Tingyu Zhu

Tingyu Zhu

Auto-generated profile, based on publicly available information

Tingyu Zhu

Graduate School of Engineering, The University of Tokyo, Tokyo, Japan

Research Focus & Metrics

Academic Career Length

1Year (2026-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 March 2026 in AIP Advances
Verified
Journal Article
Open access
PDF file
KKKanta Komuro
Kanta Komuro
MFMotofumi Fushimi
Motofumi Fushimi
YKYuta Kainuma
Yuta Kainuma
TZTingyu Zhu
Tingyu Zhu
SFSeiko Funatani
Seiko Funatani
MSMasaki Sekino
Masaki Sekino
The aim of this study was to evaluate the effectiveness of optical stimulation in optogenetically modified rats for magnetoencephalographic (MEG) measurements in small animals. Inducing such responses through external stimulation and recording them with MEG is important for elucidating the fundamental brain mechanisms. Various stimulation methods, including electrical stimulation, have been proposed, but obtaining somatosensory responses in small animals with MEG remains difficult due to mechanical noise and electromagnetic interference. In this work, we employed optical stimulation of whiskers in channelrhodopsin-2 (ChR2)-expressing rats. Optical stimulation provides precise control, localized delivery via optical fibers, and nonmagnetic compatibility, making it well suited for MEG measurements. We used optically pumped magnetometers (OPMs), which offer the advantage of operating without a helium-based cryogenic cooling system, unlike conventional superconducting quantum interference device SQUID sensors. A custom jig was developed to construct a gradiometric measurement system with five OPM sensors inside a magnetic shield room. Whiskers of ChR2 rats were stimulated with blue light (473 nm), and brain magnetic fields were recorded at 64 locations with 6.25 mm spacing. Averaged responses revealed somatosensory-evoked magnetic fields of several hundred fT at 50 ms latency, yielding reliable dipolar field maps over a 5 × 5 cm2 area.

10 June 2026 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Open access
XCXinyu Cao
Xinyu Cao
TZTingyu Zhu
Tingyu Zhu
SCShinichi Chikaki
Shinichi Chikaki
MFMotofumi Fushimi
Motofumi Fushimi
MSMasaki Sekino
Masaki Sekino
Real-time active magnetic field compensation is essential for mobile precision measurements inside magnetically shielded rooms with inhomogeneous residual fields, particularly for applications such as moving magnetoencephalography (MEG) using optically pumped magnetometers (OPMs). Conventional field evaluation based on the Biot–Savart integration is computationally demanding for sensor motion. This paper presents a high-speed active magnetic field compensation method using a precomputed multipole expansion model of coil-generated fields, enabling rapid adaptation to arbitrary sensor motion without numerically re-evaluating the field. The system, comprising an eight-coil array mounted on a 50-cm cubic frame, achieved a feedback-control update time below 10 ms and maintained OPM operation during 360° rotations and 28 cm translations (56% of the frame side length). A shielding factor of 20.4 dB was achieved under stationary conditions, and at least 10.3 dB was maintained during continuous motion. Experimental validation using an MEG setup demonstrated reliable detection of the auditory evoked response component under both stationary and dynamic conditions, verifying the robust suppression of motion-induced field fluctuations. The proposed multipole-expansion-based real-time compensation provides a computationally efficient and motion-adaptive approach for magnetic field stabilization and offers a scalable solution for a wide range of mobile precision measurement systems.