Meltem Nermin Dursun

Meltem Nermin Dursun

Auto-generated profile, based on publicly available information

Meltem Nermin Dursun

IZMIR DEMOCRACY UNIVERSITY, FACULTY OF DENTISTRY

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 September 2022 in Journal of Esthetic and Restorative Dentistry
Verified
Journal Article
Closed access
MDMeltem Nermin Dursun
Meltem Nermin Dursun
EEEsra Ergin
Esra Ergin
ATAybüke uslu tekce
Aybüke uslu tekce
SEVIL GURGANSEVIL GURGAN
SEVIL GURGAN

3 July 2025 in BMC Oral Health
Verified
Journal Article
Open access
PDF file
MPMeltem Nermin Polan
Meltem Nermin Polan
SEVIL GURGANSEVIL GURGAN
SEVIL GURGAN
To evaluate the impacts of various charcoal-containing whitening toothpastes on color stability and surface roughness of a supra-nanofilled composite resin. A total of 105 disc-shaped specimens were fabricated using a supra-nano spherical-filled composite resin and immersed in a coffee solution to induce staining. Color and surface roughness were measured before (T0) and after staining process (T1). The specimens were randomly allocated into seven groups (n = 15): a negative control (Distilled water, DW), a positive control (Colgate Total 12, CT12), and five groups treated with charcoal-containing whitening toothpastes: Colgate Optic White (COW), Curaprox Black Is White (CBW), R.O.C.S. Black Edition Whitening (ROCS), Ipana 3D White (IPW), and Signal Nature Elements Charcoal (SNE). Brushing was performed using an electric toothbrush three times per day for 30s over a two-week period, followed by final color and surface roughness measurements (T2). Statistical analyses were performed using one-way ANOVA, Kruskal–Wallis, Tukey’s HSD, Tamhane’s T2, and Dunn’s tests (p < 0.05). Color alterations (ΔE00) in all groups treated with charcoal-based whitening toothpastes exceeded the clinical acceptability threshold. However, no statistically significant differences in ΔE00 were noted among these groups (p > 0.05).The SNE group exhibited significantly higher ∆b values than the COW and CBW groups (p < 0.05), while the CBW group presented considerably lower ΔL values than the COW, IPW, and SNE groups (p < 0.05). A significant increase in surface roughness ​​was detected in all groups exposed to charcoal-based whitening toothpastes (p < 0.05),with statistically significant variations observed among groups (p < 0.05). Charcoal-containing whitening toothpastes effectively reduced coffee-induced discoloration on composite resin surface while causing a significant increase in surface roughness. The toothpastes used exhibited similar effects on color change but showed variations in surface roughness among groups.

25 December 2023 in Selcuk Dental Journal
Verified
Journal Article
Closed access
AKAyşe Rençber Kızılkaya
Ayşe Rençber Kızılkaya
MDMeltem Nermin Dursun
Meltem Nermin Dursun
Objective: The aim of this study was to evaluate the effect of five different beverages and polishing on the color change of two different temporary prosthetic materials manufactured with different methods. Method: 160 (10x2 mm) disc-shaped samples were fabricated using direct (Acrytemp)(n=80) and indirect (Imident) (n=80) temporary prosthetic materials. Samples prepared using molds were divided into four groups as polished (direct/indirect material) and unpolished (direct/indirect material) (n=40 each). After initial measurement of L,a,b values using a spectrophotometer, the samples in each group were immersed in five different beverages (distilled water (DW), coffee (CF), cola (CC), sour cherry juice (CJ), red wine (RW) (n=8) and stored for 7 days. Then, the spectrophotometric measurements of the samples were repeated and the color change (ΔE00) values were calculated. Data were analyzed using a three-way-ANOVA followed by post hoc Tukey HSD test (p=0.05). Results: Greater color change was observed in the direct temporary material (p

26 October 2021 in Clinical and Experimental Health Sciences
Verified
Journal Article
Closed access
ATAybüke uslu tekce
Aybüke uslu tekce
CACansu Atalay
Cansu Atalay
MDMeltem Nermin Dursun
Meltem Nermin Dursun
AEA. Atila Ertan
A. Atila Ertan
AYA. Rüya Yazici
A. Rüya Yazici
Objective: evaluate the influence of single- or double-layer application of a universal adhesive on the bond strength to different tooth substrates. Methods: To Seventy-two extracted sound human teeth were used for the study. The teeth were divided into three groups according to tooth substrates; enamel, coronal and radicular dentin (n=24). The roots of the teeth were separated from the crowns and then abraded to obtain flat surfaces. The specimens were randomly allocated into 2 groups in accordance with application layers of universal adhesive (n=12). The universal adhesive, Adhese Universal was applied in self-etch mode as single- or double-layer (without light-curing of the first layer) to different substrates. Following the adhesive application, enamel, coronal- and radicular dentin substrates were restored with a resin composite (Tetric N-Ceram). The specimens were subjected to shear bond strength (SBS) test after storage in distilled water (37℃,24 h). Representative fractured and interface samples from each group were examined by a scanning electron microscope. The data were analyzed using two-way ANOVA(α = 0.05). Results: There was no statistically difference in SBS values between single- and double-layer applications of the tested universal adhesive on different dental substrates (p>0.05). Whilst no difference was occurred between the different dental substrates in the single-layer application (p>0.05), double-layer application on coronal dentin presented significantly higher bond strength than enamel (p

23 December 2024 in Selcuk Dental Journal
Verified
Journal Article
Open access
EMEce Meral
Ece Meral
MPMeltem Nermin Polan
Meltem Nermin Polan
AOAlperen Oz
Alperen Oz
EEEsra Ergin
Esra Ergin
Background: The aim of this study was to assess the microshear bond strength(μSBS) of various adhesive systems on enamel surfaces prepared using either an Er, Cr:YSGG laser or a conventional diamond bur. Methods: Twenty-eight caries-free human molars were longitudinally sectioned, resulting in 56 samples. Buccal or lingual surfaces were embedded in acrylic blocks. Enamel surfaces were prepared using either an Er, Cr: YSGG laser (Biolase Technologies, USA) or a traditional diamond bur (Diatech, Switzerland), referencing the midline of each tooth. Laser treatment was applied to the left side, while the right half underwent bur treatment. The samples were randomly separated into four groups(n=14): [G1] Optibond FL (Kerr, USA), a three-step etch-and-rinse adhesive; [G2] Clearfil SE Bond(Kuraray,Japan), a two-step self-etch adhesive; [G3]Prime&Bond Universal(Dentsply,USA),universal-adhesive/etch-and-rinse-mode; and [G4]Prime&Bond Universal(Dentsply,USA),universal-adhesive/self-etch-mode. Composite cylinders with a diameter of 0.8 mm (Harmonize, Kerr, USA) were affixed to the center of both the laser-prepared and bur-prepared regions of all specimens. The adhesive interface of one randomly chosen representative from each group was analyzed using a Scanning Electron Microscope(SEM). The remaining samples were subjected to μSBS testing. Data were analyzed statistically using Two-Way ANOVA(p0.05). Regardless of the preparation modalities, the adhesive systems did not exhibit any statistically significant differences(p>0.05). Furthermore, the correlation between various adhesive systems and preparation techniques did not result in statistically significant variations in μSBS values(p>0.05). Conclusion: The measured μSBS values of the adhesive systems examined on enamel surfaces prepared using either an Er, Cr:YSGG laser or a diamond bur showed similarity. Keywords: Laser preparation, Microshear bond strength, Scanning electron microscopy, Universal adhesive.

29 April 2026 in Clinical Dentistry and Research
Verified
Journal Article
Closed access
MPMeltem Nermin Polan
Meltem Nermin Polan
GAGulnaz Aydemir
Gulnaz Aydemir
AYA. Rüya Yazıcı
A. Rüya Yazıcı
Background and Aim: To assess the impacts of various energydrinks on the color stability and surface roughness of nanohybridand microhybrid resin-based composites.Materials and Methods: A total of 120 disc-shapedsamples were fabricated using nanohybrid and microhybridcomposite resins. The samples were randomly distributed into6 experimental groups according to the beverage used forimmersion (n=10): Distilled Water (control), Black Bruin, BlackEagle, Burn, Just Power, and Red Bull. Initial surface roughness(Ra) values were measured utilizing a contact profilometer, whilecolor measurements were recorded with a spectrophotometer.After a 7-day immersion period, both surface roughness and colorassessments were repeated. Statistical analysis was conductedusing two-way ANOVA and Tukey’s post hoc test.Results: No statistically difference in color change (ΔE00) wasnoted between nanohybrid and microhybrid composites afterbeverage immersion. Only the Burn group exhibited clinicallyunacceptable ΔE00 values (ΔE00>1.8). Among all groups, Burnresulted in the most significant discoloration (p < 0.05), thoughthis effect was not statistically distinct from Red Bull in themicrohybrid group (p > 0.05). All energy drinks led to increasedsurface roughness in microhybrid resins while Black Eagle,Burn, and Just Power caused significant roughness increasesin the nanohybrid specimens (p < 0.05). The Black Eagle groupdemonstrated higher roughness values in microhybrid resinsthan in nanohybrid ones (p < 0.05).Conclusion: All tested energy drinks increased the surfaceroughness of microhybrid composites, whereas significantchanges in nanohybrid composites were limited to specificgroups. No significant difference in color change was observedbetween the two composite types.