Motofumi Fushimi

Motofumi Fushimi

Auto-generated profile, based on publicly available information

Motofumi Fushimi

Graduate School of Engineering, The University of Tokyo, Tokyo, Japan

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
5 June 2024 in Physical Review Applied
Verified
Journal Article
Closed access
PDF file
NSN. Sekiguchi
N. Sekiguchi
MFM. Fushimi
M. Fushimi
AYA. Yoshimura
A. Yoshimura
CSC. Shinei
C. Shinei
MMM. Miyakawa
M. Miyakawa
TIT. Iwasaki
T. Iwasaki
We present a sensitive diamond quantum sensor with a magnetic field sensitivity of 9.4±0.1pT/Hz in a near-dc frequency range of 5 to 100 Hz. This sensor is based on the continuous-wave optically detected magnetic resonance of an ensemble of nitrogen-vacancy centers along the [111] direction in a diamond (111) single crystal. The long T2∗∼2μs in our diamond and the reduced intensity noise in laser-induced fluorescence result in remarkable sensitivity among diamond quantum sensors. Based on an Allan-deviation analysis, we demonstrate that a subpicotesla field of 0.3 pT is detectable by interrogating the magnetic field for a few thousand seconds. The sensor head is compatible with various practical applications and allows a minimum measurement distance of about 1 mm from the sensing region. The proposed sensor facilitates the practical application of diamond quantum sensors. The sensitivity presented is realized without a magnetic flux concentrator, so that a sensitivity of tens of fT/Hz can be achievable by using a flux concentrator.

30 December 2021 in IEEE Transactions on Medical Imaging
Verified
Journal Article
Closed access
NENaohiro Eda
Naohiro Eda
MFMotofumi Fushimi
Motofumi Fushimi
KHKeisuke Hasegawa
Keisuke Hasegawa
TNTakaaki Nara
Takaaki Nara
Magnetic resonance electrical properties tomography (MREPT) noninvasively reconstructs high-resolution electrical property (EP) maps using MRI scanners and is useful for diagnosing cancerous tissues. However, conventional MREPT methods have limitations: sensitivity to noise in the numerical Laplacian operation, difficulty in reconstructing three-dimensional (3D) EPs and convergence not guaranteed in the iterative process. We propose a novel, iterative 3D reconstruction MREPT method without a numerical Laplacian operation. We derive an integral representation of the electric field using its Helmholtz decomposition with Maxwell’s equations, under the assumption that the EPs are known on the boundary of the region of interest with the approximation that the unmeasurable magnetic field components are zero. Then, we solve the simultaneous equations composed of the integral representation and Ampere’s law using a convex projection algorithm whose convergence is theoretically guaranteed. The efficacy of the proposed method was validated through numerical simulations and a phantom experiment. The results showed that this method is effective in reconstructing 3D EPs and is robust to noise. It was also shown that our proposed method with the unmeasurable component $H^{-}$ enhances the accuracy of the EPs in a background and that with all the components of the magnetic field reduces the artifacts at the center of the slices except when all the components of the electric field are close to zero.

12 May 2025 in Applied Physics Letters
Verified
Journal Article
Closed access
NSNaota Sekiguchi
Naota Sekiguchi
YKYuta Kainuma
Yuta Kainuma
MFMotofumi Fushimi
Motofumi Fushimi
CSChikara Shinei
Chikara Shinei
MMMasashi Miyakawa
Masashi Miyakawa
TITakayuki Iwasaki
Takayuki Iwasaki
We employ a dry-type phantom to evaluate the performance of a diamond quantum magnetometer with a high sensitivity of about 6 pT/Hz from the viewpoint of practical measurement in biomagnetic sensing. The dry phantom is supposed to represent an equivalent current dipole (ECD) generated by brain activity, emulating an encephalomagnetic field. The spatial resolution of the magnetometer is evaluated to be sufficiently higher than the length of the variation in the encephalomagnetic field distribution. The minimum detectable ECD moment is evaluated to be 0.2 nA m by averaging about 8000 measurements for a standoff distance of 2.4 mm from the ECD. We also discuss the feasibility of detecting an ECD in the measurement of an encephalomagnetic field in humans. We conclude that it is feasible to detect an encephalomagnetic field from a shallow cortex area such as the primary somatosensory cortex.

28 May 2024 in IEEE Transactions on Magnetics
Verified
Journal Article
Closed access
AIAnna Iino
Anna Iino
MFMotofumi Fushimi
Motofumi Fushimi
JTJunichi Tabata
Junichi Tabata
TKTakuma Kikuchi
Takuma Kikuchi
YSYutaro Soejima
Yutaro Soejima
MSMasaki Sekino
Masaki Sekino
The stimulation of deeper brain regions with transcranial magnetic stimulation (TMS) is a promising treatment for depression with higher remission rates. The focality of the stimulation area is essential to reduce the risk of side effects; however, there is a physical tradeoff between depth and focality. Because existent studies have searched for depth by iteratively designing a coil and then calculating the electric field in the brain, the theoretical maximum depth has not yet been determined. In this study, we propose a methodology to derive the coil based on an inverse problem approach from an analytical description of the desired electric field in the brain. This new method has allowed us to theoretically derive the maximum depth of the electric field, which was previously only determined empirically. Based on this, we designed and built a coil that can deliver the electric field to the deepest depth. Numerical simulations of the proposed coils show that they have the highest electric field depth of any coil feasible in the existing medical field. Moreover, the balance between depth and focality was also the best of the existing coils.

1 January 2024 in AIP Advances
Verified
Journal Article
Open access
PDF file
WMWataru Matsumoto
Wataru Matsumoto
BFBoyu Feng
Boyu Feng
YTYoshiki Tamai
Yoshiki Tamai
TUTaisei Ueki
Taisei Ueki
KKKei Kamada
Kei Kamada
MSMasaki Sekino
Masaki Sekino
T2 relaxation time in magnetic resonance imaging (MRI), which is determined by magnetic dipole interactions, has been employed as a parameter for tumor detection. However, owing to the lack of MRI detection sensitivity, nuclear medicine imaging is currently the basic option for tracking low concentrations of chemical probes. Previous studies utilizing cascade radionuclides have focused on the relaxation due to electric quadrupole interactions. However, magnetic dipole interactions, which are crucial in MRI, remains to be elucidated. In this study, we determined the magnetic relaxation rate by using 111In, a cascade radionuclide used in clinical single-photon emission computed tomography (SPECT) scans. As the angle between the gamma rays from the nuclei is affected by the electrical and magnetic interactions acting on the nuclei, we measured the angular correlation ratio by using eight gadolinium gallium garnet (GAGG) multi-pixel photon counter (MPPC) 8 × 8 array detectors and extracted the magnetic relaxation rate. Consequently, we obtained a rate that increased with the Fe concentration, similar to the T2 relaxation rate, although it was influenced by the inhomogeneity of the external magnetic field. This study utilized low concentrations of the liquid-state radionuclide, which is commonly used in clinical nuclear medicine imaging scans and is expected to provide much higher sensitivity and more selective detection of tumors than conventional MRI.

1 January 2024 in AIP Advances
Verified
Journal Article
Open access
PDF file
MTMasaharu Takahashi
Masaharu Takahashi
MFMotofumi Fushimi
Motofumi Fushimi
SYShin Yabukami
Shin Yabukami
MSMasaki Sekino
Masaki Sekino
AKAkihiro Kuwahata
Akihiro Kuwahata
We propose a novel method based on an inverse problem to design a single channel radio frequency (RF) receive coil for magnetic resonance imaging (MRI) with an optimized signal-to-noise ratio (SNR) for imaging the rat kidney. We identified a dedicated curved-surface coil design for use on the rat body surface utilizing inverse problem analysis using direct current calculation and quantitatively evaluated the indicators of coil performance using alternating current calculation. The proposed coil achieved increased SNR and signal intensity responses that were respectively 1.05- and 2-fold higher than those of conventional surface coils. In the future, we will fabricate a prototype coil and perform the MRI of the rat kidney to diagnose kidney diseases.