Daniel Stäb

Daniel Stäb

Auto-generated profile, based on publicly available information

Daniel Stäb

MR Research Collaborations Siemens Healthcare Limited Melbourne Australia

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 October 2020 in Scientific Data
Verified
Journal Article
Open access
PDF file
SJSharna D. Jamadar
Sharna D. Jamadar
PWPhillip G. D. Ward
Phillip G. D. Ward
TCThomas G. Close
Thomas G. Close
AFAlex Fornito
Alex Fornito
MPMalin Premaratne
Malin Premaratne
GEGary F Egan
Gary F Egan
Simultaneous [18 F]-fluorodeoxyglucose positron emission tomography and functional magnetic resonance imaging (FDG-PET/fMRI) provides the capability to image two sources of energetic dynamics in the brain – cerebral glucose uptake and the cerebrovascular haemodynamic response. Resting-state fMRI connectivity has been enormously useful for characterising interactions between distributed brain regions in humans. Metabolic connectivity has recently emerged as a complementary measure to investigate brain network dynamics. Functional PET (fPET) is a new approach for measuring FDG uptake with high temporal resolution and has recently shown promise for assessing the dynamics of neural metabolism. Simultaneous fMRI/fPET is a relatively new hybrid imaging modality, with only a few biomedical imaging research facilities able to acquire FDG PET and BOLD fMRI data simultaneously. We present data for n = 27 healthy young adults (18–20 yrs) who underwent a 95-min simultaneous fMRI/fPET scan while resting with their eyes open. This dataset provides significant re-use value to understand the neural dynamics of glucose metabolism and the haemodynamic response, the synchrony, and interaction between these measures, and the development of new single- and multi-modality image preparation and analysis procedures.

12 June 2020 in Magnetic Resonance in Medicine
Verified
Journal Article
Open access
PDF file
SMSarah McElroy
Sarah McElroy
GFGiulio Ferrazzi
Giulio Ferrazzi
MNMuhummad Sohaib Nazir
Muhummad Sohaib Nazir
KKKarl P. Kunze
Karl P. Kunze
RNRadhouene Neji
Radhouene Neji
SRSébastien Roujol
Sébastien Roujol
Purpose: To implement and evaluate a pseudorandom undersampling scheme for combined simultaneous multislice (SMS) balanced SSFP (bSSFP) and compressed‐sensing (CS) reconstruction to enable myocardial perfusion imaging with high spatial resolution and coverage at 1.5 T.Methods: A prospective pseudorandom undersampling scheme that is compatible with SMS‐bSSFP phase‐cycling requirements and CS was developed. The SMS‐bSSFP CS with pseudorandom and linear undersampling schemes were compared in a phantom. A high‐resolution (1.4 × 1.4 mm2) six‐slice SMS‐bSSFP CS perfusion sequence was compared with a conventional (1.9 × 1.9 mm2) three‐slice sequence in 10 patients. Qualitative assessment of image quality, perceived SNR, and number of diagnostic segments and quantitative measurements of sharpness, upslope index, and contrast ratio were performed.Results: In phantom experiments, pseudorandom undersampling resulted in residual artifact (RMS error) reduction by a factor of 7 compared with linear undersampling. In vivo, the proposed sequence demonstrated higher perceived SNR (2.9 ± 0.3 vs. 2.2 ± 0.6, P = .04), improved sharpness (0.35 ± 0.03 vs. 0.32 ± 0.05, P = .01), and a higher number of diagnostic segments (100% vs. 94%, P = .03) compared with the conventional sequence. There were no significant differences between the sequences in terms of image quality (2.5 ± 0.4 vs. 2.8 ± 0.2, P = .08), upslope index (0.11 ± 0.02 vs. 0.10 ± 0.01, P = .3), or contrast ratio (3.28 ± 0.35 vs. 3.36 ± 0.43, P = .7).Conclusion: A pseudorandom k‐space undersampling compatible with SMS‐bSSFP and CS reconstruction has been developed and enables cardiac MR perfusion imaging with increased spatial resolution and myocardial coverage, increased number of diagnostic segments and perceived SNR, and no difference in image quality, upslope index, and contrast ratio.

1 September 2016 in Tomography
Verified
Journal Article
Open access
DSDaniel Stäb
Daniel Stäb
JRJuergen Roessler
Juergen Roessler
KOKieran O'BRien
Kieran O'BRien
Christian Hamilton-CraigChristian Hamilton-Craig
Christian Hamilton-Craig
MBMarkus Barth
Markus Barth
Cardiac magnetic resonance imaging at ultra-high field (B0 ≥ 7 T) potentially provides improved resolution and new opportunities for tissue characterization. Although an accurate synchronization of the acquisition to the cardiac cycle is essential, electrocardiogram (ECG) triggering at ultra-high field can be significantly impacted by the magnetohydrodynamic (MHD) effect. Blood flow within a static magnetic field induces a voltage, which superimposes the ECG and often affects the recognition of the R-wave. The MHD effect scales with B0 and is particularly pronounced at ultra-high field creating triggering-related image artifacts. Here, we investigated the performance of a conventional 3-lead ECG trigger device and a state-of-the-art trigger algorithm for cardiac ECG synchronization at 7 T. We show that by appropriate subject preparation and by including a learning phase for the R-wave detection outside of the magnetic field, reliable ECG triggering is feasible in healthy subjects at 7 T without additional equipment. Ultra-high field cardiac imaging was performed with the ECG signal and the trigger events recorded in 8 healthy subjects. Despite severe ECG signal distortions, synchronized imaging was successfully performed. Recorded ECG signals, vectorcardiograms, and large consistency in trigger event spacing indicate high accuracy for R-wave detection.


28 March 2022 in Magnetic Resonance in Medicine
Verified
Journal Article
Open access
SMSarah McElroy
Sarah McElroy
GFGiulio Ferrazzi
Giulio Ferrazzi
MNMuhummad Sohaib Nazir
Muhummad Sohaib Nazir
CECarl Evans
Carl Evans
JFJoana Ferreira
Joana Ferreira
SRSébastien Roujol
Sébastien Roujol
Purpose: To implement and evaluate a simultaneous multi‐slice balanced SSFP (SMS‐bSSFP) perfusion sequence and compressed sensing reconstruction for cardiac MR perfusion imaging with full left ventricular (LV) coverage (nine slices/heartbeat) and high spatial resolution (1.4 × 1.4 mm2) at 1.5T.Methods: A preliminary study was performed to evaluate the performance of blipped controlled aliasing in parallel imaging (CAIPI) and RF‐CAIPI with gradient‐controlled local Larmor adjustment (GC‐LOLA) in the presence of fat. A nine‐slice SMS‐bSSFP sequence using RF‐CAIPI with GC‐LOLA with high spatial resolution (1.4 × 1.4 mm2) and a conventional three‐slice sequence with conventional spatial resolution (1.9 × 1.9 mm2) were then acquired in 10 patients under rest conditions. Qualitative assessment was performed to assess image quality and perceived signal‐to‐noise ratio (SNR) on a 4‐point scale (0: poor image quality/low SNR; 3: excellent image quality/high SNR), and the number of myocardial segments with diagnostic image quality was recorded. Quantitative measurements of myocardial sharpness and upslope index were performed.Results: Fat signal leakage was significantly higher for blipped CAIPI than for RF‐CAIPI with GC‐LOLA (7.9% vs. 1.2%, p = 0.010). All 10 SMS‐bSSFP perfusion datasets resulted in 16/16 diagnostic myocardial segments. There were no significant differences between the SMS and conventional acquisitions in terms of image quality (2.6 ± 0.6 vs. 2.7 ± 0.2, p = 0.8) or perceived SNR (2.8 ± 0.3 vs. 2.7 ± 0.3, p = 0.3). Inter‐reader variability was good for both image quality (ICC = 0.84) and perceived SNR (ICC = 0.70). Myocardial sharpness was improved using the SMS sequence compared to the conventional sequence (0.37 ± 0.08 vs 0.32 ± 0.05, p < 0.001). There was no significant difference between measurements of upslope index for the SMS and conventional sequences (0.11 ± 0.04 vs. 0.11 ± 0.03, p = 0.84).Conclusion: SMS‐bSSFP with multiband factor 3 and compressed sensing reconstruction enables cardiac MR perfusion imaging with three‐fold increased spatial coverage and improved myocardial sharpness compared to a conventional sequence, without compromising perceived SNR, image quality, upslope index or number of diagnostic segments.

20 October 2016 in NMR in Biomedicine
Verified
Journal Article
Closed access
PDF file
DSDaniel Stäb
Daniel Stäb
SBSteffen Bollmann
Steffen Bollmann
CLChristian Langkammer
Christian Langkammer
KBKristian Bredies
Kristian Bredies
MBMarkus Barth
Markus Barth