Luciano Nava-Balanzar

Luciano Nava-Balanzar

Auto-generated profile, based on publicly available information

Luciano Nava-Balanzar

Division of Electrical Engineering and Electronics, Center for Engineering and Industrial Development (CIDESI), Queretaro, Mexico

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2014 in International Journal of Advanced Robotic Systems
Verified
Journal Article
Open access
LGLuis Govinda García-Valdovinos
Luis Govinda García-Valdovinos
TSTomás Salgado-Jiménez
Tomás Salgado-Jiménez
MBManuel Bandala
Manuel Bandala
LNLuciano Nava-Balanzar
Luciano Nava-Balanzar
RHRodrigo Hernández-Alvarado
Rodrigo Hernández-Alvarado
JCJosé Antonio Cruz-Ledesma
José Antonio Cruz-Ledesma
Underwater remotely operated vehicles (ROVs) play an important role in a number of shallow and deep-water missions for marine science, oil and gas extraction, exploration and salvage. In these applications, the motions of the ROV are guided either by a human pilot on a surface support vessel through an umbilical cord providing power and telemetry, or by an automatic pilot. In the case of automatic control, ROV state feedback is provided by acoustic and inertial sensors and this state information, along with a controller strategy, is used to perform several tasks such as station-keeping and auto-immersion/heading, among others. In this paper, the modelling, design and control of the Kaxan ROV is presented: i) The complete six degrees of freedom, non linear hydrodynamic model with its parameters, ii) the Kaxan hardware/software architecture, iii) numerical simulations in Matlab/Simulink platform of a model-free second order sliding mode control along with ocean currents as disturbances and thruster dynamics, iv) a virtual environment to visualize the motion of the Kaxan ROV and v) experimental results of a one degree of freedom underwater system.

5 September 2018 in Sensors
Verified
Journal Article
Open access
PDF file
NRNoe Rodriguez
Noe Rodriguez
JCJosé Vicente Cruz-Cruz
José Vicente Cruz-Cruz
AGAlejandro Gómez-Hernández
Alejandro Gómez-Hernández
RHRodrigo Hernandez
Rodrigo Hernandez
LNLuciano Nava-Balanzar
Luciano Nava-Balanzar
JSJorge Alberto Soto-Cajiga
Jorge Alberto Soto-Cajiga
This paper presents the improvement of an ultrasonic pulse generator for a pipeline inspection gauge (PIG), which uses 64 transducers for inspecting distances up to 100 km with an axial resolution fixed at 3 mm and variable speeds between 0 and 2 m/s. An ultrasonic pulse generator is composed of a high-voltage (HV) MOSFETs, driver logic and an HV power supply. We used a DC-HV DC converter device as the HV power supply because it reduces the size of the ultrasound system considerably. However, pipeline geometry and inspection effects such as hammer and shock cause a variable pulse repetition frequency (PRF), producing voltage drops, poor quality of the HV pulse generated, failures in the dimensioning of defects and damage to devices by over-voltage. Our improvement is to implement a control scheme to maintain the high quality of the HV regardless of the variable PRF. To achieve this, we characterized three transfer functions of the DC-HV DC converter, varying the connected load to 10%, 45% and 80%. For the characterization, we used the least squares technique, considering an autoregressive exogenous (ARX) model. Later, we compared three control schemes: (1) proportional-integral-derivative (PID) tuned by simultaneous optimization of several responses (SOSR), (2) PID tuned by a neural network (NN) and (3) PI tuned by the analytical design method (ADM). The metrics used to compare the control schemes were the recovery time, the maximum over-voltage and the excess energy when the shock and hammer effects happen to occur. Finally, to verify the improvement of the HV pulser, we compared the ultrasonic pulses generated for various frequencies and amplitudes using the pulse generator with and without the control scheme.

29 September 2021 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Open access
NRNoe Rodriguez
Noe Rodriguez
LNLuciano Nava-Balanzar
Luciano Nava-Balanzar
LBLeonardo Barriga
Leonardo Barriga
In invasive mechanical ventilation (IMV), it is critical that the flow value is estimated correctly, as it is used as a trigger variable for ventilatory assistance. Furthermore, the numerical integration of the flow allows the calculation of the total volume per breath (tidal volume), which clinicians use to identify trauma or lung capacity in the patient. The current COVID-19 pandemic has demonstrated the need to develop safe and efficient techniques for measuring this spirometry variable because many mechanical ventilators delivered to hospitals were unable to measure it directly. A good device to estimate flow is a D-lite sensor, which works by the Venturi effect, is cheap, reusable, and proximal to the patient. However, the regressions applied to the flow estimation model are limited for use in real conditions. This article presents a flow estimation method that uses a D-Lite device, a fraction of inspired oxygen (FiO 2 ) cell, and two pressure sensors as critical items. Our novel method adapts the dichotomous search algorithm instead of conventional regression algorithms to estimate flow using a D-lite sensor; this change in the standard procedure allowed us a fast calibration process, a good low-flow estimation, and low computational time for flow estimation. The method was validated experimentally to compute the tidal volume according to the measurement requirement error range of +/−10%. The consideration of FiO 2 percentage in the gas mixture and the good low-flow estimation make this novel method useful for real ventilation conditions. The flow calculations have been performed at different ambient conditions and compared with gas analyzers show an average relative error of up to 4.86%. Finally, we present an analysis of the error flow estimation considering the variation in each variable. Technical recommendations for applying this novel method to achieve IMV safely are presented, based on the capabilities of the embedded system used by developers.

14 March 2018 in IEEE Transactions on Computers
Verified
Journal Article
Open access
NRNoe Rodriguez
Noe Rodriguez
AGA. Gomez-Hernandez
A. Gomez-Hernandez
LNL. Nava-Balanzar
L. Nava-Balanzar
Hugo Jimenez HernandezHugo Jimenez Hernandez
Hugo Jimenez Hernandez
JSJorge Alberto Soto-Cajiga
Jorge Alberto Soto-Cajiga
In this manuscript, we present a redundant data storage system based on NAND flash memory chips for in-line Pipeline Inspection Gauges (PIGs). The system is the next step for a technique that reduces data from 1,024 to 37 bytes by 80 transducers used for straight-beam ultrasonic inspection. Each inspection is costly, because PIGs check pipelines up to 100 Km, collecting data every 3 mm and reaching speeds of 2 m/s. These conditions require that the storage system must be redundant, and able to maintain a minimum data flow, thus avoiding bottlenecks. To achieve this, we analyzed the variables that influence the inspection process in real-time, and we structured our Flash Translation Layer (FTL) to eliminate the latencies generated by the computation of the Error Correcting Codes (ECC) and redundancy bytes. Our controller computes the ECC and redundancy bytes while it transfers the information to the cache register of the selected die in the memory chips. At the hardware level, we interleaved 8 NAND flash chips in a Redundant Array of Independent Disks (RAID) type-6 architecture. We tested the storage system considering the incorrect response of up to 2 chips and ensuring a throughput up to 7.28 MB/s. Finally, we expanded the analysis of the data flow, whereby this system is profitable for different pipeline diameters or compression techniques.

1 January 2017
Verified
Conference Paper
Open access
LNL. Nava-Balanzar
L. Nava-Balanzar
JSJ. L. Sanchez-Gaytán
J. L. Sanchez-Gaytán
FFF. Fonseca-Navarro
F. Fonseca-Navarro
TST. Salgado-Jiménez
T. Salgado-Jiménez
LGL. G. Garcia-Valdovinos
L. G. Garcia-Valdovinos
ARA. Ramirez-Martinez
A. Ramirez-Martinez

7 August 2018 in International Journal of Circuit Theory and Applications
Verified
Journal Article
Closed access
PDF file
AVAlberto Vazquez-Cervantes
Alberto Vazquez-Cervantes
THTeresa Hernández‐Díaz
Teresa Hernández‐Díaz
DCDiana‐Margarita Córdova‐Esparza
Diana‐Margarita Córdova‐Esparza
LNLuciano Nava‐Balanzar
Luciano Nava‐Balanzar
JSJ. A. Soto‐Cajiga
J. A. Soto‐Cajiga
Hugo Jimenez HernandezHugo Jimenez Hernandez
Hugo Jimenez Hernandez