Chuang Fu

Chuang Fu

Auto-generated profile, based on publicly available information

Chuang Fu

Technology Research Center, China Southern Power Grid Company, Ltd., Guangzhou, China

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 August 2020 in IEEE Transactions on Power Delivery
Verified
Journal Article
Closed access
JWJuanjuan Wang
Juanjuan Wang
YGYingming Gong
Yingming Gong
CFChuang Fu
Chuang Fu
ZWZhaoxin Wen
Zhaoxin Wen
QWQiumei Wu
Qiumei Wu
The AC fault ride-through and support capability of LCC-HVDC have significant influence on the safe operation of power system. The ability of phase locked loop (PLL) to synchronize with the voltage phase under AC faults would affect the recovery performance of LCC-HVDC systems. This paper analyzes the influence of the conventional PLL on the subsequent commutation failure (SCF) of LCC-HVDC systems and points out that the conventional PLL has some problems such as slow dynamic response, significant frequency fluctuation, and coupling of phase and frequency detection under fault conditions. A novel PLL is proposed to address the problems. Cascade delayed signal cancellation operators are combined with a mathematical filter, forming a hybrid pre-filter to extract fundamental positive sequence voltage for the PLL. To reduce the fluctuation of PLL's frequency during AC faults, the estimated frequency is fixed when the fault is detected by a fault detector. As a consequence, the decoupling between phase detection and frequency detection is realized, and the proposed PLL's dynamic response performance is enhanced. Simulation results show that the proposed PLL can provide accurate phase reference for the DC control system and reduce the probability of SCFs of LCC-HVDC system

22 May 2025 in IEEE Transactions on Power Delivery
Verified
Journal Article
Closed access
ZYZhenxiao Yu
Zhenxiao Yu
JWJuanjuan Wang
Juanjuan Wang
CFChuang Fu
Chuang Fu
HWHaifeng Wang
Haifeng Wang
QHQihao He
Qihao He
QXQingming Xin
Qingming Xin
Current approaches for improving LCC-HVDC recovery ability after AC faults operate in isolation, neglecting the combined impacts of reactive power and phase shift on commutation margin. This paper proposes an integrated control combining reactive power control with firing angle correction to enhance LCC-HVDC system self-restoration. Firstly, this paper illustrates the influence of phase offset on commutation margin and analyzes the feasible region of DC transmission power and inverter-absorbed reactive power under the extinction angle control. Then, a method is proposed for modifying LCC-HVDC control considering dynamic reactive power balance and phase offset during AC fault and system recovery period. Specifically, upon AC fault detection, the system dynamically adjusts DC current and extinction angle references through reactive power control, while implementing different phase-offset compensation in different periods for firing angle correction. Additionally, the critical firing angle, satisfying commutation margin requirements at the intersection of reactive power control and extinction angle control, is established as the operational upper limit. Finally, the modified method is tested in the CIGRE HVDC, Guiguang II, Three Gorges-Shanghai and multi-feed DC Project models. Simulation results confirm significant improvements in commutation stability and DC current continuity during AC fault and system recovery.

1 January 2022 in Journal of Modern Power Systems and Clean Energy
Verified
Journal Article
Closed access
BRBilawal Rehman
Bilawal Rehman
CLChongru Liu
Chongru Liu
HLHuan Li
Huan Li
CFChuang Fu
Chuang Fu
WWWei Wei
Wei Wei
This paper provides a comprehensive analysis of local and concurrent commutation failure (CF) of multi-infeed high-voltage direct current (HVDC) system considering multi-infeed interaction factor (MIIF). The literature indicates that the local CF is not influenced by MIIF, whereas this paper concludes that both the local CF and concurrent CF are influenced by MIIF. The ability of remote converter to work under reduced reactive power enables its feature to support local converter via inter-connection link. The MIIF measures the strength of electrical connectivity between converters. Higher MIIF gives a clearer path to remote converter to support local converter, but at the same time, it provides an easy path to local converter to disturb remote converter under local fault. The presence of nearby converter increases the local commutation failure immunity index (CFII) while reducing concurrent CFII. Higher MIIF causes reactive power support to flow from remote converter to local converter, which reduces the chances of CF. A mathematical approximation to calculate the increase in local CFII for multi-infeed HVDC configurations is also proposed. A power flow approach is used to model the relation between MIIF and reactive power support from remote end. The local and concurrent CFIIs are found to be inverse to each other over MIIF; therefore, it is recommended that there is an optimal value of MIIF for all converters in close electric proximity to maintain CFII at a certain level. The numerical results of established model are compared with PSCAD/EMTDCsimulations. The simulation results show the details of the influence of MIIF on local CF and concurrent CF of multi-infeed HVDC, which validates the analysis presented.

6 July 2023 in IEEE Transactions on Power Delivery
Verified
Journal Article
Closed access
ZYZhenxiao Yu
Zhenxiao Yu
JWJuanjuan Wang
Juanjuan Wang
YLYuekun Liu
Yuekun Liu
CFChuang Fu
Chuang Fu
QHQihao He
Qihao He
ZWZhaoxin Wen
Zhaoxin Wen
An existing synchronous firing control is mainly composed of phase-locked loop (PLL), equidistant pulse control (EPC) and area minimum control (AMC), which can accurately predict the firing time in the steady state, while the accuracy deteriorates under AC faults. In this paper, in order to alleviate commutation failures in LCC-HVDC transmission project caused by single-phase-grounding (SPG) fault, the phase offset and the commutation margin under SPG faults are analyzed, and an improved synchronous firing control on suppressing LCC-HVDC commutation failures caused by SPG faults is proposed. First, the forward zero-crossing point of the grid-side non-fault line voltage is used to generate synchronous phases during the fault. Second, the phase offset of commutation voltage that is most likely to make the valve fail to be shut down was determined under SPG faults. Third, the phase offset was used to correct the EPC and the AMC respectively. Finally, in the Three Gorges Shanghai DC project model, the fault tests were carried out in the strong and the weak AC systems respectively. The results show that the improved control can improve the ability of LCC-HVDC projects to suppress commutator failure.

30 August 2022 in IEEE Transactions on Power Delivery
Verified
Journal Article
Closed access
ZYZhenxiao Yu
Zhenxiao Yu
JWJuanjuan Wang
Juanjuan Wang
CFChuang Fu
Chuang Fu
QWQiumei Wu
Qiumei Wu
YLYuekun Liu
Yuekun Liu
XLXiaohua Li
Xiaohua Li
Synchronous reference frame phase-locked loop (SRF-PLL) is adopted in HVDC synchronous firing control to output the synchronous phase. The synchronous performance directly affects the accuracy of the firing pulse, and even affects whether the inverter can successfully commutate during AC asymmetric faults. Therefore, an improved HVDC synchronous firing control method based on order switching and phase compensation is proposed in this paper. The improved SRF-PLL has the functions of extracting the fundamental frequency positive sequence (FFPS) phase and switching the order. When the fault detection detects that a fault has occurred, PLL is converted from the second-order system to the first-order system, so as to shorten the out-of-lock time and make it quickly enter the resynchronization. Then, for the phase shift of commutation voltages caused by fault, the zero-crossing sampling method is used to detect the change of the commutation voltage phases, and the synchronous phase of each commutation voltage is compensated selectively. Finally, the improved method is tested in CIGRE HVDC benchmark model and Three Gorges-Shanghai (3GS) DC project model, respectively. The results show that the improved method has better effect on suppressing commutation failure.

1 January 2024 in Journal of Modern Power Systems and Clean Energy
Verified
Journal Article
Closed access
JFJunjie Feng
Junjie Feng
WXWang Xiang
Wang Xiang
JWJinyu Wen
Jinyu Wen
CFChuang Fu
Chuang Fu
QXQingming Xin
Qingming Xin
ZYZhiyong Yuan
Zhiyong Yuan