The method of improving a two-section mainline diesel locomotive by using energy storage in the traction system is considered. A mathematical model was developed to study the movement of a diesel locomotive based on the recommendations and provisions of the theory of locomotive traction. For this purpose, the movement of a diesel locomotive as part of a train along a given section of a track was studied. It was determined that the use of an energy storage device on a diesel locomotive will allow up to 64% of the energy spent on train traction to accumulate. The use of energy storage in the accumulator during electrodynamic braking ensured a reduction in fuel consumption by about 50%, regardless of the options for equipping the traction system of the diesel locomotive with an energy accumulator. It is established that regardless of the options for equipping the traction system of the diesel locomotive with an energy storage device, the indicators characterizing the degree of use of the diesel engine do not change. These research results can be used in works devoted to the improvement of the control system of energy exchange between the accumulator and traction engines of diesel locomotives.
An analysis of the operating conditions of the traction drives of an electric rolling stock with asynchronous traction motors was conducted. In the process of operation, the electric traction drive with both direct torque control and vector control was found to possibly experience unstable modes, both in terms of power supply and load. The models of electric locomotive traction drives with asynchronous electric motors with either vector or direct torque control were adapted to account for the possible presence of the aforementioned operational factors. As a result of the modeling, the starting characteristics of the electric traction drives with different control systems were obtained both in the absence and in the presence of power supply and load disturbances. The following cases were investigated for the drive with vector and direct torque control in the absence of power supply and torque disturbances: drive output at the rated speed of rotation of the electric motor shaft; 10% reduction in the rated speed; 10% increase in the rated speed. The comparison of the results obtained has demonstrated that, at lower than nominal frequencies, the electric traction drive with direct torque control has higher accuracy in its regulation of the rotational speed and torque, lower power consumption from the power supply, lower torque overshooting, but a higher level of torque pulsations than the electric traction drive with vector control. Meanwhile, at higher than nominal frequencies, the vector control has higher accuracy in its regulation of the speed, lower torque overshooting, shorter duration of transient processes, and lower torque pulsations than the direct torque control. Moreover, as a result of the investigations, the traction drive with direct torque control has been found to be more resistant to power supply and load disturbances. The results of this work are applicable to the investigation of the influence of electric traction drive control methods on the energy efficiency of the traction drive of an electric locomotive with an alternating current (AC).
Operation modes of rolling stock at mining enterprises are considered and analyzed. The justification of the need to replace it with a modern specialized electric locomotive for quarry railway transport, equipped with an asynchronous traction electric drive and an on-board energy storage system, is presented. The determination of the parameters and structure of the on-board energy storage system, based on the condition of power compensation with limited power consumption from the traction network and ensuring the autonomous movement of the electric locomotive, is considered. This study was carried out by modeling the processes of energy exchange in the traction system of an electric locomotive. The use of lithium cells and supercapacitors in energy storage is considered. Variants of the hybridization of energy storage were studied from the standpoint of minimizing the weight, size, and cost indicators. It was established that reducing the mass of the energy storage device, which includes lithium cells and supercapacitors, leads to an increase in the cost of one kilowatt-hour of energy storage capacity, which reduces the attractiveness of capital expenditures for the creation of such an energy storage device. Hybridization of the energy storage device by combining lithium cells of different types practically does not improve its weight, size, and cost indicators. The recommended option is a storage capacity of energy based on LTO elements, for which it is necessary to select elements in order to minimize weight, size, and cost indicators.
One of the assumptions made during the modernization process of diesel shunting locomotives is the replacement of a diesel traction motor with a DC generator with an electric asynchronous traction motor. The article aimed to develop a method of selecting energy-efficient parameters of an asynchronous electric traction motor for diesel shunting locomotives, which will ensure that its operating energy efficiency will be as high as possible. The method was verified on the example of a locomotive series ChME3 (ЧMЭ3, ČME3, ČKD S200). It has been found that using a traction asynchronous electric drive on a ChME3 locomotive, its efficiency increases in comparison with DC electric motors by 3–5% under the long-term operation modes and by 7–10% during locomotive operation with traction at the adhesion limit. Using a new traction gearbox with a higher gear ratio expands the speed range in which the asynchronous traction drive operates with a high-efficiency factor. It is effective to use a traction asynchronous electric drive to modernize ChME3 diesel locomotives in case of their use under the modes requiring the implementation of maximum traction forces at low speeds. A further increase in the efficiency of the traction asynchronous electric drive is possible based on the optimal design of the wheel-motor unit and the asynchronous traction electric drive.
28 April 2023 in Engineering Science and Technology, an International Journal
The operation of a direct torque control (DTC) system for induction motors with the possible presence of unbalanced modes in the motor windings is studied. It is shown that in the presence of asymmetric modes in the motor windings, the classical DTC algorithm becomes unstable. It is proposed to improve the DTC by taking into account the unbalance of the active resistances of the motor stator windings when determining the DTC parameters. This will make it possible to study electrodynamic processes in DTC with the possible presence of asymmetric modes in the windings of induction motor.