2 March 2020 in IEEE Transactions on Nuclear Science
A sensitivity characterization of a Xilinx Artix-7 FPGA against 14.2 MeV neutrons is presented. The content of the internal SRAMs and flip-flops were downloaded in a PC and compared with a golden version of it. Flipped cells were identified and classified as cells of the configuration RAM, BRAM, or flip-flops. SBUs and MCUs with multiplicities ranging from 2 to 8 were identified using a statistical method. Possible shapes of multiple events are also investigated, showing a trend to follow wordlines. Finally, MUSCA SEP3 was used to make assesment for actual environments and an improvement of SEU injection test is proposed.
1 January 2016 in Neurocomputing
6 August 2015 in IEEE Transactions on Nuclear Science
This paper presents a methodology to emulate Single Event Upsets (SEUs) in Field Programmable Gate Array (FPGA) flip-flops (FFs). Since the content of a FF is not modifiable through the FPGA configuration memory bits, a dedicated design is required for fault injection in the FFs. The method proposed in this paper is a hybrid approach that combines FPGA partial reconfiguration and extra logic added to the circuit under test, without modifying its operation. This approach has been integrated into a fault-injection platform, named NESSY (Non intrusive ErrorS injection SYstem), developed by our research group. Finally, this paper includes results on a Virtex-5 FPGA demonstrating the validity of the method on the ITC'99 benchmark set and a Feed-Forward Equalization (FFE) filter. In comparison with other approaches in the literature, this methodology reduces the resource consumption introduced to carry out the fault injection in FFs, at the cost of adding very little time overhead ( 1.6 μs per fault).
1 February 2018 in IEEE Transactions on Nuclear Science
This paper presents a SEU sensitivity characterization at ultra-low bias voltage of three generations of COTS SRAMs manufactured in 130 nm, 90 nm and 65 nm CMOS processes. For this purpose, radiation tests with 14.2 MeV neutrons were performed for SRAM power supplies ranging from 0.5 V to 3.15 V. The experimental results yielded clear evidences of the SEU sensitivity increase at very low bias voltages. These results have been cross-checked with predictions issued from the modeling tool MUlti-SCAles Single Event Phenomena Predictive Platform (MUSCA-SEP3). Large-scale SELs and SEFIs, observed in the 90-nm and 130-nm SRAMs respectively, are also presented and discussed.
11 July 2016 in IEEE Transactions on Nuclear Science
Recently, the occurrence of multiple events in static tests has been investigated by checking the statistical distribution of the difference between the addresses of the words containing bitflips. That method has been successfully applied to Field Programmable Gate Arrays (FPGAs) and the original authors indicate that it is also valid for SRAMs. This paper presents a modified methodology that is based on checking the XORed addresses with bitflips, rather than on the difference. Irradiation tests on CMOS 130 & 90 nm SRAMs with 14-MeV neutrons have been performed to validate this methodology. Results in high-altitude environments are also presented and cross-checked with theoretical predictions. In addition, this methodology has also been used to detect modifications in the organization of said memories. Theoretical predictions have been validated with actual data provided by the manufacturer.
1 February 1996 in IEEE Transactions on Computer-Aided Design of Integrated Circuits and Systems
This paper describes a new method to estimate the area of data paths generated during a High Level Synthesis (HLS) process, when the information concerning the circuit is not yet complete. Our method is more accurate and considers more factors than those used by other HLS systems of which we are aware. Our main concern is the interconnection area, often neglected by HLS systems, which has a strong influence on the final circuit area being optimized, as well as a high dependency on the technology used and on the circuit area itself. Predicting the area of a design layout with accuracy is important because it allows one to foresee whether the design will satisfy the area constraints, and will lend the allocator towards the best design among several possibilities with guarantees. Our estimations of the final standard-cell layout area are similar, or even more accurate, than those obtained following methods used by low-level design systems, which have much more information available. Due to the performance penalty their relatively high complexity will produce, these methods are unusable in an HLS system exploring a wide design space. Our estimation, on the contrary, has a low complexity and can be repeated time and again as the HLS design space is searched.