Jace Rozsa

Jace Rozsa

Auto-generated profile, based on publicly available information

Jace Rozsa

Department of Electrical and Computer Engineering Carnegie Mellon University 5000 Forbes Avenue Pittsburgh PA 15213 USA

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 June 2020 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
YSYixin Song
Yixin Song
JRJace Rozsa
Jace Rozsa
JMJoan Barros de Magalhaes
Joan Barros de Magalhaes
SSShea Smith
Shea Smith
BKBenjamin Karlinsey
Benjamin Karlinsey
Shiuh-hua Wood ChiangShiuh-hua Wood Chiang
Shiuh-hua Wood Chiang
We describe a charge detector that utilizes a high-gain, differential solid-state amplifier with active reset and a novel technique to measure the gain using a custom optoelectronic system. Implemented in a 180-nm complementary metal-oxide-semiconductor (CMOS) process, the amplifier realizes a high gain of 8.9 μV/e- and single-pass rms noise of 475 e- for 10 ms time interval with a 300 kHz lowpass filter corner. Operating at a sampling frequency of 10 kHz, the active reset extends the dynamic range of the detector. The amplifier is the first instance of a charge detector that combines a differential topology, active reset, and small feedback capacitors for low-noise, high-gain, high-dynamic-range, and robust operations. The proposed optoelectronic test system injects an adjustable input photocurrent as low as 33 pA to precisely quantify the detector’s gain without the need for a known calibration capacitance. The amplifier is directly wire-bonded to a PCB that has a built-in 1 cm2 Faraday cup. The gain and noise performance have been characterized for a range of input capacitance and the results show good agreement with simulations. The test system additionally demonstrates the ability to inject a time-varying input at the pA levels to characterize the dynamic response of the detector. An electrospray system confirms that the detector responds to free-space charge and that it can process an input as large as 56,000 e- without saturation. The compact and high sensitivity design qualify the device for use in charge detection applications such as mass spectrometry and space instruments.

1 May 2020 in Review of Scientific Instruments
Verified
Journal Article
Closed access
PDF file
JRJace Rozsa
Jace Rozsa
YSYixin Song
Yixin Song
DWDevon Webb
Devon Webb
NDNaomi Debaene
Naomi Debaene
AKAustin Kerr
Austin Kerr
AHAaron Hawkins
Aaron Hawkins
We present a novel and thorough simulation technique to understand image charge generated from charged particles on a printed-circuit-board detector. We also describe a custom differential amplifier to exploit the near-differential input to improve the signal-to-noise-ratio of the measured image charge. The simulation technique analyzes how different parameters such as the position, velocity, and charge magnitude of a particle affect the image charge and the amplifier output. It also enables the designer to directly import signals into circuit simulation software to analyze the full signal conversion process from the image charge to the amplifier output. A novel measurement setup using a Venturi vacuum system injects single charged particles (with diameters in the 100 s of microns range) through a PCB detector containing patterned electrodes to verify our simulation technique and amplifier performance. The measured differential amplifier presented here exhibits a gain of 7.96 µV/e− and a single-pass noise floor of 1030 e−, which is about 13× lower than that of the referenced commercial amplifier. The amplifier also has the capability to reach a single-pass noise floor lower than 140 e−, which has been shown in Cadence simulation.

15 April 2021 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
JRJace Rozsa
Jace Rozsa
YSYixin Song
Yixin Song
AKAustin Kerr
Austin Kerr
NDNaomi Debaene
Naomi Debaene
DADaniel Austin
Daniel Austin
AHAaron Hawkins
Aaron Hawkins
In image charge sensing applications, a tradeoff exists between minimizing detector capacitance for improved amplifier noise performance and adding repeated sensing stages for noise improvement through averaging of repeated signals. In order to understand this tradeoff, the link between image charge detector geometry and capacitance is studied through finite element analysis. This knowledge is then used to present a novel method for determining the relevant detector parameters such that the system noise performance for a given amplifier is optimized. This method is independent of specific amplifier parameters. We find that the optimum noise performance does not lie in simply arbitrarily increasing the number of sensing stages, but depends on the amount of parasitic input capacitance to the amplifier. The greater the parasitic capacitance, the greater the number of stages for the optimum detector. The optimum number of stages is also highly dependent on the detector geometry.

12 February 2025 in Advanced Materials Technologies
Verified
Journal Article
Open access
KZKe Zhong
Ke Zhong
JRJace Rozsa
Jace Rozsa
Dinesh K. PatelDinesh K. Patel
Dinesh K. Patel
Lining YaoLining Yao
Lining Yao
GFGary K. Fedder
Gary K. Fedder
MIMohammad Islam
Mohammad Islam
A method for creating superhydrophobic surfaces is presented by aerosolizing polymer solutions into micrometer‐sized droplets and converting them into microgel particles during spatially controlled deposition using an aerosol jet printer. The polymer solutions are composed of marginally hydrophobic disulfide‐polydimethylsiloxane (DS‐PDMS) in three solvents with varying vapor pressures. The experiments, combined with an analytical model, demonstrate that solvents with high vapor pressures evaporate from the droplets during flight from the printer nozzle to the substrate. This evaporation increases the DS‐PDMS volume fraction in the droplets above the polymer gelation threshold. As a result, the droplets transform into microgel particles. This transformation leads to the formation of rough, superhydrophobic surfaces. Conversely, solvents with lower vapor pressures do not evaporate sufficiently, preventing DS‐PDMS volume fraction from reaching the gelation threshold. These droplets coalesce upon deposition, producing smooth surfaces with hydrophobicity similar to intrinsic DS‐PDMS. Heating the surfaces to 90 °C or above eliminates superhydrophobicity by de‐gelling the DS‐PDMS, allowing droplet coalescence. Potential applications of this method include droplet manipulation, microreactors for reactant mixing, water‐oil separation, and retardation of droplet evaporation.