Manojkumar Raju Ramteke

Manojkumar Raju Ramteke

Auto-generated profile, based on publicly available information

Manojkumar Raju Ramteke

Department of Electrical Engineering, Visvesvaraya National Institute of Technology, Nagpur, India

Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 September 2017 in IEEE Transactions on Industry Applications
Verified
Journal Article
Closed access
NRNaresh Kumar Reddi
Naresh Kumar Reddi
MRManoj R. Ramteke
Manoj R. Ramteke
HSHiralal M. Suryawanshi
Hiralal M. Suryawanshi
KKKoteswararao Kothapalli
Koteswararao Kothapalli
SGSnehal P. Gawande
Snehal P. Gawande
A new isolated current-fed zero-current switched (ZCS) front-end DC/DC converter based multilevel inverter is proposed for multi-input application. The proposed front end converter with only two controllable switches integrates two different renewable energy sources, resulting into a advantageous compact structure and low conduction losses. The ZCS turn off is achieved in both the controllable switches with proposed modulation scheme. The converter maintains ZCS turn off under a wide load as well as input voltage variations by employing frequency modulation along with variable duty ratio technique. Simple structure, soft switching, high gain and automatic load regulation makes the converter structure novel for simultaneous power management in multi-input renewable energy applications. Converter operation and design guide lines have been outlined. A laboratory prototype of the proposed converter is developed and tested at 300-Watt power level. Simulations and experimental results demonstrate the robust performance under load as well as input source voltage variationswitches with proposed modulation scheme. The converter maintains ZCS turn off under a wide load as well as input voltage variations by employing frequency modulation along with variable duty ratio technique. Simple structure, soft switching, high gain and automatic load regulation makes the converter novel for simultaneous power management in multi-input renewable energy applications. Converter operation and design guide lines have been outlined. A laboratory prototype of the proposed converter is developed and tested at 300 Watt power level. Simulations and experimental results demonstrate the robust performance under load as well as input source voltage variation

4 January 2008 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
HSH. M. Suryawanshi
H. M. Suryawanshi
MRM. R. Ramteke
M. R. Ramteke
KTK. L. Thakre
K. L. Thakre
VBV. B. Borghate
V. B. Borghate
In this paper, a three-phase ac-dc converter using three single-phase pulse width modulated active clamped, zero-voltage-switched boost converter in modular approach is presented. The active clamp technique is used for zero-voltage-switching of the main and auxiliary switches. The operating modes, analysis, and design considerations for the proposed converter are explained. To evaluate the performance of the proposed converter, finally simulation and experimental results for a 500-V, 1.5-kW prototype converter are presented. The proposed converter operates at almost unity power factor with reduced output filter size. The output voltage is regulated without affecting zero-voltage-switching, even under unbalanced three-phase input voltages.

7 May 2020 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
KKKoteswara Rao Kothapalli
Koteswara Rao Kothapalli
MRManoj R. Raju Ramteke
Manoj R. Raju Ramteke
HSHiralal Murlidhar Suryawanshi
Hiralal Murlidhar Suryawanshi
NRNaresh Kumar Reddi
Naresh Kumar Reddi
KBKALAHASTHI BABU
KALAHASTHI BABU
A high gain non-isolated dc—dc converter is proposed for the distributed generation systems. High voltage gain is achieved by integrating different methods with reduced duty ratio. Inductive voltage spikes across MOSFETs are alleviated and stress is reduced with inclusion of a passive-clamp circuit. Thus, lower voltage rating (small Rds(ON)) active devices can be adopted. Using this clamp, zero - voltage switching (ZVS) over wide load range is achieved for both the MOSFETs. In addition, leakage-energy of the coupled inductor is recycled without use of auxiliary witch and thus, the gain get further improved. Zero - current switching (ZCS) is obtained for all the diodes using quasi-resonance principle, which diminish voltage spikes across the diode caused by the parasitic ringing between leakage inductance and diode's stray capacitance. Therefore, snubbers are not necessary to protect the diodes and to mitigate reverse-recovery losses. Overall efficiency improves because of lower switching and conduction losses of the semiconductor devices. A 600—W prototype working at 75 kHz is built in the laboratory to verify the performance. The peak efficiency is nearly 96.5% and is above 95% for wide load range.

7 February 2017 in IEEE Transactions on Industrial Informatics
Verified
Journal Article
Closed access
ASAmardeep B. Shitole
Amardeep B. Shitole
HSHiralal M. Suryawanshi
Hiralal M. Suryawanshi
GTGirish G. Talapur
Girish G. Talapur
SSShelas Sathyan
Shelas Sathyan
MBMakarand S. Ballal
Makarand S. Ballal
MCMadhuri A. Chaudhari
Madhuri A. Chaudhari
This paper presents real-time implementation of a grid interfaced distributed generation (DG) system with modified current control loop using three phase amplitude adaptive notch filter (AANF) based synchronization tool. A grid current feedback based modified dq-current control technique for interfacing inverter is developed in order to achieve constant loading on the grid, transient-free operation, and power factor improvement close to unity power factor (UPF) of the utility grid during sudden load variations. This technique does not require separate calculation of reference reactive component and harmonics component of currents hence reduces control circuit complexity. In addition, it requires only three voltage and three current sensors. Three phase AANF is developed and is used for online extraction of utility voltage phase angle to generate synchronized reference current signals for interfacing inverter. AANF is used because of its adjustable accuracy and amplitude adaptability even under unbalanced voltage sag and swell, frequency variation, and distorted grid conditions. Fast and accurate behavior of three phase AANF improves the dynamic response of entire DG system control performance for sudden load variations. The dynamic behavior of the proposed grid interfaced DG system is experimentally evaluated in maintaining constant loading on grid, transient-free operation, and power factor improvement close to UPF operation of the utility grid, by compensating total reactive power and harmonic current demanded by variable linear as well as nonlinear load.

21 October 2020 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
KKKoteswara Rao Kothapalli
Koteswara Rao Kothapalli
MRManoj R. Raju Ramteke
Manoj R. Raju Ramteke
HSHiralal Murlidhar Suryawanshi
Hiralal Murlidhar Suryawanshi
NRNaresh Kumar Reddi
Naresh Kumar Reddi
KBKALAHASTHI BABU
KALAHASTHI BABU
A soft-switched modular non-isolated converter is proposed for distributed generation systems. By integrating flyback energy delivering circuit to the interleaved boost converter, ultra-high voltage gain and high efficiency are achieved with reduced duty ratio. Cockcroft-Walton(CW) based multiplier cell extensively reduces voltage stress on the active switches. Voltage spikes across MOSFETs caused by leakage inductance and interconnection of primary-secondary windings are alleviated by adjoining the active switch based auxiliary circuit. Thus, low voltage rating switches(small Rds(ON)) are employed. Further, the clamp circuit realizes wide-load-range ZVS turn-on and, reduced falling current magnitudes ensures low turn-off losses for all the MOSFTETs. Also, leakage-energy is recycled to the load. Indeed, leakage-energy effectively limits the rate of fall-current(dif/dt) through power diodes and alleviates the reverse-recovery problem by turning-off them with zero-current switching (ZCS). Further, during turn-on, ZVS is achieved for all the diodes. Thus, voltage spikes across the diodes are suppressed without needing any snubber. Minimized voltage stresses, lowered on-state and switching losses of the semiconductor devices, altogether, improves the efficiency. A 600W prototype working at 100 kHz is developed in the laboratory to validate the design analysis. Measured efficiency at rated-load is 95.81% and maximum efficiency is 96.65%.

21 September 2022 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
KKKoteswara Rao Kothapalli
Koteswara Rao Kothapalli
MRManoj R. Ramteke
Manoj R. Ramteke
HSHiralal Murlidhar Suryawanshi
Hiralal Murlidhar Suryawanshi
A soft-switched isolated bidirectional dc–dc converter is proposed for distributed generation systems. Dual coupled inductor-based flyback energy conversion circuit achieves high-voltage step-up/down ratio and high efficiency at lowered duty cycle and, attributes the galvanic isolation. Active switch-based capacitor multiplier cell appreciably reduces voltage stresses on low-voltage (LV) and high-voltage (HV) stage mosfets , thereby allowing LV rating devices (small $R_{ds(ON)}$ ). Active-voltage-clamping type circuit extensively suppresses the voltage spikes across LV-switches caused by leakage inductance. Indeed, this clamp circuitry is formed without any additional switches/diodes, thus, reduces clamp device count. By availing of quasi-resonance, thus, without needing the HV stage snubber, switching voltage spikes are substantially alleviated. Furthermore, this clamp along with quasi-resonance achieves zero-voltage (ZVS) and zero-current (ZCS) switching, over wide-load range, for all switches in both step-up and step-down operations. Reduced voltage stresses, minimized clamp device count, diminished conduction losses, and bidirectional soft-switching performance collectively enhances the efficiency. A 600-W laboratory built set-up working at 75 kHz verifies the viability of the design concept. Measured peak efficiencies in boost and buck stages are 96.65% and 96.58%, respectively.