Zhaoyang Kang

Zhaoyang Kang

Auto-generated profile, based on publicly available information

Zhaoyang Kang

Shandong Provincial Key Laboratory of UHV Transmission Technology and Equipment School of Electrical Engineering Shandong University Jinan China

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 September 2023 in High Voltage
Verified
Journal Article
Open access
ZKZhaoyang Kang
Zhaoyang Kang
Fuqiang RenFuqiang Ren
Fuqiang Ren
HZHongru Zhang
Hongru Zhang
JYJingjing Yang
Jingjing Yang
KHKaining Hou
Kaining Hou
HWHuaxin Wen
Huaxin Wen
Basin‐type insulator often has small cracks due to stress concentration. The current method cannot accurately reflect the stress condition of the insulator to find the stress concentration areas. To solve these problems, a method for detecting two‐dimensional plane stress ( δ 1 and δ 2 ) within different depth ranges in a basin‐type insulator is proposed based on critically refracted longitudinal (LCR) wave. First, the acoustoelastic equation characterising the relationship between the variation of LCR wave propagation time and the plane stress was derived. Next, the propagation characteristics of LCR wave in epoxy resin samples were investigated. Then, the stress distribution within different depth ranges of the insulator subjected to hydraulic load was measured using the proposed method, including direction ( θ ), δ 1 and δ 2 . The results show that the magnitude of the stress alone cannot accurately characterise the stress state. Points with equal distances to the centre have similar stress magnitudes, but their directions are not the same. With increasing depth, θ remains essentially unchanged at the same location, while δ 1 and δ 2 decrease, and the rate of decrease varies at different locations. Comparing the measured and simulated data, the results showed that they were in good agreement, and the maximum errors of stress value and θ were 0.69 MPa and 2.97°, respectively, which confirmed the feasibility and accuracy of the stress detection in the proposed method.

3 May 2022 in IEEE Transactions on Dielectrics and Electrical Insulation
Verified
Journal Article
Closed access
JYJingjing Yang
Jingjing Yang
KHKaining Hou
Kaining Hou
HWHongbin Wu
Hongbin Wu
ZKZhaoyang Kang
Zhaoyang Kang
Hongshun LiuHongshun Liu
Hongshun Liu
QLQing-quan Li
Qing-quan Li
For the development of converter transformer applications, research on the discharge characteristics in transformer oil is required. This article presents an analysis of the streamer discharge characteristics caused by a needle-plate electrode in oil-pressboard insulation under ac voltage and discharge images on the time scale of microseconds. Based on the discharge image, a Gaussian filter, image segmentation of the Otsu algorithm, and Canny edge detection are used to detect the edge of the discharge image. By extracting the discharge profile image, the discharge characteristics are effectively identified. The size and quantity of particles in transformer oil during the discharge are analyzed. Research on the characteristics of streamer discharge propagation is not only helpful for understanding the process of discharge but also has important significance for converter transformer design from the perspective of inhibiting streamer discharge.

16 October 2025 in IEEE Transactions on Power Delivery
Verified
Journal Article
Closed access
KZKang Zhaoyang
Kang Zhaoyang
HKHou Kaining
Hou Kaining
YGYang Guangdi
Yang Guangdi
WHWu Hongbin
Wu Hongbin
Fuqiang RenFuqiang Ren
Fuqiang Ren
WPWang Peijin
Wang Peijin
With the continuous development of the global energy internet and the increasing power demand, the voltage level of Gas Insulated Transmission Line (GIL) is continually increasing. To meet the operational requirements for higher voltage levels, this paper proposes a novel 550 kV GIL design method based on a 252 kV prototype. Firstly, a multi-stage optimization strategy is creatively proposed through correlation and sensitivity analyses. Secondly, multi-objective optimization techniques, including Response Surface Methodology (RSM), Non-dominated Sorting Genetic Algorithm II (NSGA-II), and Technique for Order Preference by Similarity to Ideal Solution (TOPSIS), are formulated to optimize the geometry and dimensions of key GIL components. The optimization results indicate that the designed 550 kV GIL meets insulation and mechanical strength requirements while achieving significant miniaturization. Compared to the current minimum enclosure radius, the optimized enclosure radius is reduced by 13.39%, and the SF6 gas usage is reduced by approximately 24.70%. Additionally, lightning impulse test and hydraulic test further demonstrate the effectiveness and reliability of the optimized design. This study provides a systematic and efficient approach for designing higher voltage GIL, realizing a more compact and environmentally sustainable solution.

8 October 2025 in Energies
Verified
Journal Article
Open access
PDF file
KHKaining Hou
Kaining Hou
ZKZhaoyang Kang
Zhaoyang Kang
DHDongxin He
Dongxin He
Fuqiang RenFuqiang Ren
Fuqiang Ren
QLQing-quan Li
Qing-quan Li
Partial Discharge (PD) measurement is one of the effective methods for assessing the internal insulation condition of power transformers in factories and substations. The pulse current signals generated by PD within transformer windings are significantly influenced by the winding structure during their propagation from the discharge source to the external measurement system. This influence may lead to misinterpretation of the insulation status, particularly in the analysis of PD measurement results. Such effects are closely related to the signal transmission path and distance and exhibit a strong correlation with the winding transfer function, manifesting as attenuation, distortion, or delay of the measured signals compared to the original PD waveforms. Therefore, it is essential to investigate the impact of the discharge path on the propagation characteristics of transformer windings and its effect on PD waveforms. This paper establishes a simplified distributed parameter model of a 180-turn single-winding multi-conductor transmission line using the finite element method and mathematical modeling, deriving the transfer functions between the winding head or winding end and various internal discharge positions. By injecting different types of PD waveforms collected in the laboratory at various discharge locations within the winding, the alterations of PD signals propagated to the winding head and winding end are simulated, and clustering analysis is performed on the propagated PD signals of different types.

20 October 2025 in IEEE Transactions on Dielectrics and Electrical Insulation
Verified
Journal Article
Closed access
KZKang Zhaoyang
Kang Zhaoyang
WHWu Hongbin
Wu Hongbin
HKHou Kaining
Hou Kaining
YGYang Guangdi
Yang Guangdi
ZRZhu Ran
Zhu Ran
WPWang Peijin
Wang Peijin
The basin-type insulator, a critical component of gas-insulated transmission lines (GIL), significantly influences system reliability through its stress distribution. This study develops a coupled electromagnetic–temperature–fluid–stress field model for a 550 kV GIL basin-type insulator to investigate its stress distribution under operational conditions. We measure the thermal conductivity (K), heat capacity (Cp), elastic modulus (E), Poisson’s ratio (v), and thermal expansion coefficient (α) of epoxy resin from 293.15 K to 423.15 K, quantifying their temperature dependence for numerical modeling. A stepwise coupling strategy is proposed, first resolving bi-directional coupling among the electromagnetic field, temperature field, and fluid field to determine temperature distribution, then evaluating the stress field response. Innovatively, the penalty function method and Mooney-Rivlin model are introduced to simulate the contact characteristics of the semiconductive rubber buffer layer. Simulation results reveal that a temperature gradient (maximum difference of 15 K) drives thermal stress, with a maximum von Mises stress of 43.16 MPa, significantly higher than the 2.06 MPa from the static model. Stress concentration occurs at the triple-point and concave surface, with the concave surface exhibiting higher stress than the convex surface (difference of 5.13 MPa). The buffer layer reduces interfacial Tresca stress to 5.39 MPa, though local strain remains elevated. These findings provide a theoretical foundation for geometric optimization and reliability enhancement of insulator.

1 January 2026 in IEEE Transactions on Dielectrics and Electrical Insulation
Verified
Journal Article
Closed access
HWHongbin Wu
Hongbin Wu
ZKZhaoyang Kang
Zhaoyang Kang
ZYZichao Yuan
Zichao Yuan
FMFanbo Meng
Fanbo Meng
Fuqiang RenFuqiang Ren
Fuqiang Ren
QLQing-quan Li
Qing-quan Li