In recent decades, wireless healthcare detection has been demonstrated to be an efficient method for monitoring the health condition of targets; it has involved the detection of motion and vital sign signals with minimal discomfort. Self-injection-locked (SIL) radar systems exhibit several useful advantages over conventional continuous-wave (CW) radar systems in healthcare applications, including a low system complexity, high sensitivity, and high clutter immunity. Several approaches to detecting vital sign signals and locations using SIL radar systems have been proposed. This paper summarizes developments in vital sign detection and localization. Finally, some results of detecting animals using SIL radar systems are presented.
3 November 2022 in IEEE Transactions on Microwave Theory and Techniques
The distributed-multiple-input multiple-output (MIMO) continuous-wave (CW) radar with low-intermediate frequency (low-IF) receiver that is proposed in this work uses uniform linear array (ULA) antennas to estimate the direction of arrival (DOA) of subjects and recover Doppler signals by the digital beamforming (DBF) technique. Without using any modulation bandwidth, the location of multiple subjects can be determined from the known antenna positions and the estimated DOAs. This work proves that the Doppler-weighted method improves the extraction of the initial phase of the baseband signal. With respect to the recovery of each subject’s vital signs, the modified-DBF is utilized to separate individual Doppler signals while nullifying interference. The frequency estimation algorithm (FEA) is used to improve the Doppler frequency and angular resolution by 50% and 44%, respectively, in the detection of two closely spaced moving metal plates. Finally, the presented system is experimentally validated by determining the locations and vital signs of people sitting side-by-side. The estimated DOA and position errors were less than 3.3 $^{\circ}$ and $10$ cm, respectively. With a 25 s sensing period, the errors in the measured respiration rates (RRs) and heart rates (HRs) were less than 1.2 breath/min and $3$ beats/min, respectively.
4 December 2020 in IEEE Transactions on Microwave Theory and Techniques
This article presents the combination of a self-injection-locked (SIL) radar with frequency-modulated continuous-wave (FMCW) and switched phased-array (SPA) techniques to locate multiple people and detect their vital signs with high resolution and high sensitivity. The proposed system utilizes a subharmonic upconverter/downconverter with a 1.675-2.175-GHz chirp local oscillator (LO) signal to convert between a 2.45-GHz SIL IF signal and a 5.8-6.8-GHz FMCW RF signal. It transmits the FMCW RF signal and receives the echo signal using a transmit (Tx) antenna and a switched receive (Rx) antenna array, respectively, and processes the SIL IF signal to produce a range-azimuth map (RAM) that displays the positions of all people, their respiration rates (RRs), and their heart rates (HRs) in the monitoring region. The key advantage of combining the FMCW and SPA techniques is the provision of higher spatial resolution than obtained using each technique alone. This article also proposes a Doppler-weighted RAM to improve the identifiability of the images that are generated by two persons close to each other. Finally, the presented system was experimentally validated by measuring the locations and vital signs of up to five seated persons at a range of more than 1.5 m, of which two persons were seated almost shoulder by shoulder.
3 February 2020 in IEEE Transactions on Microwave Theory and Techniques
This article presents a single-conversion self-injection-locked (SIL) (SCSIL) hybrid mode radar with a novel frequency estimation algorithm, which improves the range resolution in a frequency-modulated continuous-wave (FMCW) mode and simultaneously detects the vital signs of multiple subjects in the CW mode. The system architecture includes an SIL oscillator (SILO), a frequency converter, two antennas, and a noncoherent frequency demodulator. Due to the frequency-phase relationship in the spectrum of the beat signal in the FMCW mode, the distance to the closely spaced subjects can be determined. Moreover, the algorithm will identify the most dominant component and remove it from the input signal, and the steps are repeated until the residual-to-input energy ratio is less than the threshold value. This iterative method can thus distinguish multiple signals whose frequencies are close to each other and can support a superresolution analysis in both FMCW and CW modes. In an experiment, the radar with a 150-MHz bandwidth and a sensing period of 20 s can simultaneously provide accurate range and vital sign information of two adjacent subjects with radial and azimuth spacings of 60 cm and 5°, respectively.
This paper presents a system for remotely monitoring the displacement of a moving target. The quadrature selfinjection-locked (QSIL) radar uses an additional phase shifter to the traditional SIL radar to repeatedly switch the phase delay of injection signals between 0° and 90°. Hence, it can be utilized to determine the displacement of the moving target without the distortion due to large injection angles. Moreover, this paper proposes the measurement- and differential-based methods to calibrate dc and phase offsets before arctangent demodulation is performed to extract the displacement information. In the experiments, a 2.4-GHz prototype was implemented to detect the moving metal plate with various peak-to-peak displacements from 0.25 to 5 cm, which are 0.02× to 0.4× the operating wavelength, with a root-mean-square error of less than 1.5%. Also, the prototype was verified to detect the cardiopulmonary activities of a seated subject.
15 December 2020 in IEEE Transactions on Microwave Theory and Techniques
The proposed frequency-offset self-injection-locked (FOSIL) radar combines two independent SIL radar front-ends with up/down-mixers. The transmit frequency can be held constant by properly adjusting the injection phases and amplitudes of two oscillators. Therefore, electromagnetic interference (EMI) in the monitoring of a moving subject using conventional SIL radars is eliminated, and multiple FOSIL radars can be operated simultaneously within a limited bandwidth. In this work, one RF mixer with digital frequency demodulation is used to extract the motion of the target relative to the radar, reducing the system complexity and eliminating the I/Q imbalance and dc offset calibration. The proposed system substantially improves the SNR over that of the conventional SIL radar by 28 dB, by mitigating the flicker noise and the large Doppler shift. In noncontact vital sign sensing experiments, the 5.8-GHz industrial scientific medical (ISM) band FOSIL radar prototype had a sensing range of 8 m, and its frequency swing range was reduced by over 96% without or with clutter signals. Two FOSIL radars with a frequency spacing of 2 MHz can yield exact information on the cardiopulmonary activities of two subjects at the same time in the experimental environment.