Simon Schmidt

Simon Schmidt

Auto-generated profile, based on publicly available information

Simon Schmidt

Center for Magnetic Resonance Research (CMRR) University of Minnesota Minneapolis Minnesota USA

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 December 2020 in Magnetic Resonance in Medicine
Verified
Journal Article
Open access
PDF file
SDSebastian Dietrich
Sebastian Dietrich
CAChristoph S. Aigner
Christoph S. Aigner
CKChristoph Kolbitsch
Christoph Kolbitsch
JMJohannes Mayer
Johannes Mayer
JLJuliane Ludwig
Juliane Ludwig
SSSebastian Schmitter
Sebastian Schmitter
Purpose: To introduce and investigate a method for free‐breathing three‐dimensional (3D) mapping of the human body at ultrahigh field (UHF), which can be used to generate homogenous flip angle (FA) distributions in the human body at UHF.Methods: A 3D relative mapping sequence with a radial phase‐encoding (RPE) k‐space trajectory was developed and applied in 11 healthy subjects at 7T. An RPE‐based actual flip angle mapping method was applied with a dedicated shim setting to calibrate the relative maps yielding absolute maps of the individual transmit channels. The method was evaluated in a motion phantom and by multidimensional in vivo measurements. Additionally, 3D gradient echo scans with and without static phase‐only shims were used to qualitatively validate shim predictions.Results: The phantom validation revealed good agreement for maps between dynamic measurement and static reference acquisition. The proposed 3D method was successfully validated in vivo by comparing magnitude and phase distributions with a 2D Cartesian reference. 3D maps free from visible motion artifacts were successfully acquired for 11 subjects with body mass indexes ranging from 19 kg/m2 to 34 kg/m2. 3D respiration‐resolved absolute maps indicated FA differences between inhalation and exhalation up to 15% for one channel and up to 24% for combined channels for shallow breathing.Conclusion: The proposed method provides respiration‐resolved absolute 3D maps of the human body at UHF, which enables the investigation and development of 3D shimming and parallel transmission methods to further enhance body imaging at UHF.

13 March 2025 in Magnetic Resonance in Medicine
Verified
Journal Article
Open access
RLRussell L. Lagore
Russell L. Lagore
ASAlireza Sadeghi-Tarakameh
Alireza Sadeghi-Tarakameh
AGAndrea Grant
Andrea Grant
MWMatt Waks
Matt Waks
EAEdward Auerbach
Edward Auerbach
KUKamil Uğurbil
Kamil Uğurbil
Purpose: To develop and characterize a 128‐channel head array for brain imaging at 10.5 T, evaluate signal‐to‐noise ratio (SNR) relative to ultimate intrinsic SNR (uiSNR) and lower field strengths, and demonstrate human brain anatomical and functional imaging with this unique magnetic field and high‐channel‐count array. Methods: The coil consists of a 16‐channel self‐decoupled loop transmit/receive (16Tx/Rx) array with a 112‐loop receive‐only (Rx) insert. Interactions between the 16Tx/Rx array and the 112Rx insert were mitigated using coaxial cable traps placed every 1/16 of a wavelength on each feed cable, locating most preamplifier boards outside the transmitter field, and miniaturizing those placed directly on individual coils. Results: The effect of the 112Rx insert on the circumscribing 16Tx/Rx array was minimized, leading to similar transmit field maps obtained experimentally with and without the 112Rx array in place and by electromagnetic simulations of the 16Tx/Rx array alone. The 128‐channel array captured 77% of uiSNR centrally. Significantly higher 1/g‐factor values across the whole brain was achieved compared with 7 T. Excellent SNR, high parallel‐imaging performance, and minimal Tx‐Rx interactions collectively facilitated acquisition of high‐quality, high‐resolution, proof‐of‐concept functional and anatomical images, including with power‐demanding sequences in the human brain. Conclusions: Counterintuitive to expectations based on magnetic fields less than or equal to 7 T, the higher channel counts provided SNR gains centrally, capturing about 80% uiSNR. The fraction of uiSNR achieved centrally in 64Rx, 80Rx, and 128Rx arrays suggested that a plateau was being reached at 80%. At this plateau, B 0 ‐dependent SNR gains for 10.5 T relative to 7 T were approximately linear to quadratic for the periphery and the center, respectively.

16 October 2024 in Magnetic Resonance in Medicine
Verified
Journal Article
Open access
MWMatt Waks
Matt Waks
RLRussell L. Lagore
Russell L. Lagore
EAEdward Auerbach
Edward Auerbach
AGAndrea Grant
Andrea Grant
ASAlireza Sadeghi-Tarakameh
Alireza Sadeghi-Tarakameh
KUKamil Uğurbil
Kamil Uğurbil
Purpose: Toward pushing the boundaries of ultrahigh fields for human brain imaging, we wish to evaluate experimentally achievable SNR relative to ultimate intrinsic SNR (uiSNR) at 10.5T, develop design strategies toward approaching the latter, quantify magnetic field–dependent SNR gains, and demonstrate the feasibility of whole‐brain, high‐resolution human brain imaging at this uniquely high field strength.Methods: A dual row 16‐channel self‐decoupled transmit (Tx) and receive (Rx) array was developed for 10.5T using custom Tx/Rx switches. A 64‐channel receive‐only array was built to fit into the 16‐channel Tx/Rx array. Electromagnetic modeling and experiments were used to define safe operational power limits. Experimental SNR was evaluated relative to uiSNR at 10.5T and 7T.Results: The 64‐channel Rx array alone captured approximately 50% of the central uiSNR at 10.5T, while an identical array developed for 7T captured about 76% of uiSNR at 7T. The 16‐channel Tx/80‐channel Rx configuration brought the fraction of uiSNR captured at 10.5T to levels comparable to the 64‐channel Rx array at 7T. SNR data displayed an approximate dependence over a large central region when evaluated in the context of uiSNR. Whole‐brain, high‐resolution ‐weighted and T1‐weighted anatomical and gradient‐recalled‐echo BOLD‐EPI functional MRI images were obtained at 10.5T for the first time with such an advanced array.Conclusion: We demonstrated the ability to approach the uiSNR at 10.5T over the human brain, achieving large SNR gains over 7T, currently the most commonly used ultrahigh‐field platform. Whole‐brain, high‐resolution anatomical and EPI‐based functional MRI data were obtained at 10.5T, illustrating the promise of greater than 10T fields in studying the human brain.

17 October 2018 in Journal of Magnetic Resonance Imaging
Verified
Journal Article
Closed access
PDF file
JEJulian Emmerich
Julian Emmerich
SFSebastian Flassbeck
Sebastian Flassbeck
SSSimon Schmidt
Simon Schmidt
PBPeter Bachert
Peter Bachert
MLMark E. Ladd
Mark E. Ladd
SSSina Straub
Sina Straub

2 December 2018 in Magnetic Resonance in Medicine
Verified
Journal Article
Closed access
PDF file
SFSebastian Flassbeck
Sebastian Flassbeck
SSSimon Schmidt
Simon Schmidt
PBPeter Bachert
Peter Bachert
MLMark E. Ladd
Mark E. Ladd
SSSebastian Schmitter
Sebastian Schmitter

9 January 2021 in Magnetic Resonance in Medicine
Verified
Journal Article
Open access
PDF file
SSSimon Schmidt
Simon Schmidt
SFSebastian Flassbeck
Sebastian Flassbeck
SSSonja Schmelter
Sonja Schmelter
ESEllen Schmeyer
Ellen Schmeyer
MLMark E. Ladd
Mark E. Ladd
SSSebastian Schmitter
Sebastian Schmitter
Purpose: To investigate the amplitude and spatial distribution of errors in wall shear stress (WSS) values derived from 4D flow measurements caused by displacement artifacts intrinsic to the 4D flow acquisition.Methods: Phase‐contrast MRI velocimetry was performed in a model of a stenotic aorta using two different timing schemes, both of which are commonly applied in vivo but differ in their resulting displacement artifacts. Whereas one scheme is optimized to minimize the duration of the encoding gradients (herein called FAST), the other aims to specifically minimize displacement artifacts by synchronizing all three spatial‐encoding time points (called ECHO). WSS estimates were calculated and compared to unbiased WSS values obtained by a 5‐hour single‐point imaging acquisition. In addition, MRI simulations based on computational fluid dynamics data were carried out to investigate the impact of gradient timings corresponding to different spatial resolutions.Results: 4D flow displacement artifacts were found to have an impact on the quantified WSS peak values, spatial location, and overall WSS pattern. FAST leads to the underestimation of local WSS values in the phantom arch by up to 90%. Moreover, the corresponding WSS estimates depend on the image orientation. This effect was avoided using ECHO, which, however, results in biased WSS values within the stenosis, yielding an underestimation of peak WSS by up to 17%. Computational fluid dynamics‐based simulation results show that the bias in WSS due to displacement artifacts increases with increasing spatial resolution, thus counteracting the resolution benefit for WSS due to reduced partial volume effects and segmentation errors.Conclusions: 4D flow displacement artifacts can significantly impact the WSS estimates and depend on the timing scheme as well as potentially the image orientation. Whereas FAST might allow correct WSS estimation for lower resolutions, ECHO is recommended especially when spatial resolutions of 1 mm and smaller are used. Users need to be aware of this nonnegligible effect, particularly when conducting inter‐site studies or studies between vendors. The timing scheme should thus be explicitly mentioned in publications.