4 April 2018 in Eastern-European Journal of Enterprise Technologies
We have studied a traction drive based on the synchronous motor with excitation from permanent magnets for its electrical losses. A simulation model of the traction drive is synthesized, which employs the algorithm of a space-vector PWM. A special feature of the model is the application of parameters of actual IGBT-transistors and the possibility for obtaining instantaneous values of electric losses in transistors and snubbers of the inverter under different modes of operation. We have devised a procedure for calculating electric losses in the traction engine based on the shape of phase currents, geometrical and electrical parameters of the engine. Simulation of the traction drive and calculation of losses in the traction engine is integrated, which makes it possible to account for the impact of the inverter and engine on each other.We have simulated work of the reducer-free traction drive based on a synchronous motor with excitation from permanent magnets with a capacity of 80 kW. The dependences were constructed for losses in the traction inverter and engine on the clock frequency of a space-vector PWM and motion speed.The proposed procedure makes it possible to quantify the magnitude of electric losses in the traction drive elements depending on the types of transistors applied, clock frequency of the inverter, and parameters of the engine. This enables the optimization of the traction drive for the criterion of maximum performance efficiency, as well as thermal calculation of the elements of the drive.
30 June 2022 in Collection of scientific works of the State University of Infrastructure and Technologies series "Transport Systems and Technologies"
The main technical parameters of the locomotive for quarry railway transport have been evaluated. The design parameters of the locomotive have been determined and it is established that the tangential power is 6700 kW, and the traction force for the design mode is 1300 kN. The calculations of the traction characteristics of the locomotive have been performed. The procedure for determining the parameters of the locomotive operating modes during train tasks performing has been proposed, which is based on the processing of the results of traction task solving on the section of the track. It has been established that for the test section of the track a significant part of the time in the traction mode the locomotive operates with a load of 10… 25% of the nominal, therefore it has been proposed to implement the mode of movement with disconnection of traction motors. The use of an onboard energy storage system, which allows the accumulation of energy during electrodynamics braking has been proposed. The generalized scheme of traction system which allows realizing ways of increase of energy efficiency a rolling stock has been offered.
28 June 2023 in Collection of scientific works of the State University of Infrastructure and Technologies series "Transport Systems and Technologies"
Виконано огляд сучасних напрямів оновлення маневрових локомотивів, які засновані на застуванні бортових накопичувачів енергії, багатодизельних силових енергетичних установок, енергетичних установок на основі водневих джерел енергії. Показано необхідність врахування умов експлуатації маневрового тепловоза при виборі варіанту оновлення. Розглянуто режими експлуатації маневрових тепловозів при виконанні маневрових операцій на вантажній станції Козятин-І протягом трьох змін. Шляхом аналізу даних бортової системи БІС-Р та опрацювання маршрутних листів визначено параметри експлуатаційних режимів. Виконано розрахунки показників використання потужності дизельного двигуна, за якими встановлено, що повноту використання встановленої потужності дизель-генератора складає 7,5…8,4%, а максимальна потужність дизеля, яка зафіксована у досліджуваних умовах експлуатації, складає близько 50%. Тривалість роботи з тягових навантаженням складає 49,5…68,8% часу зміни. Найбільш тривалими – 55…60% загальної тривалості роботи під тягою – є режими з потужністю 0…50 кВт. Тривалість роботи без навантаження складає 18,1…36,9% тривалості зміни. Виконувана маневрова робота пов’язана з формуванням і розформуванням составів, у тому числі з використанням сортувальної гірки, внаслідок чого тягова передача потужності працює з низьким коефіцієнтом корисної дії. Для зниження споживання паливно-енергетичних ресурсів при виконанні маневрової роботи необхідно оновлення парку локомотивів для маневрової роботи, характеристики яких адаптовані до режимів експлуатації.
18 June 2024 in Collection of scientific works of the State University of Infrastructure and Technologies series "Transport Systems and Technologies"
The ways of updating the rolling stock of open-pit railways have been considered and the main methods of using the energy storage on the locomotive for open-pit railways have been determined. A mathematical model has been developed, which includes a model of train movement along the railway section and during maneuvering and a model of energy processes in the traction system with onboard energy storage. Simulations were performed in a cycle that included movement from the crushing plant to the transshipment point with empty dump trucks, maneuvering during loading, movement from the crushing plant to the transshipment point with loaded dump trucks, and maneuvering during unloading. The simulation took into account the limitation of power consumption at the level of 4000 kW. The parameters of the energy storage device were determined, for which Toshiba SCiB 20Ah-HP cells were selected. The power of the energy storage is 3600 kW, and the energy capacity is 414 kWh. The use of modules for the formation of an energy storage device is proposed. It was determined that the energy consumption per work cycle with the selected energy exchange algorithm taking into account electrodynamic braking is about 200 kWh, and the charge reduction per drive cycle is 36%. The service life of the energy storage with the selected cells is estimated at 8 years.
1 August 2026 in Engineering Research Express
The paper examines the application of a hybrid power plant to locomotives performing shunting and hauling operations on quarry railways. The implementation of hybrid traction systems contributes to a reduction in diesel fuel consumption, thereby lowering CO 2 emissions and decreasing overall fuel and energy costs. The study focuses on a quarry railway line used to transport iron ore from an open-pit mine to a processing plant. A mathematical model was developed to determine the operating parameters under various locomotive operating modes. The simulation studies were carried out for train movements with both empty and loaded dump cars. The results show that the use of a hybrid power plant reduces fuel consumption during the loaded half-trip by 20.6%–30.8%, depending on the power rating of the diesel generator and the onboard energy storage system. During the empty half-trip, fuel consumption can be reduced by more than 50%. It was determined that the optimal power rating of the diesel generator is 800 kW. The minimum required power rating of the onboard energy storage system is also 800 kW. Although increasing the power rating of the energy storage system provides additional reductions in diesel fuel consumption, it results in its increased weight, larger overall dimensions, and higher cost.
13 June 2025 in NTU "KhPI" Bulletin: Power and heat engineering processes and equipment
The article considers the use of energy storage in motor-car rolling stock. The article analyses the rolling stock of European and Japanese manufacturers, which uses energy storage to provide power supply when moving through non-electrified areas. The types of energy storage devices used in motor-car rolling stock are considered, the use of energy storage is proposed, and the parameters of the energy storage device for autonomous movement of a motor-car train between the stations Merchyk and Bohodukhiv, where the railway section is not electrified, are determined. By solving traction problems, it is determined that the total energy consumption when driving on this section and in the opposite direction is 175 kWh. It is proposed to use LTO cells in energy storage devices, which will ensure their long service life. The use of energy storage devices on motor-car rolling stock will improve the quality of passenger service, reduce operating costs, and reduce environmental impact.