflow is first presented, followed by the comprehensive component-level DAM with details in design challenges, solutions, assessment instruments, procedures, and test results. Subsequently, the DAM is expanded to the power-cell level by exploring its safe operating area associated with switching frequency, power-processing capability, and temperature limit in various operation modes, which in turn, validates the component designs and determines if they need iterations. Following the methodology, the power-cell design is finalized, capable of continuous operation under 6kV, 84A rms, and 10kHz, exhibiting 99.3% efficiency and transient immunity up to 100V=ns.

22 July 2020 in IEEE Journal of Emerging and Selected Topics in Power Electronics
Verified
Journal Article
Closed access
KSKeyao Sun
Keyao Sun
YXYue Xu
Yue Xu
JWJun Wang
Jun Wang
RBRolando Burgos
Rolando Burgos
DBDushan Boroyevich
Dushan Boroyevich
Auxiliary power supply (APS) that provides reliable power and voltage for gate drivers, controllers, and sensors is a critical component in medium voltage (MV) converter. Compared to being fed from the power-cell dc-link, APS fed from an external earthed system has its own benefits. However, with the power-cell number scaled up, the insulation design of the externally-fed APS becomes a significant challenge. Partial discharge (PD) can cause accumulative irreversible damages of insulation, which further lead to auxiliary power circuit fault and eventually cascaded failures of the whole converter system. Therefore, a PD-free APS system ensuring the reliability of MV converter is required. Among different technologies for building APS, wireless power transfer (WPT) becomes an attractive method because of its mechanical design flexibility and inborn insulation capability. In this paper, in order to design a PD-free WPT converter, insulation design criterion and electric field distribution under different coil geometries are analyzed, compared, and tested. Subsequently, a comprehensive insulation design including the influence of ferrite shielding layer is shown. Finally, an optimized WPT prototype with 120 W output power, 92.78% full-power efficiency, 2.76pF isolation capacitance, and 27 kV insulation capability is validated experimentally.

12 September 2022 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
ZGZhicheng Guo
Zhicheng Guo
SRSanjay Rajendran
Sanjay Rajendran
JTJagadeesh Tangudu
Jagadeesh Tangudu
YKYasmin Khakpour
Yasmin Khakpour
STStephen Taylor
Stephen Taylor
AHAlex Q. Huang
Alex Q. Huang
High voltage insulation and thermal management are the two major challenges in a high-power medium frequency transformer (MFT) design. This letter proposes novel insulation and cooling structure with potted windings in a 100 kW MFT with two FINEMET FT-3TL magnetic cores and parallel-concentric winding structure. For the first time, a three-dimensional printed bobbin with heatsink fins is demonstrated. The 100 kW MFT achieves a power density of 10.6 kW/L and a partial discharge inception voltage of 20 kV peak. The MFT is applied in a dual active bridge based medium voltage solid state transformer, achieving a peak efficiency of 98.2% at 40 kW and 97.5% at 100 kW. The MFT itself has a 99.735% efficiency with superior thermal performance at 100 kW output power.

12 June 2019 in IEEE Journal of Emerging and Selected Topics in Power Electronics
Verified
Journal Article
Closed access
YXYue Xu
Yue Xu
XFXianyong Feng
Xianyong Feng
JWJun Wang
Jun Wang
CGchaofei gao
chaofei gao
RBRolando Burgos
Rolando Burgos
Robert HebnerRobert Hebner
Robert Hebner
Laminated bus has been widely used in power converters for decades. Thicker insulation increases parasitic inductance, weight and size of the bus and decreases cooling performance and power density. Thus, it is desired to have thinner insulation while achieving the desired lifetime. The emerging medium voltage (MV) SiC-based converters require fast switching transients and high power density, which makes the optimal laminated bus design challenging. Since the internal partial discharges (PD) can significantly degrade insulation, they should be eliminated in the design stage to ensure the optimal performance. However, insulation overdesign does not necessarily help remove PD from internal defects and air pockets in the laminated bus. In order to obtain a PD-free laminated bus with thin insulation, this paper uses representative structures to show a path for removing internal PDs. This paper presents a systematic approach to remove air pockets and reduce the impact of the unavoidable defects in adhesive layers through theoretical and experimental studies. In addition, a proper material selection and processing method is derived to reduce the size and number of internal defects, while lead to a more favorable electric field distribution. The PD experimental results suggest the effectiveness of the proposed approach.

11 April 2019 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
CGchaofei gao
chaofei gao
YXYue Xu
Yue Xu
JWJun Wang
Jun Wang
RBRolando Burgos
Rolando Burgos
DBDushan Boroyevich
Dushan Boroyevich
WWWei Wang
Wei Wang
As a consequence of higher blocking voltage and power density by using SiC devices, detailed analysis and careful design of insulation are important for future medium-voltage power converters. Because of the insulation or mechanical coordination, air gaps inside the converters cannot be avoided. Moreover, some gaps are more critical than others, since much oversized design or electric shielding there cannot be acceptable. Admittedly, the final design should be partial discharge (PD) free under normal operation with a safety margin. However, due to possible change of air properties and insulation degradation, massive PD can be still initiated from high electric field regions along the gaps and may lead to the damage of devices, through the highly coupled power and driving circuitry. Therefore, with online PD monitoring and localization, insulation health condition of the critical gaps can be provided, which could have great values for converter operation, maintenance, and design. In this paper, after detailed acoustic signal propagation study, a fiber-optic acoustic sensor array has been implemented into a 6-kV H-bridge power electronics building block prototype, in order to realize online PD monitoring along the critical gaps. Finally, from experimental results, the proposed sensor array has good sensitivity, localization accuracy, and high immunity to the electromagnetic interference. It unveils a novel access to insulation online monitoring for future high voltage, high power density SiC-device-based converters.

21 May 2020 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
CZChongxing Zhang
Chongxing Zhang
YXYue Xu
Yue Xu
MDMing Dong
Ming Dong
RBRolando Burgos
Rolando Burgos
MRMing Ren
Ming Ren
DBDushan Boroyevich
Dushan Boroyevich
Exposed metal or insulator to air interfaces are widely existing in medium voltage SiC based converters. To address external insulation along such interfaces properly, large insulation distance in air is applied. However, such insulation tends to significantly impair converter power densities and performances. Targeting on the external discharge free design, design suggestions which can reflect the relationship between insulation structures and square wave excitation parameters, are highly demanded. Moreover, due to possible fabrication issues and insulation degradation, massive external discharges may still occur, even that they should be eliminated by design. Therefore, insulation assessment along the entire system, or at least for critical components, is necessary. In this paper, silicon photomultiplier (SiPM) based external discharge detection solutions are introduced. Then, for a self-designed SiC based medium voltage converter, SiPM sensors help both its external insulation design and assessment. By using SiPM sensors, two types of external discharges are characterized under square wave excitation and thus general design suggestions are developed. Moreover, as shown by two examples, SiPM sensors can be used to assess the external insulation for converter applications.