23 December 2021 in Physical Review Applied
Currently, thermally excited magnons are being intensively investigated, owing to their potential in computing devices and thermoelectric conversion technologies. We report the detection of a thermal magnon current propagating in a magnetic insulator yttrium iron garnet under a temperature gradient using a quantum sensor: electron spins associated with nitrogen-vacancy (N-V) centers in diamond. A thermal magnon current is observed as modified Rabi-oscillation frequencies of N-V spins hosted in a beam-shaped bulk diamond that is resonantly coupled with coherent magnon propagating over a long distance. Additionally, using a nanodiamond, alteration in N-V spin-relaxation rates, depending on the applied temperature gradient, are observed under nonresonant N-V excitation conditions. The demonstration of probing a thermal magnon current mediated by coherent magnons via N-V spin states serves as a basis for creating a device platform that hybridizes spin caloritronics and spin qubits.
19 June 2024 in Advanced Quantum Technologies
This study proposes compact, highly sensitive, and stable diamond quantum sensors for a wide range of applications, including biomedical and energy electronics. For enhanced sensitivity and alignment precision within the objective field, a high‐quality, (111)‐oriented 12 C‐enriched chemical vapor deposition (CVD) diamond, featuring a nitrogen‐vacancy (NV) axis in the (111) direction, is employed as the sensor. To increase the fluorescence collection efficiency, the laser beam is irradiated from the side surface of the CVD diamond, and fluorescence is detected using a compound parabolic concentrator (CPC) lens. The floor noise level of the magnetic field signal is 44 pT/Hz 0.5 . An Allan deviation of 1.2 pT over 1000 s of averaging demonstrates stability. This is attributable to the integration of a balancing circuit to cancel out laser noise, alongside mechanisms to compensate for temperature fluctuations and a copper housing to shield against electromagnetic field noise.
28 December 2021 in Journal of Applied Physics
The nitrogen-vacancy (NV) centers in diamond have been applied to scanning magnetometer probes combined with atomic force microscopy (AFM) to demonstrate nanometer-scale magnetic sensing and imaging. However, the scanning diamond NV center probe fabrication requires complicated processes including electron-beam lithography and photolithography. In this study, we introduce an alternative method to fabricate a scanning NV probe using laser cutting and focused ion beam (FIB) milling from a bulk diamond hosting an ensemble of NV centers. A few tens of micrometer-sized diamond pieces, cut by laser processing, were attached to the probe end of a quartz tuning-fork-based AFM. Then, it was fabricated into a few-micrometer-sized diamond NV center probe by using a donut-shaped milling pattern in the FIB processing to avoid damage to the diamond probe surface to degrade the NV− charged state at the tip apex. By using a home-built scanning NV magnetometer probe microscopy setup, an optically detected magnetic resonance was measured to detect stray magnetic fields demonstrating the imaging of a magnetic structure of approximately 5-μm periodicity from a magnetic tape. This study offers a method with a higher degree of probe-shape control for scanning NV probe that will broaden its application capabilities.
12 May 2025 in Applied Physics Letters
We employ a dry-type phantom to evaluate the performance of a diamond quantum magnetometer with a high sensitivity of about 6 pT/Hz from the viewpoint of practical measurement in biomagnetic sensing. The dry phantom is supposed to represent an equivalent current dipole (ECD) generated by brain activity, emulating an encephalomagnetic field. The spatial resolution of the magnetometer is evaluated to be sufficiently higher than the length of the variation in the encephalomagnetic field distribution. The minimum detectable ECD moment is evaluated to be 0.2 nA m by averaging about 8000 measurements for a standoff distance of 2.4 mm from the ECD. We also discuss the feasibility of detecting an ECD in the measurement of an encephalomagnetic field in humans. We conclude that it is feasible to detect an encephalomagnetic field from a shallow cortex area such as the primary somatosensory cortex.
1 June 2022 in APL Photonics
The current generation of quantum sensing technologies using color centers in diamond crystals is primarily based on the principle that the resonant microwave frequency of the luminescence between quantum levels of the nitrogen-vacancy (NV) center varies with temperature and electric and magnetic fields. This principle enables us to measure, for instance, magnetic and electric fields, as well as local temperature with nanometer resolution in conjunction with a scanning probe microscope (SPM). However, the time resolution of conventional quantum sensing technologies has been limited to microseconds due to the limited luminescence lifetime. Here, we investigate ultrafast opto-magnetic effects in diamond crystals containing NV centers to improve the time resolution of quantum sensing to sub-picosecond time scales. The spin ensemble from diamond NV centers induces an inverse Cotton–Mouton effect (ICME) in the form of a sub-picosecond optical response in a femtosecond pump–probe measurement. The helicity and quadratic power dependence of the ICME can be interpreted as a second-order opto-magnetic effect in which ensembles of NV electron spins act as a source for the ICME. The results provide fundamental guidelines for enabling high-resolution spatial-time quantum sensing technologies when combined with SPM techniques.
1 March 2026 in AIP Advances
The aim of this study was to evaluate the effectiveness of optical stimulation in optogenetically modified rats for magnetoencephalographic (MEG) measurements in small animals. Inducing such responses through external stimulation and recording them with MEG is important for elucidating the fundamental brain mechanisms. Various stimulation methods, including electrical stimulation, have been proposed, but obtaining somatosensory responses in small animals with MEG remains difficult due to mechanical noise and electromagnetic interference. In this work, we employed optical stimulation of whiskers in channelrhodopsin-2 (ChR2)-expressing rats. Optical stimulation provides precise control, localized delivery via optical fibers, and nonmagnetic compatibility, making it well suited for MEG measurements. We used optically pumped magnetometers (OPMs), which offer the advantage of operating without a helium-based cryogenic cooling system, unlike conventional superconducting quantum interference device SQUID sensors. A custom jig was developed to construct a gradiometric measurement system with five OPM sensors inside a magnetic shield room. Whiskers of ChR2 rats were stimulated with blue light (473 nm), and brain magnetic fields were recorded at 64 locations with 6.25 mm spacing. Averaged responses revealed somatosensory-evoked magnetic fields of several hundred fT at 50 ms latency, yielding reliable dipolar field maps over a 5 × 5 cm2 area.