Hanns-Christian Breit

Hanns-Christian Breit

Auto-generated profile, based on publicly available information

Hanns-Christian Breit

Department of Radiology, University Hospital Basel, Basel, Switzerland

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 September 2023 in Radiology: Artificial Intelligence
Verified
Journal Article
Closed access
JWJakob Wasserthal
Jakob Wasserthal
HBHanns-Christian Breit
Hanns-Christian Breit
MMManfred T. Meyer
Manfred T. Meyer
MPMaurice Pradella
Maurice Pradella
DHDaniel Hinck
Daniel Hinck
MSMartin Segeroth
Martin Segeroth
To present a deep learning segmentation model that can automatically and robustly segment all major anatomic structures on body CT images. In this retrospective study, 1204 CT examinations (from 2012, 2016, and 2020) were used to segment 104 anatomic structures (27 organs, 59 bones, 10 muscles, and eight vessels) relevant for use cases such as organ volumetry, disease characterization, and surgical or radiation therapy planning. The CT images were randomly sampled from routine clinical studies and thus represent a real-world dataset (different ages, abnormalities, scanners, body parts, sequences, and sites). The authors trained an nnU-Net segmentation algorithm on this dataset and calculated Dice similarity coefficients to evaluate the model’s performance. The trained algorithm was applied to a second dataset of 4004 whole-body CT examinations to investigate age-dependent volume and attenuation changes. The proposed model showed a high Dice score (0.943) on the test set, which included a wide range of clinical data with major abnormalities. The model significantly outperformed another publicly available segmentation model on a separate dataset (Dice score, 0.932 vs 0.871; P < .001). The aging study demonstrated significant correlations between age and volume and mean attenuation for a variety of organ groups (eg, age and aortic volume [rs = 0.64; P < .001]; age and mean attenuation of the autochthonous dorsal musculature [rs = −0.74; P < .001]). The developed model enables robust and accurate segmentation of 104 anatomic structures. The annotated dataset ( https://doi.org/10.5281/zenodo.6802613 ) and toolkit ( https://www.github.com/wasserth/TotalSegmentator ) are publicly available. Keywords: CT, Segmentation, Neural Networks Supplemental material is available for this article. © RSNA, 2023 See also commentary by Sebro and Mongan in this issue.

1 February 2025 in Radiology
Verified
Journal Article
Closed access
TDTugba Akinci D'Antonoli
Tugba Akinci D'Antonoli
LBLucas K. Berger
Lucas K. Berger
AIAshraya Indrakanti
Ashraya Indrakanti
NVNathan Vishwanathan
Nathan Vishwanathan
JWJakob Weiss
Jakob Weiss
JWJakob Wasserthal
Jakob Wasserthal
TotalSegmentator MRI is an open-source, user-friendly tool that provides automatic, robust sequence-independent segmentations of major anatomic structures on MRI scans; the ready-to-use online tool is available at https://totalsegmentator.com .

12 November 2022 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
TRThilo Rusche
Thilo Rusche
JVJan Vosshenrich
Jan Vosshenrich
DWDavid Winkel
David Winkel
RDRicardo Donners
Ricardo Donners
MSMartin Segeroth
Martin Segeroth
HBHanns-Christian Breit
Hanns-Christian Breit
Objectives: The objectives of this study were to assess patient comfort when imaged on a newly introduced 0.55T low-field magnetic resonance (MR) scanner system with a wider bore opening compared to a conventional 1.5T MR scanner system. Materials and Methods: In this prospective study, fifty patients (mean age: 66.2 ± 17.0 years, 22 females, 28 males) underwent subsequent magnetic resonance imaging (MRI) examinations with matched imaging protocols at 0.55T (MAGNETOM FreeMax, Siemens Healthineers; Erlangen, Germany) and 1.5T (MAGNETOM Avanto Fit, Siemens Healthineers; Erlangen, Germany) on the same day. MRI performed between 05/2021 and 07/2021 was included for analysis. The 0.55T MRI system had a bore opening of 80 cm, while the bore diameter of the 1.5T scanner system was 60 cm. Four patient groups were defined by imaged body regions: (1) cranial or cervical spine MRI using a head/neck coil (n = 27), (2) lumbar or thoracic spine MRI using only the in-table spine coils (n = 10), (3) hip MRI using a large flex coil (n = 8) and (4) upper- or lower-extremity MRI using small flex coils (n = 5). Following the MRI examinations, patients evaluated (1) sense of space, (2) noise level, (3) comfort, (4) coil comfort and (5) overall examination impression on a 5-point Likert-scale (range: 1= “much worse” to 5 = “much better”) using a questionnaire. Maximum noise levels of all performed imaging studies were measured in decibels (dB) by a sound level meter placed in the bore center. Results: Sense of space was perceived to be “better” or “much better” by 84% of patients for imaging examinations performed on the 0.55T MRI scanner system (mean score: 4.34 ± 0.75). Additionally, 84% of patients rated noise levels as “better” or “much better” when imaged on the low-field scanner system (mean score: 3.90 ± 0.61). Overall sensation during the imaging examination at 0.55T was rated as “better” or “much better” by 78% of patients (mean score: 3.96 ± 0.70). Quantitative assessment showed significantly reduced maximum noise levels for all 0.55T MRI studies, regardless of body region compared to 1.5T, i.e., brain MRI (83.8 ± 3.6 dB vs. 89.3 ± 5.4 dB; p = 0.04), spine MRI (83.7 ± 3.7 dB vs. 89.4 ± 2.6 dB; p = 0.004) and hip MRI (86.3 ± 5.0 dB vs. 89.1 ± 1.4 dB; p = 0.04). Conclusions: Patients perceived 0.55T new-generation low-field MRI to be more comfortable than conventional 1.5T MRI, given its larger bore opening and reduced noise levels during image acquisition. Therefore, new concepts regarding bore design and noise level reduction of MR scanner systems may help to reduce patient anxiety and improve well-being when undergoing MR imaging.

29 March 2022 in Der Radiologe
Verified
Journal Article
Open access
PDF file
JVJan Vosshenrich
Jan Vosshenrich
HBHanns-Christian Breit
Hanns-Christian Breit
MBMichael Bach
Michael Bach
EMElmar M. Merkle
Elmar M. Merkle
Zusammenfassung: Hintergrund: Niederfeld-Magnetresonanztomographie(MRT)-Geräte bieten aufgrund niedrigerer Herstellungskosten und geringerer baulicher Anforderungen für Installation und Betrieb eine Chance zur Kostenreduktion. Fragestellung: Mögliche Kostenreduktionen in Anschaffung, Einbringung und Unterhalt durch die Verwendung neuer Niederfeld-MRT-Systeme. Material und Methoden: Übersicht über die wichtigsten Kostenfaktoren und Evaluierung des Einsparpotenzials eines 0,55-T-Niederfeld-MRT der neuesten Generation im Vergleich zu 1,5‑ und 3‑T-MRT-Systemen in der klinischen Routine. Ergebnisse: Im Anschaffungspreis liegt das Einsparpotenzial eines 0,55-T- im Vergleich zu einem 1,5-T-MRT-System bei etwa 40–50 %. Das um 25 % niedrigere Gewicht des Systems verringert die Transportkosten, die geringere Größe des Geräts erlaubt bei einem ebenerdigen Betriebsplatz die Einbringung mittels ferngesteuertem fahrbarem Robotersystem ohne Eröffnung der Außenfassade. Eine Quench-Leitung muss nicht installiert werden. Die Kosten für Einbringung und Installation sind insgesamt bis zu 70 % niedriger als bei Hochfeldsystemen. Die Wartungskosten eines 0,55-T-Geräts liegen etwa 45 % unter denen eines 1,5-T-Geräts bei vergleichbarem Servicevertrag. Weitere potenzielle Kostenreduktionen ergeben sich durch die geringere Raumgröße und einen potenziell geringeren Energieverbrauch für Untersuchungen und Kühlung. Schlussfolgerung: Die Verwendung von MRT-Systemen mit niedrigerer Feldstärke bieten großes ökonomisches und ökologisches Potenzial für Kliniken und Praxisbetreiber.

1 August 2021 in European Journal of Radiology
Verified
Journal Article
Open access
HBHanns C. Breit
Hanns C. Breit
KBKai T. Block
Kai T. Block
DWDavid Winkel
David Winkel
JGJulian E. Gehweiler
Julian E. Gehweiler
MHMaurice Henkel
Maurice Henkel
THTobias J. Heye
Tobias J. Heye
To evaluate potential confounding factors in the quantitative assessment of liver fibrosis and cirrhosis using T1 relaxation times. The study population is based on a radiology-information-system database search for abdominal MRI performed from July 2018 to April 2019 at our institution. After applying exclusion criteria 200 (59 ± 16 yrs) remaining patients were retrospectively included. 93 patients were defined as liver-healthy, 40 patients without known fibrosis or cirrhosis, and 67 subjects had a clinically or biopsy-proven liver fibrosis or cirrhosis. T1 mapping was performed using a slice based look-locker approach. A ROI based analysis of the left and the right liver was performed. Fat fraction, R2*, liver volume, laboratory parameters, sex, and age were evaluated as potential confounding factors. T1 values were significantly lower in healthy subjects without known fibrotic changes (1.5 T MRI: 575 ± 56 ms; 3 T MRI: 857 ± 128 ms) compared to patients with acute liver disease (1.5 T MRI: 657 ± 73 ms, p < 0.0001; 3 T MRI: 952 ± 37 ms, p = 0.028) or known fibrosis or cirrhosis (1.5 T MRI: 644 ± 83 ms, p < 0.0001; 3 T MRI: 995 ± 150 ms, p = 0.018). T1 values correlated moderately with the Child-Pugh stage at 1.5 T (p = 0.01, ρ = 0.35). T1 mapping is a capable predictor for detection of liver fibrosis and cirrhosis. Especially age is not a confounding factor and, hence, age-independent thresholds can be defined. Acute liver diseases are confounding factors and should be ruled out before employing T1-relaxometry based thresholds to screen for patients with liver fibrosis or cirrhosis.

1 September 2020 in Radiology: Artificial Intelligence
Verified
Journal Article
Closed access
CFChristian Federau
Christian Federau
SCSoren Christensen
Soren Christensen
NSNino Scherrer
Nino Scherrer
JOJohanna M. Ospel
Johanna M. Ospel
VSVictor Schulze-Zachau
Victor Schulze-Zachau
SKSebastian Kozerke
Sebastian Kozerke
The segmentation and detection performance of a generic three-dimensional U-Net trained on a combination of human-labeled clinical stroke diffusion-weighted (DW) images and synthetic stroke DW imag... Purpose To compare the segmentation and detection performance of a deep learning model trained on a database of human-labeled clinical stroke lesions on diffusion-weighted (DW) images to a model tr...