Jan Dostal

Jan Dostal

Auto-generated profile, based on publicly available information

Jan Dostal

Institute of Plasma Physics, Czech Academy of Sciences U Slovanky 1 2525/1a, 182 00 Prague

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 November 2019 in Physics of Plasmas
Verified
Journal Article
Closed access
LAL. Antonelli
L. Antonelli
JTJ. Trela
J. Trela
FBF. Barbato
F. Barbato
GBG. Boutoux
G. Boutoux
PNPh. Nicolaï
Ph. Nicolaï
MKM. Krus
M. Krus
We present the results of an experiment on laser-driven shock waves performed at the Prague Asterix Laser system (PALS), where the fundamental frequency of the laser (1315 nm) is used to launch a strong shock in planar geometry. The experiment aims to characterize both shock waves and hot electrons generated at intensities of ≃1016 W/cm2. It is shown that, in these interaction conditions, hydrodynamics is strongly impacted by noncollisional mechanisms, and the role of the hot electrons, generated by parametric instabilities, is essential in determining shock dynamics.

1 October 2017 in Physics of Plasmas
Verified
Journal Article
Open access
TPTadeusz Pisarczyk
Tadeusz Pisarczyk
SGSergey Yu. Gus'KOv
Sergey Yu. Gus'KOv
TCTomasz Chodukowski
Tomasz Chodukowski
RDRoman Dudzak
Roman Dudzak
PKPhilipp Korneev
Philipp Korneev
PPPawel Pisarczyk
Pawel Pisarczyk
The problem of spontaneous magnetic field generation with nanosecond laser pulses raises a series of fundamental questions, including the intrinsic magnetization mechanisms in laser-driven plasmas and the understanding of charge-discharge processes in the irradiated target. These two issues are tightly bound as the charge-discharge processes are defined by the currents, which have in turn a feedback by magnetic fields in the plasma. Using direct polaro-interferometric measurements and theoretical analysis, we show that at parameters related to the PALS laser system (1.315 μ m, 350  ps, and 1016  W/cm2), fast electrons play a decisive role in the generation of magnetic fields in the laser-driven plasma. Spatial distributions of electric currents were calculated from the measured magnetic field and plasma density distributions. The obtained results revealed the characteristics of strong currents observed in capacitor-coil magnetic generation schemes and open a new approach to fundamental studies related to magnetized plasmas.

1 February 2021 in Review of Scientific Instruments
Verified
Journal Article
Closed access
PDF file
MKMichal Krupka
Michal Krupka
SSSushil Kumar Singh
Sushil Kumar Singh
TPT. Pisarczyk
T. Pisarczyk
JDJ. Dostal
J. Dostal
MKM. Kalal
M. Kalal
Libor JuhaLibor Juha
Libor Juha
This paper describes design, development, and implementation of a multi-channel magnetic electron spectrometer for the application in laser–plasma interaction experiments carried out at the Prague Asterix Laser System. Modular design of the spectrometer allows the setup in variable configurations to evaluate the angular distribution of hot electron emission. The angular array configuration of the electron spectrometers consists of 16 channels mounted around the target. The modules incorporate a plastic electron collimator designed to suppress the secondary radiation by absorbing the wide angle scattered electrons and photons inside the collimator. The compact model of the spectrometer measures electron energies in the range from 50 keV to 1.5MeV using ferrite magnets and from 250 keV to 5MeV using stronger neodymium magnets. An extended model of the spectrometer increases the measured energy range up to 21MeV or 35MeV using ferrite or neodymium magnets, respectively. Position to energy calibration was obtained using the particle tracking simulations. The experimental results show the measured angularly resolved electron energy distribution functions from interaction with solid targets. The angular distribution of hot electron temperature, the total flux, and the maximum electron energy show a directional dependence. The measured values of these quantities increase toward the target normal. For a copper target, the average amount of measured electron flux is 1.36 × 1011, which corresponds to the total charge of about 21 nC.

1 April 2017 in Review of Scientific Instruments
Verified
Journal Article
Closed access
JDJ. Dostal
J. Dostal
RDR. Dudzak
R. Dudzak
TPT. Pisarczyk
T. Pisarczyk
MPM. Pfeifer
M. Pfeifer
JHJaroslav Huynh
Jaroslav Huynh
JUJ. Ullschmied
J. Ullschmied
A system of precise pulse synchronization between a single-shot large-scale laser exploiting an acousto-optical modulator and a femtosecond high repetition rate laser is reported in this article. This opto-electronical system has been developed for synchronization of the sub-nanosecond kJ-class iodine photodissociation laser system (Prague Asterix Laser System—PALS) with the femtosecond 25-TW Ti:sapphire (Ti:Sa) laser operating at a repetition rate 1 kHz or 10 Hz depending on the required energy level of output pulses. At 1 kHz synchronization regime, a single femtosecond pulse of duration about 45 fs and a small energy less than 1 mJ are exploited as a probe beam for irradiation of a three-frame interferometer, while at 10 Hz repetition rate a single femtosecond pulse with higher energy about 7–10 mJ is exploited as a probe beam for irradiation of a two-channel polaro-interferometer. The synchronization accuracy ±100 ps between the PALS and the Ti:Sa laser pulses has been achieved in both regimes of synchronization. The femtosecond interferograms of laser-produced plasmas obtained by the three-frame interferometer and the femtosecond polarimetric images obtained by the two-frame polaro-interferometer confirm the full usefulness and correct functionality of the proposed method of synchronization.

1 November 2018 in Physics of Plasmas
Verified
Journal Article
Closed access
PDF file
Josef KrásaJosef Krása
Josef Krása
DKD. Klír
D. Klír
KŘK. Řezáč
K. Řezáč
JCJ. Cikhardt
J. Cikhardt
MKM. Krůs
M. Krůs
JKJan Kaufman
Jan Kaufman
By the use of various experimental techniques, it is shown that the relativistic electrons, MeV protons, and deuterons are emitted from a 500-μm thick (CD2)n target exposed to Iλ2 ≈ 5 × 1016 W cm–2 μm2, which is delivered by the iodine photodissociation laser Prague Asterix Laser System. A parameter reflecting the laser-power efficiency of the proton acceleration is used for comparison of the observed maximum proton energy with data from other experiments. The number of protons and deuterons constituting the backward and forward jets is estimated. Values of maximum proton energies and electron temperatures indicate that the laser intensity should reach a relativistic level through the laser beam self-focusing. The occurrence of electron bunches in front of the irradiated target surface was identified by time resolved femtosecond interferometry. Energy distribution functions of electrons emitted in the both backward and forward directions are analysed and compared.

1 March 2024 in Physics of Plasmas
Verified
Journal Article
Open access
PDF file
CVC. Vlachos
C. Vlachos
VOV. Ospina-Bohórquez
V. Ospina-Bohórquez
PBP. W. Bradford
P. W. Bradford
GPGabriel Perez-Callejo
Gabriel Perez-Callejo
MEMichael Ehret
Michael Ehret
JSJ. J. Santos
J. J. Santos
We present measurements of magnetic fields generated in laser-driven coil targets irradiated by laser pulses of nanosecond duration, 1.053 μm wavelength, 500 J energy, and ∼1015 W/cm2 intensity, at the LULI2000 facility. Using two perpendicular probing axes, proton deflectometry is used to characterize the coil current and static charge at different times. Results reveal various deflection features that can be unambiguously linked to a looping quasi-steady current of well-understood polarity or to a static charging of the coil surface. Measured currents are broadly consistent with predictions from a laser-driven diode-current source and lumped circuit model, supporting the quasi-steady assessment of the discharges. Peak magnetic fields of ∼50 T at the center of 500-μm-diameter coils, obtained at the moderate laser intensity, open up the use of such laser-driven coil targets at facilities worldwide to study numerous phenomena in magnetized high-energy-density plasmas, and its potential applications.