24 May 2025 in Magnetic Resonance in Medicine
Purpose: To explore the feasibility of CEST imaging in the human liver at 7 T with shimming. Methods: CEST MRI was performed on a 7 T whole‐body scanner with a parallel transmission (pTx) system in five healthy volunteers. Static pTx ( shimming) was applied to locally maximize the magnitude per input power within a given region of interest (ROI) of approximately 30 mm diameter (ROI shim ). Relaxation‐compensated inverse magnetization transfer ratio (MTR Rex ) values were quantified for amide protons, guanidino protons, and relayed nuclear Overhauser effect signals based on five‐pool Lorentzian fit analysis. MTR Rex values were corrected for B 1 inhomogeneities using an absolute, accurate MR fingerprinting–based mapping technique. Results: Within the ROI shim , reliable MTR Rex values could be calculated for an average of 85% of voxels. The mean MTR Rex values and corresponding coefficient of variations across the group are: 0.113 ± 0.009, 8.8% for amide; 0.167 ± 0.010, 6.3% for nuclear Overhauser effect; and 0.079 ± 0.010, 12.9% for guanidino. MTR Rex values exhibit low variation between subjects, as reflected by low coefficient of variations. Conclusion: In this study, we have demonstrated for the first time the feasibility of acquiring and quantifying relaxation‐compensated CEST contrasts in the human liver at ultrahigh field. The application of static pTx effectively eliminates dropouts and allows for accurate CEST contrast quantification within the selected ROI. In addition, the proposed mapping technique shows efficacy for enhanced MTR Rex B 1 corrections in the abdomen.
3 January 2026 in Magnetic Resonance Materials in Physics, Biology and Medicine
Objective: To quantify the T 1 relaxation times at 7T for key abdominal organs and tissues, including the liver, kidney, spleen, and skeletal paraspinal muscles. Materials and methods: T 1 mapping was performed on a 7T whole-body scanner with a parallel transmission (pTx) system in five healthy volunteers. Static pTx (B 1 + shimming) was applied to maximize B 1 + magnitude in the target region. For each T 1 map, data were collected using eight snapshot gradient-echo inversion recovery sequences during breath holding. Voxel-wise T 1 values were calculated based on DICOM data using exponential model fitting. Results: Mean abdomen T 1 values and corresponding coefficients of variation across the group were: 1829 ± 60 ms, 3.3% for the kidney cortex; 2619 ± 83 ms, 3.2% for the kidney medulla; 1378 ± 48 ms, 3.5% for the liver; 1954 ± 28 ms, 1.4% for the skeletal paraspinal muscle; 1770 ± 36 ms, 2.0% for the spleen. Conclusion: In this study, we quantified the T 1 relaxation times at 7T for key abdominal organs and tissues, including the liver, kidney, spleen, and skeletal paraspinal muscle. To achieve this, pTx was applied to mitigate B 1 + dropouts in the target regions. The B 1 + insensitive snapshot gradient-echo inversion recovery method was utilized to acquire accurate and reproducible T 1 maps.