Korbinian Eckstein

Korbinian Eckstein

Auto-generated profile, based on publicly available information

Korbinian Eckstein

University of Queensland, Brisbane, Australia

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 October 2020 in Magnetic Resonance in Medicine
Verified
Journal Article
Open access
PDF file
BDBarbara Dymerska
Barbara Dymerska
KEKorbinian Eckstein
Korbinian Eckstein
BBBeata Bachrata
Beata Bachrata
BSBernard Siow
Bernard Siow
Siegfried TrattnigSiegfried Trattnig
Siegfried Trattnig
SRSimon Daniel Robinson
Simon Daniel Robinson
Purpose: To develop a rapid and accurate MRI phase‐unwrapping technique for challenging phase topographies encountered at high magnetic fields, around metal implants, or postoperative cavities, which is sufficiently fast to be applied to large‐group studies including Quantitative Susceptibility Mapping and functional MRI (with phase‐based distortion correction).Methods: The proposed path‐following phase‐unwrapping algorithm, ROMEO, estimates the coherence of the signal both in space—using MRI magnitude and phase information—and over time, assuming approximately linear temporal phase evolution. This information is combined to form a quality map that guides the unwrapping along a 3D path through the object using a computationally efficient minimum spanning tree algorithm. ROMEO was tested against the two most commonly used exact phase‐unwrapping methods, PRELUDE and BEST PATH, in simulated topographies and at several field strengths: in 3T and 7T in vivo human head images and 9.4T ex vivo rat head images.Results: ROMEO was more reliable than PRELUDE and BEST PATH, yielding unwrapping results with excellent temporal stability for multi‐echo or multi‐time‐point data. It does not require image masking and delivers results within seconds, even in large, highly wrapped multi‐echo data sets (eg, 9 seconds for a 7T head data set with 31 echoes and a 208 × 208 × 96 matrix size).Conclusion: Overall, ROMEO was both faster and more accurate than PRELUDE and BEST PATH, delivering exact results within seconds, which is well below typical image acquisition times, enabling potential on‐console application.

8 January 2024 in Nature Methods
Verified
Journal Article
Closed access
PDF file
ARAngela I. Renton
Angela I. Renton
TDThuy T. Dao
Thuy T. Dao
TJTom Johnstone
Tom Johnstone
OCOren Civier
Oren Civier
RSRyan P. Sullivan
Ryan P. Sullivan
SBSteffen Bollmann
Steffen Bollmann

27 June 2025 in Journal of Open Source Software
Verified
Journal Article
Open access
PDF file
TTTim M. Tierney
Tim M. Tierney
NANicholas A. Alexander
Nicholas A. Alexander
JAJohn Ashburner
John Ashburner
NANicole Labra Avila
Nicole Labra Avila
YBYaël Balbastre
Yaël Balbastre
PZPeter Zeidman
Peter Zeidman
Statistical Parametric Mapping (SPM) is an integrated set of methods for testing hypotheses about the brain's structure and function, using data from imaging devices. These methods are implemented in an open source software package, SPM, which has been in continuous development for more than 30 years by an international community of developers. This paper reports the release of SPM 25.01, a major new version of the software that incorporates novel analysis methods, optimisations of existing methods, as well as improved practices for open science and software development.

26 June 2022 in Magnetic Resonance in Medicine
Verified
Journal Article
Open access
GHGisela E Hagberg
Gisela E Hagberg
KEKorbinian Eckstein
Korbinian Eckstein
ETElisa Tuzzi
Elisa Tuzzi
JZJiazheng Zhou
Jiazheng Zhou
SRSimon Robinson
Simon Robinson
KSKlaus Scheffler
Klaus Scheffler
Purpose: To develop improved tissue masks for QSM.Methods: Masks including voxels at the brain surface were automatically generated from the magnitude alone (MM) or combined with test functions from the first (PG) or second (PB) derivative of the sign of the wrapped phase.Phase images at 3T and 9.4T were simulated at different TEs and used to generate a mask, PItoh, with between‐voxel phase differences less than π. MM, PG, and PB were compared with PItoh. QSM were generated from 3D multi‐echo gradient‐echo data acquired at 9.4T (21 subjects aged: 20‐56y), and from the QSM2016 challenge 3T data using different masks, unwrapping, background removal, and dipole inversion algorithms. QSM contrast was quantified using age‐based iron concentrations.Results: Close to air cavities, phase wraps became denser with increasing field and echo time, yielding increased values of the test functions. Compared with PItoh, PB had the highest Dice coefficient, while PG had the lowest and MM the highest percentage of voxels outside PItoh.Artifacts observed in QSM at 9.4T with MM were mitigated by stronger background filters but yielded a reduced QSM contrast. With PB, QSM contrast was greater and artifacts diminished. Similar results were obtained with challenge data, evidencing larger effects of mask close to air cavities.Conclusion: Automatic, phase‐based masking founded on the second derivative of the sign of the wrapped phase, including cortical voxels at the brain surface, was able to mitigate artifacts and restore QSM contrast across cortical and subcortical brain regions.

7 August 2023 in Human Brain Mapping
Verified
Journal Article
Open access
SRSimon Daniel Robinson
Simon Daniel Robinson
BBBeata Bachrata
Beata Bachrata
KEKorbinian Eckstein
Korbinian Eckstein
SBSaskia Bollmann
Saskia Bollmann
SBSteffen Bollmann
Steffen Bollmann
MBMarkus Barth
Markus Barth
The boundaries between tissues with different magnetic susceptibilities generate inhomogeneities in the main magnetic field which change over time due to motion, respiration and system instabilities. The dynamically changing field can be measured from the phase of the fMRI data and corrected. However, methods for doing so need multi‐echo data, time‐consuming reference scans and/or involve error‐prone processing steps, such as phase unwrapping, which are difficult to implement robustly on the MRI host. The improved dynamic distortion correction method we propose is based on the phase of the single‐echo EPI data acquired for fMRI, phase offsets calculated from a triple‐echo, bipolar reference scan of circa 3–10 s duration using a method which avoids the need for phase unwrapping and an additional correction derived from one EPI volume in which the readout direction is reversed. This Reverse‐Encoded First Image and Low resoLution reference scan (REFILL) approach is shown to accurately measure B 0 as it changes due to shim, motion and respiration, even with large dynamic changes to the field at 7 T, where it led to a > 20% increase in time‐series signal to noise ratio compared to data corrected with the classic static approach. fMRI results from REFILL‐corrected data were free of stimulus‐correlated distortion artefacts seen when data were corrected with static field mapping. The method is insensitive to shim changes and eddy current differences between the reference scan and the fMRI time series, and employs calculation steps that are simple and robust, allowing most data processing to be performed in real time on the scanner image reconstruction computer. These improvements make it feasible to routinely perform dynamic distortion correction in fMRI.

8 January 2025 in NeuroImage
Verified
Journal Article
Open access
LHLukas Hingerl
Lukas Hingerl
BSBernhard Strasser
Bernhard Strasser
SSSimon Schmidt
Simon Schmidt
KEKorbinian Eckstein
Korbinian Eckstein
GGGuglielmo Genovese
Guglielmo Genovese
MMMałgorzata Marjańska
Małgorzata Marjańska
Ultra-high-field magnetic resonance (MR) systems (7 T and 9.4 T) offer the ability to probe human brain metabolism with enhanced precision. Here, we present the preliminary findings from 3D MR spectroscopic imaging (MRSI) of the human brain conducted with the world's first 10.5 T whole-body MR system. Employing a custom-built 16-channel transmit and 80-channel receive MR coil at 10.5 T, we conducted MRSI acquisitions in six healthy volunteers to map metabolic compounds in the human cerebrum in vivo. Three MRSI protocols with different matrix sizes and scan times (4.4 × 4.4 × 4.4 mm³: 10 min, 3.4 × 3.4 × 3.4 mm³: 15 min, and 2.75×2.75×2.75 mm³: 25 min) were tested. Concentric ring trajectories were utilized for time-efficient encoding of a spherical 3D k-space with ∼4 kHz spectral bandwidth. B0/B1 shimming was performed based on respective field mapping sequences and anatomical T1-weighted MRI were obtained. By combining the benefits of an ultra-high-field system with the advantages of free-induction-decay (FID-)MRSI, we present the first metabolic maps acquired at 10.5 T in the healthy human brain at both high (voxel size of 4.4³ mm³) and ultra-high (voxel size of 2.75³ mm³) isotropic spatial resolutions. Maps of 13 metabolic compounds (aspartate, choline compounds and creatine + phosphocreatine, γ-aminobutyric acid (GABA), glucose, glutamine, glutamate, glutathione, myo-inositol, scyllo-inositol, N-acetylaspartate (NAA), N-acetylaspartylglutamate (NAAG), taurine) and macromolecules were obtained individually. The spectral quality was outstanding in the parietal and occipital lobes, but lower in other brain regions such as the temporal and frontal lobes. The average total NAA (tNAA = NAA + NAAG) signal-to-noise ratio over the whole volume of interest was 12.1± 8.9 and the full width at half maximum of tNAA was 24.7± 9.6 Hz for the 2.75 × 2.75 × 2.75 mm³ resolution. The need for an increased spectral bandwidth in combination with spatio-spectral encoding imposed significant challenges on the gradient system, but the FID approach proved very robust to field inhomogeneities of ∆B0 = 45 ± 38 Hz (frequency offset ± spatial STD) and B1+ = 65 ± 11° within the MRSI volume of interest. These preliminary findings highlight the potential of 10.5 T MRSI as a powerful imaging tool for probing cerebral metabolism. By providing unprecedented spatial and spectral resolution, this technology could offer a unique view into the metabolic intricacies of the human brain, but further technical developments will be necessary to optimize data quality and fully leverage the capabilities of 10.5 T MRSI.