Wen Liu

Wen Liu

Auto-generated profile, based on publicly available information

Wen Liu

State Key Laboratory of Electrical Insulation and Power Equipment, Xi’an Jiaotong University , Xi’an 710049, China

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
5 January 2019 in The International Journal of Advanced Manufacturing Technology
Verified
Journal Article
Closed access
PDF file
WLWen Liu
Wen Liu
HWHaiying Wei
Haiying Wei
CHChu Huang
Chu Huang
FYFengbo Yuan
Fengbo Yuan
YZYi Zhang
Yi Zhang

1 January 2021 in Acta Physica Sinica
Verified
Journal Article
Open access
PDF file
FJFu-Chun Jiang
Fu-Chun Jiang
RLRui-You Liu
Rui-You Liu
DPDong-Sheng Peng
Dong-Sheng Peng
WLWen Liu
Wen Liu
GCGuang-Yue Chai
Guang-Yue Chai
Hong-Lei WuHong-Lei Wu
Hong-Lei Wu
根据白光发光二极管(LED)发光光谱特点, 通过分析蓝光光谱和由蓝光激发黄色荧光粉产生的黄光光谱的交点(即整个光谱的波谷点)特性, 利用常规可见光光谱仪设计了一套基于光谱法的LED稳态热阻测量系统, 采用正常的驱动电流通过一定的函数算法进行拟合得到整体光谱波谷处归一化光谱强度与结温间敏感系数K和定标函数, 再根据温升曲线可计算出任意工作状态下LED结温相对于基底的温升, 并结合LED的热耗散功率从而得到LED的稳态热阻. 本方法避免了类似正向压降法采用极小电流定标而需要高速数据采集模块和高速取样转换等模块导致的设备昂贵的缺点,从而降低了成本. 最后采用本文设计的系统和美国Mentor Graphics公司的T3Ster仪器分别对多种LED进行测量并对结果进行了比较, 发现稳态热阻最大偏离度仅为3.64%. 表明本文设计的系统和方法在不需要昂贵设备的情况下便可以达到与Mentor Graphics公司的T3Ster仪器相仿的精度. 本方法采用非传统式光谱法测量, 具有可远程实时在线检测LED结温和低成本的特点, 对LED封装结构没有任何限制, 因此比Mentor Graphics公司T3Ster设备采用的电压法有更广的应用范围, 具有一定的实用价值.

1 July 2021 in AIP Advances
Verified
Journal Article
Open access
PDF file
YWYongsheng Wang
Yongsheng Wang
WLWen Liu
Wen Liu
WDWeidong Ding
Weidong Ding
There are many advantages in obtaining low-temperature plasmas that are rich in active particles by atmospheric pressure glow discharge, so there has been a lot of research on the acquisition method and application of it. However, there is a lack of knowledge about the mechanism of atmospheric pressure glow discharge driven by an AC resonant power supply. In this paper, we describe our study of the characteristic differences between half-cycle positive and negative atmospheric pressure glow discharges driven in open air by an AC resonant power supply, and we describe our analysis of the associated physical mechanism. The comparison and analysis of experimental results indicate that both positive-cycle and negative-cycle discharges led to typical glow discharge and no streamer discharge appeared in the discharge process. There were still charged particles in the discharge channel when the discharge current was zero. With increasing amplitude of the output voltage of the power supply, the glow area near the electrode surface and the plasma distribution area in the discharge channel increased. When the output voltage of the power supply was low, the negative polarity discharge was more likely to form in the gap of the pin-to-plate electrode. In the AC discharge process, the α-mode discharge was dominant, and the developing speed of the positive-cycle discharge was faster than that of the negative-cycle discharge. The polarity effect became less obvious with the increase in the output voltage amplitude of the power supply.