16 October 2025 in IEEE Transactions on Power Delivery
With the continuous development of the global energy internet and the increasing power demand, the voltage level of Gas Insulated Transmission Line (GIL) is continually increasing. To meet the operational requirements for higher voltage levels, this paper proposes a novel 550 kV GIL design method based on a 252 kV prototype. Firstly, a multi-stage optimization strategy is creatively proposed through correlation and sensitivity analyses. Secondly, multi-objective optimization techniques, including Response Surface Methodology (RSM), Non-dominated Sorting Genetic Algorithm II (NSGA-II), and Technique for Order Preference by Similarity to Ideal Solution (TOPSIS), are formulated to optimize the geometry and dimensions of key GIL components. The optimization results indicate that the designed 550 kV GIL meets insulation and mechanical strength requirements while achieving significant miniaturization. Compared to the current minimum enclosure radius, the optimized enclosure radius is reduced by 13.39%, and the SF6 gas usage is reduced by approximately 24.70%. Additionally, lightning impulse test and hydraulic test further demonstrate the effectiveness and reliability of the optimized design. This study provides a systematic and efficient approach for designing higher voltage GIL, realizing a more compact and environmentally sustainable solution.
20 October 2025 in IEEE Transactions on Dielectrics and Electrical Insulation
The basin-type insulator, a critical component of gas-insulated transmission lines (GIL), significantly influences system reliability through its stress distribution. This study develops a coupled electromagnetic–temperature–fluid–stress field model for a 550 kV GIL basin-type insulator to investigate its stress distribution under operational conditions. We measure the thermal conductivity (K), heat capacity (Cp), elastic modulus (E), Poisson’s ratio (v), and thermal expansion coefficient (α) of epoxy resin from 293.15 K to 423.15 K, quantifying their temperature dependence for numerical modeling. A stepwise coupling strategy is proposed, first resolving bi-directional coupling among the electromagnetic field, temperature field, and fluid field to determine temperature distribution, then evaluating the stress field response. Innovatively, the penalty function method and Mooney-Rivlin model are introduced to simulate the contact characteristics of the semiconductive rubber buffer layer. Simulation results reveal that a temperature gradient (maximum difference of 15 K) drives thermal stress, with a maximum von Mises stress of 43.16 MPa, significantly higher than the 2.06 MPa from the static model. Stress concentration occurs at the triple-point and concave surface, with the concave surface exhibiting higher stress than the convex surface (difference of 5.13 MPa). The buffer layer reduces interfacial Tresca stress to 5.39 MPa, though local strain remains elevated. These findings provide a theoretical foundation for geometric optimization and reliability enhancement of insulator.
23 January 2026 in IEEE Transactions on Dielectrics and Electrical Insulation
Converter transformers are critical for the reliable operation of high-voltage direct current systems, yet they operate under harsh conditions involving high electrical stress, elevated temperatures, and mechanical vibrations. Conventional cellulose pressboard exhibits limited resistance to these combined stresses, which motivates the use of meta-aramid pressboard as a promising alternative insulation material. To elucidate the multi-field coupling aging mechanisms of meta-aramid pressboard, this study develops a thermal-electrical-mechanical multi-field coupling aging platform. The degree of polymerization is employed to quantitatively evaluate macroscopic aging progression. Scanning electron microscopy is used to observe surface morphology evolution, including fiber peeling, microcrack generation, and pore formation, while X-ray diffraction characterizes changes in crystal structure, diffraction intensity, crystallinity, and microcrystalline size at different aging stages. Breakdown strength is measured to evaluate the evolution of dielectric withstand capability under different aging conditions. Furthermore, molecular dynamics simulations are carried out to calculate cohesive energy density and the number of hydrogen bonds under different field combinations, providing molecular-scale insight into structural deterioration. The results indicate that thermal aging induces more pronounced microstructural and mechanical degradation of the meta-aramid pressboard than electrical or mechanical loading, while superimposed electrical and mechanical stresses mainly act to further intensify the deterioration caused by thermal aging. Overall, the combined action of thermal, electrical, and mechanical stresses produces a synergistic effect that significantly accelerates the hierarchical degradation of meta-aramid pressboard.
8 June 2026 in High Voltage
Oil–pressboard system is the main insulation form of oil‐immersed transformers, which is prone to partial discharge (PD) and subsequent faults due to contamination or moisture ingress. To investigate the evolutionary characteristics of PD streamers under varying voltages and insulation dimensions, streamer images were captured using a high‐speed camera system. An image restoration algorithm was proposed, which integrates the Retinex theory with bilateral filtering and k‐dimensional tree (KD‐tree)‐based methods. This algorithm allows for the enhancement of image contrast while ensuring that edge details are preserved and fragmented streamer channels are reconnected. By varying the applied voltage, needle–plate gap length and pressboard thickness, patterns in streamer area and the number of bifurcations were analysed. These variations were microscopically explained in terms of electric field distortion and the dielectric matching between oil and pressboard insulation. It was found that larger streamer areas are produced by higher voltages and longer needle–plate gaps. Additionally, under elevated voltages or prolonged energisation, multiple streamer patterns are generated due to the presence of photoionisation and bubble formation. Furthermore, an increased number of bifurcations is observed with longer gaps and more uniform dielectric matching between oil and pressboard. The results obtained here enrich the evolution mechanism of PD and provide theoretical guidance for the dielectric matching of transformer oil and pressboard.
30 March 2026 in High Voltage
During long‐term operation of converter transformers, the internal oil–pressboard insulation undergoes irreversible degradation. Partial discharge in the weakened insulation will cause the formation of a large number of bubbles in the insulating oil. The dynamic behaviour of bubbles in the strong electric field region will threaten the safe operation of the transformer. To clarify the dynamic behaviour of bubbles in oil under electrothermal ageing, the migration trajectories and deformation process of bubbles in oil under partial discharge at different ageing stages are investigated experimentally, and the influence of the initial bubble radius on migration trajectory, velocity and morphological changes are examined through numerical simulation. The experimental results indicate that as the ageing time increases, the influence of the kinematic viscosity of the insulating oil on bubble migration increases, and the influence of the electric field strength distribution on bubble migration increases and then decreases. It also becomes more difficult for bubbles to return to a spherical shape. The simulation results indicate that as the initial bubble radius increases, bubbles move more easily away from the strong electric field region and more easily enter the rising stage. The maximum degree of longitudinal stretching of bubbles increases.