Ranjan Kumar Behera

Ranjan Kumar Behera

Auto-generated profile, based on publicly available information

Ranjan Kumar Behera

Department of Electrical Engineering, Indian Institute of Technology Patna, Patna, India

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 May 2021 in IEEE Transactions on Industry Applications
Verified
Journal Article
Closed access
SPSurya Prakash
Surya Prakash
JSJitendra Kumar Singh
Jitendra Kumar Singh
RBRanjan Kumar Behera
Ranjan Kumar Behera
AMArijit Mondal
Arijit Mondal
This article presents a type-3 second-order generalized integrator phase-locked loop (SOGI-PLL) algorithm for single-phase system. Disturbances, such as dc offset and harmonics, are present in the practical grid voltages, due to occurrence of faults, sensors, and analog-to-digital converters. The type-3 SOGI-PLL exhibits fast dynamic performance with gain and phase-lead compensation. However, the general type-3 SOGI-PLL introduces fundamental frequency oscillations in the estimated quantities at the output, when grid voltage contains disturbances. The incorporation of filters for suppression of frequency oscillations, due to dc offset, reduces the bandwidth of PLL, which affects the dynamic response of PLL by introducing phase delay. Thus, a modified notch-filter SOGI (MNF-SOGI) based type-3 SOGI-PLL is proposed with frequency adaptive control to eliminate the phase error, without affecting the dynamic performance. A detailed analysis is presented on the effect of dc offset and scaling error. To enhance dynamic response, filtering, and stability designed guideline based on settling time is also discussed. The proposed type-3 MNF-SOGI-PLL has better grid parameter estimation and fast response with inherent dc offset rejection capability. The effectiveness of the proposed type-3 MNF-SOGI-PLL is evaluated under various grid disturbance conditions and experimentally verified.

13 November 2023 in IEEE Transactions on Industry Applications
Verified
Journal Article
Open access
SBSwapan Kumar Baksi
Swapan Kumar Baksi
RBRanjan Kumar Behera
Ranjan Kumar Behera
UMUtkal Ranjan Muduli
Utkal Ranjan Muduli
This paper introduces a novel switched-capacitor-based 9-level inverter topology to meet IEEE standards for low total harmonic distortion (THD) in grid-connected inverters. The new design addresses the trade-off between increasing output voltage levels to reduce harmonics and the consequent rise in device count. The proposed topology is streamlined, consisting of 12 switches, 3 capacitors, 2 diodes, and a single DC source. Comparative analysis with similar topologies confirms the advantages of the new design. The experimental results show that the proposed inverter achieves a THD of 13.58% in its output voltage. The topology is validated through its application in a single-stage, three-phase photovoltaic system connected to the grid. Simulations are conducted using MATLAB/Simulink to test the system's performance. Furthermore, hardware-in-the-loop experiments are performed using OPAL-RT 5700 real-time simulators to further substantiate the efficacy of the proposed topology.

7 May 2020 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
BCBheemaiah Chikondra
Bheemaiah Chikondra
UMUtkal Ranjan Muduli
Utkal Ranjan Muduli
RBRanjan Kumar Behera
Ranjan Kumar Behera
The multi-phase machine (MM) drives are best suitable for safety-critical applications due to its inherent fault-tolerant capability. The fault-tolerant operation of MM drives is challenging and necessary for applications such as off-shore ship propulsion, high-way electric vehicles, and more electric aircraft. A two-level voltage source inverter (VSI) fed five-phase induction motor (FPIM) drive has been considered for the post-fault performance assessment. In this paper, an improved fault-tolerant direct torque control (DTC) technique is proposed for the FPIM drive based on virtual vector (VV)s} assessment under the open-phase fault condition. The theoretical analysis is carried out to investigate the impact of VVs on the change in torque as well as flux response at different speeds and loading conditions. Based on this analysis, a modified lookup table, flux, and torque hysteresis bands are designed to improve the functioning of the fault-tolerant DTC of FPIM drive. The FPIM drive performance is analyzed and tested experimentally with an open-phase fault. Studies have confirmed the reliability and superiority of the proposed DTC controller over existing post-fault solutions. In addition, the robustness of the FPIM drive at steady-state and dynamic operating conditions is evaluated from the given results, including the transition from pre-to-post fault operation.

28 May 2020 in IEEE Transactions on Transportation Electrification
Verified
Journal Article
Open access
UMUtkal Ranjan Muduli
Utkal Ranjan Muduli
Balanthi Abdul BeigBalanthi Abdul Beig
Balanthi Abdul Beig
Khaled Ali Al JaafariKhaled Ali Al Jaafari
Khaled Ali Al Jaafari
Jamal AlsawalhiJamal Alsawalhi
Jamal Alsawalhi
RBRanjan Kumar Behera
Ranjan Kumar Behera
This article presents a new open-end winding induction motor (OEWIM)-based dual-motor differential four-wheel drive (D4WD) for the electric vehicle (EV). Constant speed operation through cruise control is achieved using direct torque control (DTC) algorithm. The redundant vectors are used in the switching vector selection of the DTC algorithm to achieve balanced battery currents. Fault-tolerant operation (FTO) of the drive is demonstrated, where the EV will work with full torque even if one of the inverters in rear motor drive or front motor drive or both fail. The dynamic model of the proposed drive is presented. The proposed drive and FTO are verified through simulation as per the FTP-75 driving cycle. An experimental prototype of the proposed drive is developed, and the abovementioned algorithms are verified experimentally as per the FTP-75 and HFET driving cycles. Both the simulation and experimental results are presented, and these results agree with the theoretical observations. Stable operation of EV for the entire test cycle under normal operation, as well as inverter fault conditions, is demonstrated.

29 June 2021 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Open access
UMUtkal Ranjan Muduli
Utkal Ranjan Muduli
Balanthi Abdul BeigBalanthi Abdul Beig
Balanthi Abdul Beig
RBRanjan Kumar Behera
Ranjan Kumar Behera
Khaled Ali Al JaafariKhaled Ali Al Jaafari
Khaled Ali Al Jaafari
Jamal AlsawalhiJamal Alsawalhi
Jamal Alsawalhi
For high-power electric vehicles (EVs), the drive propulsion based on induction motors is emerging as economical alternative. Compared to conventional induction motors, the open-end winding induction motor (OEWIM) requires only half the dc-bus voltage for the given torque. The EV power train based on the dual two-level voltage-source inverter (VSI)-fed OEWIM with isolated dc sources is used in this research. For uniform state-of-charge (SoC) distribution, the power flow from each isolated source needs to be controlled. A two-stage model-predictive direct torque control (MPDTC) scheme is proposed to balance the SoC of batteries by proper selection of the VSI voltage vectors. The proposed MPDTC scheme is free from weighting factor tuning and uses a ranking method to predict the optimal voltage vectors. The superiority of the proposed controller in terms of battery SoC balancing is demonstrated. The performance of the proposed MPDTC EV drive is verified for the FTP75 and HFET driving cycles under different operating conditions, both by simulation and hardware experimental tests.

3 December 2021 in IEEE Access
Verified
Journal Article
Open access
ADArobinda Dash
Arobinda Dash
DBDurgesh Prasad Bagarty
Durgesh Prasad Bagarty
PHPrakash Kumar Hota
Prakash Kumar Hota
UMUtkal Ranjan Muduli
Utkal Ranjan Muduli
KHKhalifa Al Hosani
Khalifa Al Hosani
RBRanjan Kumar Behera
Ranjan Kumar Behera
The phase and frequency correction with a three-phase grid-connected solar photovoltaic-distributed static compensator (SPV-DSTATCOM) is challenging. For grid-connected SPV-DSTATCOM, this paper proposes a cascaded enhanced second-order general integrator frequency locked loop with prefilter (CESOGI-FLL-WPF) controller. The suggested work uses the available SPV power to meet the active power requirement of local loads. Furthermore, after addressing the local load demands, the extra SPV power is pumped into the grid. The voltage source converter (VSC) operates as a DC/AC inverter when sunlight is available and as a DSTATCOM when sunlight is not available. As a result, the VSC contributes to reactive power compensation, improved power quality, improved power factor, zero voltage regulation, efficient load balancing, and increased device utilization. The CESOGI-FLL-WPF controller is able to extract the fundamental components from nonlinear load currents, resulting in superior harmonics compensation and a highly rapid and stable dynamic response of the overall system under varied conditions. The suggested system is modelled and simulated using the MATLAB/Simulink software. The proposed SPV-DSTATCOM prototype is tested in the laboratory to ensure that it performs as expected.