Chenglong Feng

Chenglong Feng

Auto-generated profile, based on publicly available information

Chenglong Feng

School of Medicine, Shanghai YangZhi Rehabilitation Hospital (Shanghai Sunshine Rehabilitation Center), Tongji University, Shanghai, China

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 October 2024 in Laser & Photonics Reviews
Verified
Journal Article
Closed access
JSJian Shen
Jian Shen
YZYong Zhang
Yong Zhang
LZLei Zhang
Lei Zhang
Jingchi LiJingchi Li
Jingchi Li
CFChenglong Feng
Chenglong Feng
YSYikai Su
Yikai Su

11 August 2022 in Computer Methods in Biomechanics and Biomedical Engineering
Verified
Journal Article
Closed access
Wentao FengWentao Feng
Wentao Feng
XYXianda Yang
Xianda Yang
JYJie Yao
Jie Yao
CFChenglong Feng
Chenglong Feng
LWLizhen Wang
Lizhen Wang
Yubo FanYubo Fan
Yubo Fan
Leaflet damage has been documented to occur while deploying a transcatheter aortic valve (TAV) due to mechanical loads during the crimping procedures. In this study, the impact of compressive stress on folded leaflets was measured to investigate the mechanism of traumatic leaflet tissue damage. Numerical simulation of TAV crimping procedure was adapted to calculate stress magnitude and distribution of leaflets. A 20 mm balloon expanding short stent TAV with 0.25 mm thickness leaflets was used in the simulation. Then the calculated stresses were applied on leaflet material (bovine pericardium) samples by loading experiments. Mechanical properties evaluation combined with histological and microscopy observation were used to investigate the tissue damage. The elastic modulus and the tensile strength of the tissue began to decrease significantly at 2 MPa stress and 2.5 MPa stress, respectively. No significant differences were observed at 0–1.5 MPa stress. When the TAV was crimped to 14 Fr and 12 Fr, the 2 MPa greater areas on leaflets increased from 18.17% to 76.96%. 2 MPa compressive stress might be the threshold value for leaflet damage. The TAV crimping size should be paid attention to avoid the compressive stress higher than 2 MPa.

28 July 2020 in IEEE Access
Verified
Journal Article
Open access
LMLiu Mingxin
Liu Mingxin
BTBin Tang
Bin Tang
XZXiaoxia Zheng
Xiaoxia Zheng
QWQiang Wang
Qiang Wang
SWSiyuan Wang
Siyuan Wang
CFChenglong Feng
Chenglong Feng
To overcome the space-time adaptive processing (STAP) performance loss caused by discarding the non-uniform parts of difference coarray and copulse for coprime sampling structure under the condition of single-frequency operation, this paper proposes a new STAP algorithm to improve the precision of filter weight vector estimation by the dual-frequency operation. By selecting a single proper additional operation frequency, we can obtain the different coarray and copulse, thus fill two missed virtual sensors and pulses of the difference structures in the single-frequency operation simultaneously. Compared with the single-frequency operation, the dual-frequency operation method can acquire the bigger uniform linear array (ULA) and coherent processing interval (CPI) pulse train to improve the system degrees of freedom (DOF), and result in higher angle-Doppler resolution. In addition, the coprime array has the little mutual coupling effect because of the larger inter-sensors spacing. Therefore, the resulting method can alleviate mutual coupling and enhance the system DOF.

16 September 2025 in IEEE Transactions on Neural Systems and Rehabilitation Engineering
Verified
Journal Article
Open access
FWFengxian Wu
Fengxian Wu
YLYaming Liu
Yaming Liu
HJHucheng Jiang
Hucheng Jiang
LLLuyao Li
Luyao Li
CFChenglong Feng
Chenglong Feng
Wenxin NiuWenxin Niu
Wenxin Niu
Walking is a fundamental human motor pattern supported by multi-level neural control. Previous research has extensively explored cortical responses during routine walking and complex gait scenarios. However, these studies often conflate basic gait control with cognitive demands, making it unclear how distinct cortical responses are elicited by automated versus discrete gait tasks. To address this, integrated EEG–fNIRS enables high spatiotemporal resolution characterization of cortical responses during these tasks in real-world conditions. This study proposes a framework that incorporates three gait tasks and simultaneously collects EEG and fNIRS data to characterize cortical responses and neurovascular coupling between automated and discrete gait tasks. Eighteen healthy participants performed continuous walking (CW), isolated gait phase (IGPT), and single-limb stance (SS) tasks during simultaneous EEG–fNIRS recording. Task-Related Component Analysis (TRCA) extracted task-related features, validated against channel-averaging methods. The coupling coefficient between EEG and fNIRS signals was computed using time-lagged maximum cross-correlation analysis. XGBoost classified tasks using different data inputs (channel averaging vs. TRCA, unimodal vs. bimodal). Repeated-measures ANOVA assessed inter-task differences. Results showed that beta-band suppression was stronger in IGPT vs. CW (p = 0.040), while SS showed higher fNIRS activation than CW (p = 0.026). TRCA significantly enhanced within-class similarity and between-class discriminability of EEG–fNIRS features across all tasks (p < 0.05), and revealed task-specific alpha-band neurovascular coupling, with stronger negative coupling in IGPT vs. CW (p = 0.046). Multimodal TRCA-based fusion achieved 74.51% classification accuracy, significantly outperformed EEG-Avg (49.02%, p = 0.042) and fNIRS-Avg (47.06%, p = 0.038). This study establishes an EEG–fNIRS framework that reveals task-specific cortical responses and neurovascular coupling differences between automated and discrete gait tasks, providing a foundation for further exploration of gait control and rehabilitation.

18 December 2019 in Cardiovascular Engineering and Technology
Verified
Journal Article
Closed access
PDF file
Wentao FengWentao Feng
Wentao Feng
YTYishan Teng
Yishan Teng
JYJie Yao
Jie Yao
XYXianda Yang
Xianda Yang
CFChenglong Feng
Chenglong Feng
Yubo FanYubo Fan
Yubo Fan

1 April 2021 in Journal of Biomechanics
Verified
Journal Article
Closed access
CFChenglong Feng
Chenglong Feng
LWLizhen Wang
Lizhen Wang
PXPeng Xu
Peng Xu
ZCZhaowei Chu
Zhaowei Chu
JYJie Yao
Jie Yao
Yubo FanYubo Fan
Yubo Fan