12 August 2024 in Magnetic Resonance in Medicine
CGConstance G. F. Gatefait
+4
Purpose: This study aims to map the transmit magnetic field () in the human body at 7T using MR fingerprinting (MRF), with a focus on achieving high accuracy and precision across a large dynamic range, particularly at low flip angles (FAs).Methods: A FLASH‐based MRF sequence (B1‐MRF) with high sensitivity was developed. Phantom and in vivo abdominal imaging were performed at 7T, and the results were compared with established reference methods, including a slow but precise preparation‐based method (PEX), saturated TurboFLASH (satTFL), actual flip angle imaging (AFI) and Bloch‐Siegert shift (BSS).Results: The MRF signal curve was highly sensitive to , while T1 sensitivity was comparatively low. The phantom experiment showed good agreement of to PEX for a T1 range of 204–1691 ms evaluated at FAs from 0° to 70°. Compared to the references, a dynamic range increase larger than a factor of two was determined experimentally. In vivo liver scans showed a strong correlation between B1‐MRF, satTFL, and RPE‐AFI in a low body mass index (BMI) subject (18.1 kg/m2). However, in larger BMI subjects (≥25.5 kg/m2), inconsistencies were observed in low regions for satTFL and RPE‐AFI, while B1‐MRF still provided consistent results in these regions.Conclusion: B1‐MRF provides accurate and precise maps over a wide range of FAs, surpassing the capabilities of existing methods in the FA range < 60°. Its enhanced sensitivity at low FAs is advantageous for various applications requiring precise estimates, potentially advancing the frontiers of ultra‐high field (UHF) body imaging at 7T and beyond.
5 March 2024 in Magnetic Resonance in Medicine
Purpose: To research and evaluate the performance of broadband tailored kT‐point pulses (TP) and universal pulses (UP) for homogeneous excitation of the human heart at 7T.Methods: Relative 3D ‐maps of the thorax were acquired from 29 healthy volunteers. TP and UP were designed using the small‐tip‐angle approximation for a different composition of up to seven resonance frequencies. TP were computed for each of the 29 ‐maps, and UPs were calculated using 22 ‐maps and tested in seven testcases. The performance of the pulses was analyzed using the coefficient of variation (CV) in the 3D heart volumes. The 3D gradient‐echo (GRE) scans were acquired for the seven testcases to qualitatively validate the ‐predictions.Results: Single‐ and double‐frequency optimized pulses achieved homogeneity in flip angle (FA) for the frequencies they were optimized for, while the broadband pulses achieved uniformity in FA across a 1300 Hz frequency range.Conclusion: Broadband TP and UP can be used for homogeneous excitation of the heart volume across a 1300 Hz frequency range, including the water and the main six fat peaks, or with longer pulse durations and higher FAs for a smaller transmit bandwidth. Moreover, despite large inter‐volunteer variations, broadband UP can be used for calibration‐free 3D heart FA homogenization in time‐critical situations.
18 June 2025 in NMR in Biomedicine
This work proposes a 3D multi‐transmit channel B1+ mapping approach based on magnetic resonance fingerprinting (MRF) for the human abdomen at 7 T. A stack‐of‐stars acquisition is employed to achieve motion‐robust 3D encoding, along with a hybrid method where transmit (Tx) channel‐wise B1+ information is obtained through low flip angle GRE images. B1+ mapping at ultra‐high field (UHF) in the human abdomen is particularly challenging due to the large dynamic range of B1+, the extensive field of view (FOV), and the effects of respiratory motion. Few methods have been proposed to address these challenges, with a significant limitation being the relatively low RF power available at UHF, especially for pTx systems with a 8 × 1 kW power configuration. This limitation makes it difficult to achieve FAs greater than 30° in central body regions, which are required for accurate results with classical methods. In contrast, Tx channel‐combined MRF‐based B1+ mapping has been validated as accurate for FAs greater than 6°, offering improved accuracy at low FAs. Here, two Tx channel‐combined MRF‐based B1+ maps (B1‐MRF) are acquired using two tailored complementary phase shims to obtain absolute B1+ information across the entire FOV. The 3D hybrid approach was validated against a 2D reference using phantoms and in vivo free‐breathing scans in three subjects with varying BMIs, where only one Tx channel was active at a time. The comparison showed strong agreement, with the 3D hybrid acquisition demonstrating improved performance in regions affected by flow, low FAs, or low signal‐to‐noise ratio compared to the 2D implementation. The higher accuracy and level of detail provided by the proposed method, in contrast to existing methods, are particularly relevant for several applications, including the validation of faster approaches, validation of electromagnetic simulations (which are safety‐critical), and the creation of B1+ map libraries for applications such as AI‐based B1+ mapping or universal pulse calculations.
27 October 2024 in Magnetic Resonance in Medicine
Purpose: This study investigates the feasibility of using complex‐valued neural networks (NNs) to estimate quantitative transmit magnetic RF field (B 1 + ) maps from multi‐slice localizer scans with different slice orientations in the human head at 7T, aiming to accelerate subject‐specific B 1 + ‐calibration using parallel transmission (pTx). Methods: Datasets containing channel‐wise B 1 + ‐maps and corresponding multi‐slice localizers were acquired in axial, sagittal, and coronal orientation in 15 healthy subjects utilizing an eight‐channel pTx transceiver head coil. Training included five‐fold cross‐validation for four network configurations: used transversal, sagittal, coronal data, and was trained on all slice orientations. The resulting maps were compared to B 1 + ‐reference scans using different quality metrics. The proposed network was applied in‐vivo at 7T in two unseen test subjects using dynamic kt‐point pulses. Results: Predicted B 1 + ‐maps demonstrated a high similarity with measured B 1 + ‐maps across multiple orientations. The estimation matched the reference with a mean relative error in the magnitude of (2.70 ± 2.86)% and mean absolute phase difference of (6.70 ± 1.99)° for transversal, (1.82 ± 0.69)% and (4.25 ± 1.62)° for sagittal (), as well as (1.33 ± 0.27)% and (2.66 ± 0.60)° for coronal slices () considering brain tissue. trained on all orientations enables a robust prediction of B 1 + ‐maps across different orientations. Achieving a homogenous excitation over the whole brain for an in‐vivo application displayed the approach's feasibility. Conclusion: This study demonstrates the feasibility of utilizing complex‐valued NNs to estimate multi‐slice B 1 + ‐maps in different slice orientations from localizer scans in the human brain at 7T.
24 May 2025 in Magnetic Resonance in Medicine
Purpose: To explore the feasibility of CEST imaging in the human liver at 7 T with shimming. Methods: CEST MRI was performed on a 7 T whole‐body scanner with a parallel transmission (pTx) system in five healthy volunteers. Static pTx ( shimming) was applied to locally maximize the magnitude per input power within a given region of interest (ROI) of approximately 30 mm diameter (ROI shim ). Relaxation‐compensated inverse magnetization transfer ratio (MTR Rex ) values were quantified for amide protons, guanidino protons, and relayed nuclear Overhauser effect signals based on five‐pool Lorentzian fit analysis. MTR Rex values were corrected for B 1 inhomogeneities using an absolute, accurate MR fingerprinting–based mapping technique. Results: Within the ROI shim , reliable MTR Rex values could be calculated for an average of 85% of voxels. The mean MTR Rex values and corresponding coefficient of variations across the group are: 0.113 ± 0.009, 8.8% for amide; 0.167 ± 0.010, 6.3% for nuclear Overhauser effect; and 0.079 ± 0.010, 12.9% for guanidino. MTR Rex values exhibit low variation between subjects, as reflected by low coefficient of variations. Conclusion: In this study, we have demonstrated for the first time the feasibility of acquiring and quantifying relaxation‐compensated CEST contrasts in the human liver at ultrahigh field. The application of static pTx effectively eliminates dropouts and allows for accurate CEST contrast quantification within the selected ROI. In addition, the proposed mapping technique shows efficacy for enhanced MTR Rex B 1 corrections in the abdomen.