Matthieu De Beule

Matthieu De Beule

Auto-generated profile, based on publicly available information

Matthieu De Beule

FEops, Technologiepark- Zwijnaarde 122, Ghent 9052, Belgium

Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 October 2018 in International Journal for Numerical Methods in Biomedical Engineering
Verified
Journal Article
Closed access
PDF file
MPMathias Peirlinck
Mathias Peirlinck
KSKevin L. Sack
Kevin L. Sack
PBPieter De Backer
Pieter De Backer
Pedro MoraisPedro Morais
Pedro Morais
PSPatrick Segers
Patrick Segers
MBMatthieu De Beule
Matthieu De Beule

28 May 2020 in Journal of Interventional Cardiology
Verified
Journal Article
Open access
PDF file
PAPatricio Astudillo
Patricio Astudillo
PMPeter Mortier
Peter Mortier
JBJohan Bosmans
Johan Bosmans
OBOle De Backer
Ole De Backer
PJPeter de Jaegere
Peter de Jaegere
JDJoni Dambre
Joni Dambre
Anatomic landmark detection is crucial during preoperative planning of transcatheter aortic valve implantation (TAVI) to select the proper device size and assess the risk of complications. The detection is currently a time-consuming manual process influenced by the image quality and subject to operator variability. In this work, we propose a novel automatic method to detect the relevant aortic landmarks from MDCT images using deep learning techniques. We trained three convolutional neural networks (CNNs) with 344 multidetector computed tomography (MDCT) acquisitions to detect five anatomical landmarks relevant for TAVI planning: the three basal attachment points of the aortic valve leaflets and the left and right coronary ostia. The detection strategy used these three CNN models to analyse a single MDCT image and yield three segmentation volumes as output. These segmentation volumes were averaged into one final segmentation volume, and the final predicted landmarks were obtained during a postprocessing step. Finally, we constructed the aortic annular plane, defined by the three predicted hinge points, and measured the distances from this plane to the predicted coronary ostia (i.e., coronary height). The methodology was validated on 100 patients. The automatic landmark detection was able to detect all the landmarks and showed high accuracy as the median distance between the ground truth and predictions is lower than the interobserver variations (1.5 mm [1.1–2.1], 2.0 mm [1.3–2.8] with a paired difference −0.5 ± 1.3 mm and p value <0.001). Furthermore, a high correlation is observed between predicted and manually measured coronary heights (for both R2 = 0.8). The image analysis time per patient was below one second. The proposed method is accurate, fast, and reproducible. Embedding this tool based on deep learning in the preoperative planning routine may have an impact in the TAVI environments by reducing the time and cost and improving accuracy.

1 December 2010 in EuroIntervention
Verified
Journal Article
Closed access
PMPeter Mortier
Peter Mortier
MBMatthieu De Beule
Matthieu De Beule
GDGabriele Dubini
Gabriele Dubini
YHYutaka Hikichi
Yutaka Hikichi
YMYoshinobu Murasato
Yoshinobu Murasato
JOJohn Ormiston
John Ormiston
The Official Journal of EuroPCR and the European Association of Percutaneous Cardiovascular Interventions (EAPCI)

5 August 2016 in BioMedical Engineering OnLine
Verified
Journal Article
Open access
PDF file
CCClaudio Chiastra
Claudio Chiastra
FIFrancesco Iannaccone
Francesco Iannaccone
MGMaik J. Grundeken
Maik J. Grundeken
FGFrank J. H. Gijsen
Frank J. H. Gijsen
PSPatrick Segers
Patrick Segers
JWJolanda J. Wentzel
Jolanda J. Wentzel
Coronary hemodynamics and physiology specific for bifurcation lesions was not well understood. To investigate the influence of the bifurcation angle on the intracoronary hemodynamics of side branch (SB) lesions computational fluid dynamics simulations were performed. A parametric model representing a left anterior descending—first diagonal coronary bifurcation lesion was created according to the literature. Diameters obeyed fractal branching laws. Proximal and distal main branch (DMB) stenoses were both set at 60 %. We varied the distal bifurcation angles (40°, 55°, and 70°), the flow splits to the DMB and SB (55 %:45 %, 65 %:35 %, and 75 %:25 %), and the SB stenoses (40, 60, and 80 %), resulting in 27 simulations. Fractional flow reserve, defined as the ratio between the mean distal stenosis and mean aortic pressure during maximal hyperemia, was calculated for the DMB and SB (FFRSB) for all simulations. The largest differences in FFRSB comparing the largest and smallest bifurcation angles were 0.02 (in cases with 40 % SB stenosis, irrespective of the assumed flow split) and 0.05 (in cases with 60 % SB stenosis, flow split 55 %:45 %). When the SB stenosis was 80 %, the difference in FFRSB between the largest and smallest bifurcation angle was 0.33 (flow split 55 %:45 %). By describing the ΔPSB−QSB relationship using a quadratic curve for cases with 80 % SB stenosis, we found that the curve was steeper (i.e. higher flow resistance) when bifurcation angle increases (ΔP = 0.451*Q + 0.010*Q 2 and ΔP = 0.687*Q + 0.017*Q 2 for 40° and 70° bifurcation angle, respectively). Our analyses revealed complex hemodynamics in all cases with evident counter-rotating helical flow structures. Larger bifurcation angles resulted in more pronounced helical flow structures (i.e. higher helicity intensity), when 60 or 80 % SB stenoses were present. A good correlation (R2 = 0.80) between the SB pressure drop and helicity intensity was also found. Our analyses showed that, in bifurcation lesions with 60 % MB stenosis and 80 % SB stenosis, SB pressure drop is higher for larger bifurcation angles suggesting higher flow resistance (i.e. curves describing the ΔPSB−QSB relationship being steeper). When the SB stenosis is mild (40 %) or moderate (60 %), SB resistance is minimally influenced by the bifurcation angle, with differences not being clinically meaningful. Our findings also highlighted the complex interplay between anatomy, pressure drops, and blood flow helicity in bifurcations.

1 December 2019 in Morphologie
Verified
Journal Article
Closed access
PAP. Astudillo
P. Astudillo
MBM. De Beule
M. De Beule
JDJ. Dambre
J. Dambre
PMP. Mortier
P. Mortier

1 January 2010
Verified
Book Chapter
Closed access
PDF file
AHA. Van Haver
A. Van Haver
JQJ. Quintelier
J. Quintelier
MBM. De Beule
M. De Beule
PVP. Verdonk
P. Verdonk
FAFredrik Almqvist
Fredrik Almqvist
PBPatrick De Baets
Patrick De Baets