Stefano Facchinetti

Stefano Facchinetti

Auto-generated profile, based on publicly available information

Stefano Facchinetti

MSH Division, ST Microelectronics, Cornaredo (MI) Italy

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 November 2017 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
PMPaolo Minotti
Paolo Minotti
SDStefano Dellea
Stefano Dellea
GMGiorgio Mussi
Giorgio Mussi
ABAndrea Bonfanti
Andrea Bonfanti
SFStefano Facchinetti
Stefano Facchinetti
GLGiacomo Langfelder
Giacomo Langfelder
This paper reports the developments toward an integrated, tri-axial, frequency-modulated, consumergrade, and microelectromechanical system (MEMS) gyroscope. A custom low-power (160 μA), low-phase-noise integrated circuit is designed specifically for frequencymodulated operation. Both yawand pitch-rate sensing systems are demonstrated by coupling the circuit with two novel micromachined structures fabricated with a 24-μmthick industrial process. In operation, both gyroscopes show a repeatable and stable scale factor, with less than 0.55% of part-to-part variability, obtained with no any calibration, and 35 ppm/°C of variability over a 25-70 °C temperature range.

15 November 2018 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
MLMauro Leoncini
Mauro Leoncini
MBMarco Bestetti
Marco Bestetti
ABAndrea Bonfanti
Andrea Bonfanti
SFStefano Facchinetti
Stefano Facchinetti
PMPaolo Minotti
Paolo Minotti
GLGiacomo Langfelder
Giacomo Langfelder
A complete system of a frequency modulated (FM) gyroscope with digital output for future low-power, high-stability and wide full-scale applications is presented. The system includes the microelectromechanical transducer, two analog oscillators, two mixed-signal frequency to digital converters and a fundamental mixed-signal block for the real-time extraction and digitization of the demodulation phase reference. With an overall consumption of 406 μA, the system has a 90 dB dynamic range on a 50 Hz bandwidth, with a 5 °/hr stability after 20-minute observation interval, and a scale-factor drift coefficient of 20 ppm/K only.

21 August 2014 in IEEE Transactions on Nuclear Science
Verified
Journal Article
Open access
CFCarlo Fiorini
Carlo Fiorini
BNB. Nasri
B. Nasri
SFS. Facchinetti
S. Facchinetti
LBL. Bombelli
L. Bombelli
PFP. Fischer
P. Fischer
MPM. Porro
M. Porro
New X-ray pixel detectors are required to cope with the demanding requirements from XFEL sources, in terms of high speed and high dynamic range. Such detectors have to provide low electronics noise to allow single photon detection at low signal intensities. At high photons intensity, a signal compression technique may be introduced to allow the detection system to cope with the required dynamic range. In this work, we propose a very simple front-end (FE) solution based on an input PMOS transistor placed on the CMOS readout chip connected to the pixel detector. The FE is optimized for low-noise readout of X-ray photons at low intensities. A gain compression when the signal intensity increases is obtained by operating the PMOSFET in the triode regime thanks to a resistor placed between the transistor and the current-readout filter. The larger is the transistor signal, the larger is the voltage drop on the resistor which pushes the transistor to operate more in triode regime at lower gain, producing a compression in the overall FE response. The FE working principle and the first experimental results obtained with a first prototype realized in the 130 nm IBM technology are presented.

1 October 2011
Verified
Conference Paper
Closed access
SFStefano Facchinetti
Stefano Facchinetti
LBLuca Bombelli
Luca Bombelli
ACAndrea Castoldi
Andrea Castoldi
CFCarlo Fiorini
Carlo Fiorini
CGChiara Guazzoni
Chiara Guazzoni
FEFlorian Erdinger
Florian Erdinger
A high speed focal plane system and a novel non linear DEPFET detector are under development to comply with the European X-ray Free Electron Laser (XFEL) requirements. The facility is under construction in the Hamburg area (Germany) and will be able to deliver ultra short, high intensity X-ray pulses 220ns apart and grouped in macro bunches with a repetition rate of 10Hz. DEPFETs have been chosen since they can provide excellent energy resolution and high speed readout. Full parallel readout is required, with every channel comprising analog filtering, data conversion and memory storage. Here we present results for the first prototype of the analog front end stage, that implements a current readout approach. The circuit is based on the Flip Capacitor Filter technique and was realized in 130nm 1.2V CMOS technology from IBM.

8 August 2017 in Proceedings
Verified
Conference Paper
Open access
PDF file
Valentina ZegaValentina Zega
Valentina Zega
PMPaolo Minotti
Paolo Minotti
GMGiorgio Mussi
Giorgio Mussi
ATAlessandro Tocchio
Alessandro Tocchio
LFLuca Falorni
Luca Falorni
Alberto CoriglianoAlberto Corigliano
Alberto Corigliano
In this work, the mechanical design and the experimental validation of a micro-electromechanical frequency-modulated (FM) pitch gyroscope are presented. The proposed device is fabricated through the ThELMA © surface micromachining process of STMicroelectronics and it represents, to the authors’ knowledge, the first small-footprint (690 µm × 946 µm) prototype of FM gyroscope able to measure an in-plane angular rate. The measured scale factor, defined as the mean angular gain, equals 0.973 Hz/Hz, in close agreement with theoretical predictions. It depends only on the mass distribution in the mechanical structure and is, consequently, not influenced by environmental fluctuations.

1 October 2011
Verified
Conference Paper
Closed access
MUMichela Uslenghi
Michela Uslenghi
MFMichele Fiori
Michele Fiori
CFCarlo Fiorini
Carlo Fiorini
LBLuca Bombelli
Luca Bombelli
SFStefano Facchinetti
Stefano Facchinetti
SISalvatore Incorvaia
Salvatore Incorvaia
It is well known that the use of electronics components in space exposes them to ionizing radiation, which can damage the devices. A careful characterization of the sensitivity to radiation-induced damages is thus of capital importance for the critical devices. VELA (VLSI Electronic for Astronomy) is an ASIC developed at the Politecnico of Milano in collaboration with Max-Planck-Institut Semiconductor Laboratory, in 0.35 μm AMS CMOS technology, which implements the readout front-end electronics for an innovative x-ray detector, the DEPMOS-based APS, Active Pixel Sensor. This sensor is capable of providing an excellent energy resolution even at very high speed readout. The absence of the charge transfer mechanism, makes APS sensors very attractive for harsh radiation space environments. The behavior of the front-end electronics under irradiation is then a critical issue. We present a study of the Single Event Effects induced by heavy ions in VELA, in view of a possible utilization in new generation satellites for X-ray astronomy. The tests have been carried out at the SIRAD facility of the Laboratori Nazionali INFN di Legnaro. In this paper we describe the measurements and the experimental setup, designed and realized ad hoc to monitor Single Event Latch-up (SEL) and Single Event Upset (SEU).